[术前飞秒激光辅助碎裂软晶状体核抽吸手术技术]。

Q3 Medicine Vestnik oftalmologii Pub Date : 2024-01-01 DOI:10.17116/oftalma2024140022109
Yu N Yusef, S N Yusef, A S Vvedenskiy, M N Ivanov, L Alkharki, N D Fokina
{"title":"[术前飞秒激光辅助碎裂软晶状体核抽吸手术技术]。","authors":"Yu N Yusef, S N Yusef, A S Vvedenskiy, M N Ivanov, L Alkharki, N D Fokina","doi":"10.17116/oftalma2024140022109","DOIUrl":null,"url":null,"abstract":"<p><p>Fragmentation and aspiration of soft cataracts require different surgical techniques and approaches compared to the removal of dense nuclei, including when using a femtosecond laser.</p><p><strong>Purpose: </strong>This study was conducted to develop a non-ultrasound technique for aspiration of a soft lens nucleus after its preliminary femtosecond laser-assisted fragmentation.</p><p><strong>Material and methods: </strong>The study included 63 patients (63 eyes) aged 23 to 40 years who underwent surgery. In 27 cases, early or immature cataract was observed, and in 36 cases, cataract removal was performed for refractive purposes in high myopia and complex myopic astigmatism. The VICTUS femtosecond laser surgical system (Technolas Perfect Vision GmbH, Germany) was used for preliminary fragmentation of the lens nucleus. Surgeries were performed using the Centurion Vision System phacoemulsifier (Alcon Laboratories, Inc., USA). The volume of the required irrigation solution was evaluated during the surgery. Intraoperative and postoperative complications were assessed.</p><p><strong>Results: </strong>The surgery was performed without complications in all cases. Capsulorhexis edge was completely preserved along its entire circumference. The study showed the fundamental possibility of aspirating a cataract with a nucleus of grade I-II density without low-frequency ultrasound after preliminary femtosecond laser-assisted fragmentation of the nucleus with a \"grid\" pattern, which ensures minimal fragment size in the central zone of the nucleus. The volume of irrigation solution required for aspiration of the nucleus was 36.0 (27.0; 44.0) ml, which does not significantly differ from the volume of solution during ultrasound phacoemulsification of a nucleus of such density.</p><p><strong>Conclusions: </strong>Femtosecond laser-assisted fragmentation of the lens nucleus with a \"grid\" pattern and phacoemulsifier systems with a high vacuum level allow effective aspiration of a soft lens without using low-frequency ultrasound.</p>","PeriodicalId":23529,"journal":{"name":"Vestnik oftalmologii","volume":"140 2. Vyp. 2","pages":"109-115"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Surgical technique for aspiration of soft lens nucleus with preoperative femtosecond laser-assisted fragmentation].\",\"authors\":\"Yu N Yusef, S N Yusef, A S Vvedenskiy, M N Ivanov, L Alkharki, N D Fokina\",\"doi\":\"10.17116/oftalma2024140022109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fragmentation and aspiration of soft cataracts require different surgical techniques and approaches compared to the removal of dense nuclei, including when using a femtosecond laser.</p><p><strong>Purpose: </strong>This study was conducted to develop a non-ultrasound technique for aspiration of a soft lens nucleus after its preliminary femtosecond laser-assisted fragmentation.</p><p><strong>Material and methods: </strong>The study included 63 patients (63 eyes) aged 23 to 40 years who underwent surgery. In 27 cases, early or immature cataract was observed, and in 36 cases, cataract removal was performed for refractive purposes in high myopia and complex myopic astigmatism. The VICTUS femtosecond laser surgical system (Technolas Perfect Vision GmbH, Germany) was used for preliminary fragmentation of the lens nucleus. Surgeries were performed using the Centurion Vision System phacoemulsifier (Alcon Laboratories, Inc., USA). The volume of the required irrigation solution was evaluated during the surgery. Intraoperative and postoperative complications were assessed.</p><p><strong>Results: </strong>The surgery was performed without complications in all cases. Capsulorhexis edge was completely preserved along its entire circumference. The study showed the fundamental possibility of aspirating a cataract with a nucleus of grade I-II density without low-frequency ultrasound after preliminary femtosecond laser-assisted fragmentation of the nucleus with a \\\"grid\\\" pattern, which ensures minimal fragment size in the central zone of the nucleus. The volume of irrigation solution required for aspiration of the nucleus was 36.0 (27.0; 44.0) ml, which does not significantly differ from the volume of solution during ultrasound phacoemulsification of a nucleus of such density.</p><p><strong>Conclusions: </strong>Femtosecond laser-assisted fragmentation of the lens nucleus with a \\\"grid\\\" pattern and phacoemulsifier systems with a high vacuum level allow effective aspiration of a soft lens without using low-frequency ultrasound.</p>\",\"PeriodicalId\":23529,\"journal\":{\"name\":\"Vestnik oftalmologii\",\"volume\":\"140 2. Vyp. 2\",\"pages\":\"109-115\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik oftalmologii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17116/oftalma2024140022109\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik oftalmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/oftalma2024140022109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

