BT-50 运输装置的性能评估和用户体验,带自动和计划质量控制测量功能。

IF 3.8 2区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY Clinical chemistry and laboratory medicine Pub Date : 2024-05-17 DOI:10.1515/cclm-2024-0220
Minori Tabata, Rie Nakai, Kyoko Kajihara, Hiromi Nakagawa, Shinichi Yamasaki, Fumiaki Hayashi, Sho Mokuda
{"title":"BT-50 运输装置的性能评估和用户体验,带自动和计划质量控制测量功能。","authors":"Minori Tabata, Rie Nakai, Kyoko Kajihara, Hiromi Nakagawa, Shinichi Yamasaki, Fumiaki Hayashi, Sho Mokuda","doi":"10.1515/cclm-2024-0220","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Even in the current era of hematology analyzer automation and peripheral equipment, quality control sample measurement remains a manual task, leading to variability in quality control data and increased workload. In this study, we evaluated the performance of quality control measurement using the BT-50 Transportation Unit (BT-50, Sysmex, Kobe, Japan), equipped with a scheduled automatic quality control function, to ensure measurement accuracy and streamline the workflow of hematology testing.</p><p><strong>Methods: </strong>We evaluated the automatic measurement performance of quality control samples using the BT-50 for six representative blood test parameters: WBC (white blood cell), RBC (red blood cell), HGB (hemoglobin), HCT (hematocrit), PLT (platelet), and RET% (reticulocyte percent). We evaluated the equivalence and compared measurement accuracy between the BT-50 and the manual method. We then compared the variability to other laboratories and confirmed the stability of quality control samples. We also evaluated changes in workflow and staff resources before and after the introduction of the BT-50.</p><p><strong>Results: </strong>The quality control measurement results for the BT-50 and the manual method were found to be equivalent for all six parameters. The variability measured by the BT-50 was lower for some parameters compared to the manual method. Furthermore, the workflow was streamlined by reducing manual processes, resulting in increased efficiency.</p><p><strong>Conclusions: </strong>We confirmed the performance of quality control measurements using the schedule function of the BT-50. Introducing the BT-50 reduced the operator's workload, improved operational efficiency, and promoted the standardization of quality control measurements.</p>","PeriodicalId":10390,"journal":{"name":"Clinical chemistry and laboratory medicine","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation and user experience of BT-50 transportation unit with automated and scheduled quality control measurements.\",\"authors\":\"Minori Tabata, Rie Nakai, Kyoko Kajihara, Hiromi Nakagawa, Shinichi Yamasaki, Fumiaki Hayashi, Sho Mokuda\",\"doi\":\"10.1515/cclm-2024-0220\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Even in the current era of hematology analyzer automation and peripheral equipment, quality control sample measurement remains a manual task, leading to variability in quality control data and increased workload. In this study, we evaluated the performance of quality control measurement using the BT-50 Transportation Unit (BT-50, Sysmex, Kobe, Japan), equipped with a scheduled automatic quality control function, to ensure measurement accuracy and streamline the workflow of hematology testing.</p><p><strong>Methods: </strong>We evaluated the automatic measurement performance of quality control samples using the BT-50 for six representative blood test parameters: WBC (white blood cell), RBC (red blood cell), HGB (hemoglobin), HCT (hematocrit), PLT (platelet), and RET% (reticulocyte percent). We evaluated the equivalence and compared measurement accuracy between the BT-50 and the manual method. We then compared the variability to other laboratories and confirmed the stability of quality control samples. We also evaluated changes in workflow and staff resources before and after the introduction of the BT-50.</p><p><strong>Results: </strong>The quality control measurement results for the BT-50 and the manual method were found to be equivalent for all six parameters. The variability measured by the BT-50 was lower for some parameters compared to the manual method. Furthermore, the workflow was streamlined by reducing manual processes, resulting in increased efficiency.</p><p><strong>Conclusions: </strong>We confirmed the performance of quality control measurements using the schedule function of the BT-50. Introducing the BT-50 reduced the operator's workload, improved operational efficiency, and promoted the standardization of quality control measurements.</p>\",\"PeriodicalId\":10390,\"journal\":{\"name\":\"Clinical chemistry and laboratory medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical chemistry and laboratory medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/cclm-2024-0220\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical chemistry and laboratory medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/cclm-2024-0220","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:即使在血液分析仪自动化和外围设备普及的今天,样本的质量控制测量仍然是一项人工任务,这导致了质量控制数据的不稳定性和工作量的增加。在这项研究中,我们评估了配备预定自动质控功能的 BT-50 运输装置(BT-50,Sysmex,日本神户)的质控测量性能,以确保测量的准确性并简化血液学检验的工作流程:我们评估了使用 BT-50 对六个代表性血液检验参数进行质控样本自动测量的性能:WBC(白细胞)、RBC(红细胞)、HGB(血红蛋白)、HCT(血细胞比容)、PLT(血小板)和 RET%(网织红细胞百分比)。我们评估了 BT-50 和手动方法之间的等效性并比较了测量的准确性。然后,我们与其他实验室的变异性进行了比较,并确认了质控样本的稳定性。我们还评估了引入 BT-50 前后工作流程和人力资源的变化:结果:BT-50 和人工方法的质控测量结果在所有六个参数上都相当。与手动方法相比,BT-50 测量的某些参数的变异性更低。此外,通过减少手工操作,简化了工作流程,提高了效率:我们确认了使用 BT-50 的计划功能进行质量控制测量的性能。引进 BT-50 减少了操作员的工作量,提高了操作效率,促进了质量控制测量的标准化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance evaluation and user experience of BT-50 transportation unit with automated and scheduled quality control measurements.

