{"title":"用于糖尿病护理的带单向阀位移微泵--在负压下泵送胰岛素的挑战","authors":"Eric Chappel","doi":"10.3390/encyclopedia4020052","DOIUrl":null,"url":null,"abstract":"The displacement micropump with passive check valves is an attractive solution for precise insulin infusion in patients with type I diabetes. Unlike most insulin pumps that push insulin from a cartridge using a piston, a displacement micropump will first pull insulin from the reservoir before infusing it into the patient. This dual sequence introduces new challenges in terms of insulin stability, notably if the reservoir is not pressurized. After an introduction to displacement micropumps and a brief review of the insulin degradation mechanism, micropump design rules are discussed in light of microfluidic theory.","PeriodicalId":504869,"journal":{"name":"Encyclopedia","volume":"16 22","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Displacement Micropump with Check Valves for Diabetes Care—The Challenge of Pumping Insulin at Negative Pressure\",\"authors\":\"Eric Chappel\",\"doi\":\"10.3390/encyclopedia4020052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The displacement micropump with passive check valves is an attractive solution for precise insulin infusion in patients with type I diabetes. Unlike most insulin pumps that push insulin from a cartridge using a piston, a displacement micropump will first pull insulin from the reservoir before infusing it into the patient. This dual sequence introduces new challenges in terms of insulin stability, notably if the reservoir is not pressurized. After an introduction to displacement micropumps and a brief review of the insulin degradation mechanism, micropump design rules are discussed in light of microfluidic theory.\",\"PeriodicalId\":504869,\"journal\":{\"name\":\"Encyclopedia\",\"volume\":\"16 22\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Encyclopedia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/encyclopedia4020052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Encyclopedia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/encyclopedia4020052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
带被动单向阀的位移式微型泵是为 I 型糖尿病患者精确输注胰岛素的一种极具吸引力的解决方案。大多数胰岛素泵都是通过活塞将胰岛素从胰岛素筒中抽出,而位移式微型泵则不同,它首先从储液器中抽出胰岛素,然后才将胰岛素注入患者体内。这种双重顺序给胰岛素的稳定性带来了新的挑战,尤其是在储液器没有加压的情况下。在介绍了位移微泵并简要回顾了胰岛素降解机制之后,我们将根据微流体理论讨论微泵的设计规则。
Displacement Micropump with Check Valves for Diabetes Care—The Challenge of Pumping Insulin at Negative Pressure
The displacement micropump with passive check valves is an attractive solution for precise insulin infusion in patients with type I diabetes. Unlike most insulin pumps that push insulin from a cartridge using a piston, a displacement micropump will first pull insulin from the reservoir before infusing it into the patient. This dual sequence introduces new challenges in terms of insulin stability, notably if the reservoir is not pressurized. After an introduction to displacement micropumps and a brief review of the insulin degradation mechanism, micropump design rules are discussed in light of microfluidic theory.