软性白内障的碎裂和吸除与致密晶状体核的摘除相比,需要不同的手术技巧和方法,包括在使用飞秒激光时。目的:本研究旨在开发一种非超声技术,用于在飞秒激光辅助下初步碎裂软晶状体核后进行吸除:研究对象包括 63 名接受手术的患者(63 眼),年龄在 23 至 40 岁之间。其中 27 例为早期白内障或未成熟白内障,36 例为高度近视和复杂近视散光的屈光性白内障摘除术。VICTUS 飞秒激光手术系统(Technolas Perfect Vision GmbH,德国)用于初步破碎晶状体核。手术使用 Centurion Vision 系统超声乳化仪(美国 Alcon 实验室公司)进行。手术过程中对所需灌洗液的容量进行了评估。对术中和术后并发症进行了评估:结果:所有病例的手术均无并发症。所有病例的手术均未出现并发症,囊口边缘在整个圆周上都得到了完全保留。研究表明,在飞秒激光辅助下以 "网格 "模式初步碎核之后,无需低频超声波即可吸出具有 I-II 级密度的核的白内障,从而确保核中心区的碎核体积最小。吸出晶体核所需的灌洗液量为36.0 (27.0; 44.0) ml,与超声乳化这种密度的晶体核时的灌洗液量没有明显差别:结论:飞秒激光辅助的 "网格 "模式晶状体核碎裂和高真空度的超声乳化系统可以在不使用低频超声的情况下有效抽吸软晶状体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Surgical technique for aspiration of soft lens nucleus with preoperative femtosecond laser-assisted fragmentation].

Fragmentation and aspiration of soft cataracts require different surgical techniques and approaches compared to the removal of dense nuclei, including when using a femtosecond laser.

Purpose: This study was conducted to develop a non-ultrasound technique for aspiration of a soft lens nucleus after its preliminary femtosecond laser-assisted fragmentation.

Material and methods: The study included 63 patients (63 eyes) aged 23 to 40 years who underwent surgery. In 27 cases, early or immature cataract was observed, and in 36 cases, cataract removal was performed for refractive purposes in high myopia and complex myopic astigmatism. The VICTUS femtosecond laser surgical system (Technolas Perfect Vision GmbH, Germany) was used for preliminary fragmentation of the lens nucleus. Surgeries were performed using the Centurion Vision System phacoemulsifier (Alcon Laboratories, Inc., USA). The volume of the required irrigation solution was evaluated during the surgery. Intraoperative and postoperative complications were assessed.

Results: The surgery was performed without complications in all cases. Capsulorhexis edge was completely preserved along its entire circumference. The study showed the fundamental possibility of aspirating a cataract with a nucleus of grade I-II density without low-frequency ultrasound after preliminary femtosecond laser-assisted fragmentation of the nucleus with a "grid" pattern, which ensures minimal fragment size in the central zone of the nucleus. The volume of irrigation solution required for aspiration of the nucleus was 36.0 (27.0; 44.0) ml, which does not significantly differ from the volume of solution during ultrasound phacoemulsification of a nucleus of such density.

Conclusions: Femtosecond laser-assisted fragmentation of the lens nucleus with a "grid" pattern and phacoemulsifier systems with a high vacuum level allow effective aspiration of a soft lens without using low-frequency ultrasound.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Vestnik oftalmologii
Vestnik oftalmologii Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
129
期刊介绍: The journal publishes materials on the diagnosis and treatment of eye diseases, hygiene of vision, prevention of ophthalmic affections, history of Russian ophthalmology, organization of ophthalmological aid to the population, as well as the problems of special equipment. Original scientific articles and surveys on urgent problems of theory and practice of Russian and foreign ophthalmology are published. The journal contains book reviews on ophthalmology, information on the activities of ophthalmologists" scientific societies, chronicle of congresses and conferences.The journal is intended for ophthalmologists and scientific workers dealing with clinical problems of diseases of the eye and physiology of vision.
期刊最新文献
[Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens]. [Subfamily of betaherpesviruses as a cause of epithelial and stromal keratitis]. [Terson syndrome and acute myeloid leukemia (case report)]. [The association between myopia and glaucoma]. [The effect of pleoptic treatment on the stability of visual fixation in children and adolescents with amblyopia of various degrees].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1