{"title":"用于电网和公用事业应用的太阳能光伏连接准 Z 源逆变器","authors":"Muneeb Ahmad","doi":"10.52783/jes.3678","DOIUrl":null,"url":null,"abstract":"This paper discusses the use of quasi-Z-source inverters, in utility grid systems. These inverters enhanced dependability and one-stage buck and boost abilities make them appropriate for photovoltaic power conditioning applications. The small signal sate space method utilized for the proposed system using Quasi ZSI for utility and grid integration application. Shoot through state also implemented on dc side to enhanced the voltage gain. The Controlling of dc side and ac side also implemented in MATLAB using state space transfer function. A two-stage controlling technique implemented on two level 6 switch inverters with SPWM with P & O MPPT and PI controller. The proposed system has solar PV array rating of 5.5kW and utilized in distribution purpose. A simple boost controlling technique has been implemented to obtained the desired gain and less ripples are present in the current due to the presence of inductor in the QZSI impedance network. During light loading the surplus power injected to the grid with the help of PLL system and when load demand increases the power take from the grid smoothly without loss of synchronism. The system has better stability and fast dynamic response during transient. The THD has been observed at the inverter and load side with LC filter, THD within the permissible limit as per IEEE std 1547. ","PeriodicalId":44451,"journal":{"name":"Journal of Electrical Systems","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Solar Photo Voltaic Connected Quasi Z Source Inverter for Grid and utility Application\",\"authors\":\"Muneeb Ahmad\",\"doi\":\"10.52783/jes.3678\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the use of quasi-Z-source inverters, in utility grid systems. These inverters enhanced dependability and one-stage buck and boost abilities make them appropriate for photovoltaic power conditioning applications. The small signal sate space method utilized for the proposed system using Quasi ZSI for utility and grid integration application. Shoot through state also implemented on dc side to enhanced the voltage gain. The Controlling of dc side and ac side also implemented in MATLAB using state space transfer function. A two-stage controlling technique implemented on two level 6 switch inverters with SPWM with P & O MPPT and PI controller. The proposed system has solar PV array rating of 5.5kW and utilized in distribution purpose. A simple boost controlling technique has been implemented to obtained the desired gain and less ripples are present in the current due to the presence of inductor in the QZSI impedance network. During light loading the surplus power injected to the grid with the help of PLL system and when load demand increases the power take from the grid smoothly without loss of synchronism. The system has better stability and fast dynamic response during transient. The THD has been observed at the inverter and load side with LC filter, THD within the permissible limit as per IEEE std 1547. \",\"PeriodicalId\":44451,\"journal\":{\"name\":\"Journal of Electrical Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52783/jes.3678\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52783/jes.3678","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
摘要
本文讨论了准 Z 源逆变器在公用电网系统中的应用。这些逆变器具有更高的可靠性和单级降压和升压能力,因此适用于光伏功率调节应用。在市电和电网集成应用中,使用准 ZSI 的拟议系统采用了小信号状态空间法。直流侧还采用了击穿状态,以提高电压增益。直流侧和交流侧的控制也在 MATLAB 中使用状态空间传递函数实现。在两级 6 开关逆变器上采用了两级控制技术,SPWM 搭配 P & O MPPT 和 PI 控制器。拟议系统的太阳能光伏阵列额定功率为 5.5kW,用于配电用途。该系统采用了简单的升压控制技术,以获得所需的增益,并且由于 QZSI 阻抗网络中电感的存在,电流中的纹波较小。在轻载时,借助 PLL 系统将剩余电能注入电网,而当负载需求增加时,则从电网顺利获取电能,不会失去同步性。在瞬态期间,系统具有更好的稳定性和快速的动态响应。逆变器和负载侧的总谐波失真(THD)通过 LC 滤波器进行了观测,总谐波失真(THD)在 IEEE 标准 1547 规定的允许范围内。
Solar Photo Voltaic Connected Quasi Z Source Inverter for Grid and utility Application
This paper discusses the use of quasi-Z-source inverters, in utility grid systems. These inverters enhanced dependability and one-stage buck and boost abilities make them appropriate for photovoltaic power conditioning applications. The small signal sate space method utilized for the proposed system using Quasi ZSI for utility and grid integration application. Shoot through state also implemented on dc side to enhanced the voltage gain. The Controlling of dc side and ac side also implemented in MATLAB using state space transfer function. A two-stage controlling technique implemented on two level 6 switch inverters with SPWM with P & O MPPT and PI controller. The proposed system has solar PV array rating of 5.5kW and utilized in distribution purpose. A simple boost controlling technique has been implemented to obtained the desired gain and less ripples are present in the current due to the presence of inductor in the QZSI impedance network. During light loading the surplus power injected to the grid with the help of PLL system and when load demand increases the power take from the grid smoothly without loss of synchronism. The system has better stability and fast dynamic response during transient. The THD has been observed at the inverter and load side with LC filter, THD within the permissible limit as per IEEE std 1547.