Objectives: Even in the current era of hematology analyzer automation and peripheral equipment, quality control sample measurement remains a manual task, leading to variability in quality control data and increased workload. In this study, we evaluated the performance of quality control measurement using the BT-50 Transportation Unit (BT-50, Sysmex, Kobe, Japan), equipped with a scheduled automatic quality control function, to ensure measurement accuracy and streamline the workflow of hematology testing.

Methods: We evaluated the automatic measurement performance of quality control samples using the BT-50 for six representative blood test parameters: WBC (white blood cell), RBC (red blood cell), HGB (hemoglobin), HCT (hematocrit), PLT (platelet), and RET% (reticulocyte percent). We evaluated the equivalence and compared measurement accuracy between the BT-50 and the manual method. We then compared the variability to other laboratories and confirmed the stability of quality control samples. We also evaluated changes in workflow and staff resources before and after the introduction of the BT-50.

Results: The quality control measurement results for the BT-50 and the manual method were found to be equivalent for all six parameters. The variability measured by the BT-50 was lower for some parameters compared to the manual method. Furthermore, the workflow was streamlined by reducing manual processes, resulting in increased efficiency.

Conclusions: We confirmed the performance of quality control measurements using the schedule function of the BT-50. Introducing the BT-50 reduced the operator's workload, improved operational efficiency, and promoted the standardization of quality control measurements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical chemistry and laboratory medicine
Clinical chemistry and laboratory medicine 医学-医学实验技术
CiteScore
11.30
自引率
16.20%
发文量
306
审稿时长
3 months
期刊介绍: Clinical Chemistry and Laboratory Medicine (CCLM) publishes articles on novel teaching and training methods applicable to laboratory medicine. CCLM welcomes contributions on the progress in fundamental and applied research and cutting-edge clinical laboratory medicine. It is one of the leading journals in the field, with an impact factor over 3. CCLM is issued monthly, and it is published in print and electronically. CCLM is the official journal of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and publishes regularly EFLM recommendations and news. CCLM is the official journal of the National Societies from Austria (ÖGLMKC); Belgium (RBSLM); Germany (DGKL); Hungary (MLDT); Ireland (ACBI); Italy (SIBioC); Portugal (SPML); and Slovenia (SZKK); and it is affiliated to AACB (Australia) and SFBC (France). Topics: - clinical biochemistry - clinical genomics and molecular biology - clinical haematology and coagulation - clinical immunology and autoimmunity - clinical microbiology - drug monitoring and analysis - evaluation of diagnostic biomarkers - disease-oriented topics (cardiovascular disease, cancer diagnostics, diabetes) - new reagents, instrumentation and technologies - new methodologies - reference materials and methods - reference values and decision limits - quality and safety in laboratory medicine - translational laboratory medicine - clinical metrology Follow @cclm_degruyter on Twitter!
期刊最新文献
A vision to the future: value-based laboratory medicine Inaccuracy definition of Bence Jones proteinuria in the EFLM Urinalysis Guideline 2023. Construction of platelet count-optical method reflex test rules using Micro-RBC#, Macro-RBC%, "PLT clumps?" flag, and "PLT abnormal histogram" flag on the Mindray BC-6800plus hematology analyzer in clinical practice. Why is single sample rule out of non-ST elevation myocardial infarction using high-sensitivity cardiac troponin T safe when analytical imprecision is so high? A joint statistical and clinical demonstration. Circulating tumor DNA measurement: a new pillar of medical oncology?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1