PET/CT 在对 SSTR2 受体表达的各种肿瘤进行粒子治疗规划中的价值:观察者间比较研究

Cancers Pub Date : 2024-05-15 DOI:10.3390/cancers16101877
C. Lütgendorf-Caucig, Patricia Wieland, Eugen Hug, Birgit Flechl, S. Tubin, R. Galalae, Petra Georg, P. Fossati, M. Mumot, S. Harrabi, Irina Pradler, M. Pelak
{"title":"PET/CT 在对 SSTR2 受体表达的各种肿瘤进行粒子治疗规划中的价值:观察者间比较研究","authors":"C. Lütgendorf-Caucig, Patricia Wieland, Eugen Hug, Birgit Flechl, S. Tubin, R. Galalae, Petra Georg, P. Fossati, M. Mumot, S. Harrabi, Irina Pradler, M. Pelak","doi":"10.3390/cancers16101877","DOIUrl":null,"url":null,"abstract":"The overexpression of somatostatin receptor type 2 (SSTR2) is a property of various tumor types. Hybrid imaging utilizing [68Ga]1,4,7,10-tetraazacyclododecane-1,4,7,10-tetra-acetic acid (DOTA) may improve the differentiation between tumor and healthy tissue. We conducted an experimental study on 47 anonymized patient cases including 30 meningiomas, 12 PitNET and 5 SBPGL. Four independent observers were instructed to contour the macroscopic tumor volume on planning MRI and then reassess their volumes with the additional information from DOTA-PET/CT. The conformity between observers and reference volumes was assessed. In total, 46 cases (97.9%) were DOTA-avid and included in the final analysis. In eight cases, PET/CT additional tumor volume was identified that was not detected by MRI; these PET/CT findings were potentially critical for the treatment plan in four cases. For meningiomas, the interobserver and observer to reference volume conformity indices were higher with PET/CT. For PitNET, the volumes had higher conformity between observers with MRI. With regard to SBGDL, no significant trend towards conformity with the addition of PET/CT information was observed. DOTA PET/CT supports accurate tumor recognition in meningioma and PitNET and is recommended in SSTR2-expressing tumors planned for treatment with highly conformal radiation.","PeriodicalId":504676,"journal":{"name":"Cancers","volume":"57 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Value of PET/CT in Particle Therapy Planning of Various Tumors with SSTR2 Receptor Expression: Comparative Interobserver Study\",\"authors\":\"C. Lütgendorf-Caucig, Patricia Wieland, Eugen Hug, Birgit Flechl, S. Tubin, R. Galalae, Petra Georg, P. Fossati, M. Mumot, S. Harrabi, Irina Pradler, M. Pelak\",\"doi\":\"10.3390/cancers16101877\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The overexpression of somatostatin receptor type 2 (SSTR2) is a property of various tumor types. Hybrid imaging utilizing [68Ga]1,4,7,10-tetraazacyclododecane-1,4,7,10-tetra-acetic acid (DOTA) may improve the differentiation between tumor and healthy tissue. We conducted an experimental study on 47 anonymized patient cases including 30 meningiomas, 12 PitNET and 5 SBPGL. Four independent observers were instructed to contour the macroscopic tumor volume on planning MRI and then reassess their volumes with the additional information from DOTA-PET/CT. The conformity between observers and reference volumes was assessed. In total, 46 cases (97.9%) were DOTA-avid and included in the final analysis. In eight cases, PET/CT additional tumor volume was identified that was not detected by MRI; these PET/CT findings were potentially critical for the treatment plan in four cases. For meningiomas, the interobserver and observer to reference volume conformity indices were higher with PET/CT. For PitNET, the volumes had higher conformity between observers with MRI. With regard to SBGDL, no significant trend towards conformity with the addition of PET/CT information was observed. DOTA PET/CT supports accurate tumor recognition in meningioma and PitNET and is recommended in SSTR2-expressing tumors planned for treatment with highly conformal radiation.\",\"PeriodicalId\":504676,\"journal\":{\"name\":\"Cancers\",\"volume\":\"57 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cancers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/cancers16101877\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/cancers16101877","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

体生长抑素受体 2 型(SSTR2)的过度表达是各种肿瘤类型的一个特性。利用[68Ga]1,4,7,10-四氮杂环十二烷-1,4,7,10-四乙酸(DOTA)进行混合成像可提高肿瘤和健康组织的区分度。我们对 47 例匿名患者进行了实验研究,其中包括 30 例脑膜瘤、12 例 PitNET 和 5 例 SBPGL。四名独立的观察者被要求在计划核磁共振成像上勾画宏观肿瘤体积,然后根据 DOTA-PET/CT 的附加信息重新评估其体积。对观察者与参考体积之间的一致性进行了评估。共有 46 个病例(97.9%)与 DOTA 相关并纳入最终分析。在 8 个病例中,PET/CT 发现了核磁共振成像未检测到的额外肿瘤体积;在 4 个病例中,PET/CT 的这些发现可能对治疗计划至关重要。对于脑膜瘤,PET/CT 的观察者之间和观察者与参考容积的一致性指数更高。对于 PitNET,MRI 观察者之间的体积一致性更高。至于 SBGDL,在增加 PET/CT 信息后,未观察到明显的一致性趋势。DOTA PET/CT 可准确识别脑膜瘤和 PitNET 中的肿瘤,推荐用于计划采用高适形放射治疗的 SSTR2 表达肿瘤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Value of PET/CT in Particle Therapy Planning of Various Tumors with SSTR2 Receptor Expression: Comparative Interobserver Study
The overexpression of somatostatin receptor type 2 (SSTR2) is a property of various tumor types. Hybrid imaging utilizing [68Ga]1,4,7,10-tetraazacyclododecane-1,4,7,10-tetra-acetic acid (DOTA) may improve the differentiation between tumor and healthy tissue. We conducted an experimental study on 47 anonymized patient cases including 30 meningiomas, 12 PitNET and 5 SBPGL. Four independent observers were instructed to contour the macroscopic tumor volume on planning MRI and then reassess their volumes with the additional information from DOTA-PET/CT. The conformity between observers and reference volumes was assessed. In total, 46 cases (97.9%) were DOTA-avid and included in the final analysis. In eight cases, PET/CT additional tumor volume was identified that was not detected by MRI; these PET/CT findings were potentially critical for the treatment plan in four cases. For meningiomas, the interobserver and observer to reference volume conformity indices were higher with PET/CT. For PitNET, the volumes had higher conformity between observers with MRI. With regard to SBGDL, no significant trend towards conformity with the addition of PET/CT information was observed. DOTA PET/CT supports accurate tumor recognition in meningioma and PitNET and is recommended in SSTR2-expressing tumors planned for treatment with highly conformal radiation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Aurora Kinase A Inhibition Potentiates Platinum and Radiation Cytotoxicity in Non-Small-Cell Lung Cancer Cells and Induces Expression of Alternative Immune Checkpoints Development and Characterization of Syngeneic Orthotopic Transplant Models of Obesity-Responsive Triple-Negative Breast Cancer in C57BL/6J Mice The Effects of Gynecological Tumor Irradiation on the Immune System A Monocentric Analysis of Implantable Ports in Cancer Treatment: Five-Year Efficacy and Safety Evaluation Drug Combination Nanoparticles Containing Gemcitabine and Paclitaxel Enable Orthotopic 4T1 Breast Tumor Regression
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1