用于电网和公用事业应用的太阳能光伏连接准 Z 源逆变器

IF 0.5 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC Journal of Electrical Systems Pub Date : 2024-05-14 DOI:10.52783/jes.3678
Muneeb Ahmad
{"title":"用于电网和公用事业应用的太阳能光伏连接准 Z 源逆变器","authors":"Muneeb Ahmad","doi":"10.52783/jes.3678","DOIUrl":null,"url":null,"abstract":"This paper discusses the use of quasi-Z-source inverters, in utility grid systems. These inverters enhanced dependability and one-stage buck and boost abilities make them appropriate for photovoltaic power conditioning applications. The small signal sate space method utilized for the proposed system using Quasi ZSI for utility and grid integration application. Shoot through state also implemented on dc side to enhanced the voltage gain. The Controlling of dc side and ac side also implemented in MATLAB using state space transfer function. A two-stage controlling technique implemented on two level 6 switch inverters with SPWM with P & O MPPT and PI controller. The proposed system has solar PV array rating of 5.5kW and utilized in distribution purpose. A simple boost controlling technique has been implemented to obtained the desired gain and less ripples are present in the current due to the presence of inductor in the QZSI impedance network. During light loading the surplus power injected to the grid with the help of PLL system and when load demand increases the power take from the grid smoothly without loss of synchronism. The system has better stability and fast dynamic response during transient. The THD has been observed at the inverter and load side with LC filter, THD within the permissible limit as per IEEE std 1547. ","PeriodicalId":44451,"journal":{"name":"Journal of Electrical Systems","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Solar Photo Voltaic Connected Quasi Z Source Inverter for Grid and utility Application\",\"authors\":\"Muneeb Ahmad\",\"doi\":\"10.52783/jes.3678\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the use of quasi-Z-source inverters, in utility grid systems. These inverters enhanced dependability and one-stage buck and boost abilities make them appropriate for photovoltaic power conditioning applications. The small signal sate space method utilized for the proposed system using Quasi ZSI for utility and grid integration application. Shoot through state also implemented on dc side to enhanced the voltage gain. The Controlling of dc side and ac side also implemented in MATLAB using state space transfer function. A two-stage controlling technique implemented on two level 6 switch inverters with SPWM with P & O MPPT and PI controller. The proposed system has solar PV array rating of 5.5kW and utilized in distribution purpose. A simple boost controlling technique has been implemented to obtained the desired gain and less ripples are present in the current due to the presence of inductor in the QZSI impedance network. During light loading the surplus power injected to the grid with the help of PLL system and when load demand increases the power take from the grid smoothly without loss of synchronism. The system has better stability and fast dynamic response during transient. The THD has been observed at the inverter and load side with LC filter, THD within the permissible limit as per IEEE std 1547. \",\"PeriodicalId\":44451,\"journal\":{\"name\":\"Journal of Electrical Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52783/jes.3678\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52783/jes.3678","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本文讨论了准 Z 源逆变器在公用电网系统中的应用。这些逆变器具有更高的可靠性和单级降压和升压能力,因此适用于光伏功率调节应用。在市电和电网集成应用中,使用准 ZSI 的拟议系统采用了小信号状态空间法。直流侧还采用了击穿状态,以提高电压增益。直流侧和交流侧的控制也在 MATLAB 中使用状态空间传递函数实现。在两级 6 开关逆变器上采用了两级控制技术,SPWM 搭配 P & O MPPT 和 PI 控制器。拟议系统的太阳能光伏阵列额定功率为 5.5kW,用于配电用途。该系统采用了简单的升压控制技术,以获得所需的增益,并且由于 QZSI 阻抗网络中电感的存在,电流中的纹波较小。在轻载时,借助 PLL 系统将剩余电能注入电网,而当负载需求增加时,则从电网顺利获取电能,不会失去同步性。在瞬态期间,系统具有更好的稳定性和快速的动态响应。逆变器和负载侧的总谐波失真(THD)通过 LC 滤波器进行了观测,总谐波失真(THD)在 IEEE 标准 1547 规定的允许范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Solar Photo Voltaic Connected Quasi Z Source Inverter for Grid and utility Application
This paper discusses the use of quasi-Z-source inverters, in utility grid systems. These inverters enhanced dependability and one-stage buck and boost abilities make them appropriate for photovoltaic power conditioning applications. The small signal sate space method utilized for the proposed system using Quasi ZSI for utility and grid integration application. Shoot through state also implemented on dc side to enhanced the voltage gain. The Controlling of dc side and ac side also implemented in MATLAB using state space transfer function. A two-stage controlling technique implemented on two level 6 switch inverters with SPWM with P & O MPPT and PI controller. The proposed system has solar PV array rating of 5.5kW and utilized in distribution purpose. A simple boost controlling technique has been implemented to obtained the desired gain and less ripples are present in the current due to the presence of inductor in the QZSI impedance network. During light loading the surplus power injected to the grid with the help of PLL system and when load demand increases the power take from the grid smoothly without loss of synchronism. The system has better stability and fast dynamic response during transient. The THD has been observed at the inverter and load side with LC filter, THD within the permissible limit as per IEEE std 1547. 
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Electrical Systems
Journal of Electrical Systems ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
1.10
自引率
25.00%
发文量
0
审稿时长
10 weeks
期刊最新文献
Frequency Domain Backdoor Attacks for Visual Object Tracking Exploring Emotional Intelligence in Jordan’s Artificial Intelligence (AI) Healthcare Adoption: A UTAUT Framework Twitter Based Sentiment Analysis of Russia-Ukraine War Using Machine Learning Predictive Analytics and Machine Learning Applications in the USA for Sustainable Supply Chain Operations and Carbon Footprint Reduction Comparison of Control Strategies of Quasi Z-Source Inverter for Wind Power Generation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1