{"title":"高效薄层色谱法定量测定复方片剂中的硫酸罗格列酮和格列美脲","authors":"A. Sen, Tantul Sarkar, D. Sen, R. Maheshwari, A. Zanwar, Rajesh L. Dumpala","doi":"10.1002/sscp.202400059","DOIUrl":null,"url":null,"abstract":"A combination of fixed dose tablet containing 0.5 mg lobeglitazone sulfate (LBZ) and 1 mg glimepiride (GLM) has demonstrated efficacy in enhancing glycemic control in diabetes. The projected work aimed to develop and validate a high‐performance thin‐layer chromatographic (HPTLC) methodology for the precise quantification of both the drugs in tablet formulations. The HPTLC analysis utilized aluminium plates layered with silica gel 60F254, and the solvent system consisted of ethyl acetate, benzene, and hexane (4:3:1 v/v/v) followed by densitometric scanning at 238 nm. The Rf value was found to be 0.68 ± 0.001 for LBZ and 0.48 ± 0.002 for GLM. The methodology exhibited linearity in the range of 100–2000 ng/band for LBZ and 200–4000 ng/band for GLM, with correlation coefficients of 0.9988 and 0.9981, respectively. Exceptional sensitivity was observed, with detection limits of 23.86 ng/band for LBZ and 58.26 ng/band for GLM, along with quantification limits of 72.32 ng/band for LBZ and 176.55 ng/band for GLM. The method demonstrated precision (% relative standard deviation of peak area < 2) and accuracy (recovery between 97% and 102%). The suggested method is suitable for quantifying both the drugs in tablets, making it useful for routine quality control in laboratories.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative determination of lobeglitazone sulfate and glimepiride in combined tablet by robust high‐performance thin layer chromatographic method\",\"authors\":\"A. Sen, Tantul Sarkar, D. Sen, R. Maheshwari, A. Zanwar, Rajesh L. Dumpala\",\"doi\":\"10.1002/sscp.202400059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A combination of fixed dose tablet containing 0.5 mg lobeglitazone sulfate (LBZ) and 1 mg glimepiride (GLM) has demonstrated efficacy in enhancing glycemic control in diabetes. The projected work aimed to develop and validate a high‐performance thin‐layer chromatographic (HPTLC) methodology for the precise quantification of both the drugs in tablet formulations. The HPTLC analysis utilized aluminium plates layered with silica gel 60F254, and the solvent system consisted of ethyl acetate, benzene, and hexane (4:3:1 v/v/v) followed by densitometric scanning at 238 nm. The Rf value was found to be 0.68 ± 0.001 for LBZ and 0.48 ± 0.002 for GLM. The methodology exhibited linearity in the range of 100–2000 ng/band for LBZ and 200–4000 ng/band for GLM, with correlation coefficients of 0.9988 and 0.9981, respectively. Exceptional sensitivity was observed, with detection limits of 23.86 ng/band for LBZ and 58.26 ng/band for GLM, along with quantification limits of 72.32 ng/band for LBZ and 176.55 ng/band for GLM. The method demonstrated precision (% relative standard deviation of peak area < 2) and accuracy (recovery between 97% and 102%). The suggested method is suitable for quantifying both the drugs in tablets, making it useful for routine quality control in laboratories.\",\"PeriodicalId\":21639,\"journal\":{\"name\":\"SEPARATION SCIENCE PLUS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SEPARATION SCIENCE PLUS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/sscp.202400059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202400059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

含 0.5 毫克硫酸罗格列酮(LBZ)和 1 毫克格列美脲(GLM)的固定剂量片剂组合在加强糖尿病患者的血糖控制方面具有显著疗效。本项目旨在开发和验证一种高效薄层色谱(HPTLC)方法,用于精确定量片剂中的两种药物。HPTLC 分析采用硅胶 60F254 层叠铝板,溶剂系统包括乙酸乙酯、苯和正己烷(4:3:1 v/v/v),然后在 238 纳米波长下进行密度扫描。结果发现,LBZ 的 Rf 值为 0.68 ± 0.001,GLM 为 0.48 ± 0.002。该方法在 LBZ 和 GLM 的线性范围分别为 100-2000 纳克/带和 200-4000 纳克/带,相关系数分别为 0.9988 和 0.9981。灵敏度极高,LBZ 和 GLM 的检出限分别为 23.86 ng/带和 58.26 ng/带,定量限分别为 72.32 ng/带和 176.55 ng/带。该方法具有良好的精密度(峰面积相对标准偏差小于 2%)和准确度(回收率在 97% 至 102% 之间)。该方法适用于片剂中两种药物的定量分析,可用于实验室的常规质量控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quantitative determination of lobeglitazone sulfate and glimepiride in combined tablet by robust high‐performance thin layer chromatographic method
A combination of fixed dose tablet containing 0.5 mg lobeglitazone sulfate (LBZ) and 1 mg glimepiride (GLM) has demonstrated efficacy in enhancing glycemic control in diabetes. The projected work aimed to develop and validate a high‐performance thin‐layer chromatographic (HPTLC) methodology for the precise quantification of both the drugs in tablet formulations. The HPTLC analysis utilized aluminium plates layered with silica gel 60F254, and the solvent system consisted of ethyl acetate, benzene, and hexane (4:3:1 v/v/v) followed by densitometric scanning at 238 nm. The Rf value was found to be 0.68 ± 0.001 for LBZ and 0.48 ± 0.002 for GLM. The methodology exhibited linearity in the range of 100–2000 ng/band for LBZ and 200–4000 ng/band for GLM, with correlation coefficients of 0.9988 and 0.9981, respectively. Exceptional sensitivity was observed, with detection limits of 23.86 ng/band for LBZ and 58.26 ng/band for GLM, along with quantification limits of 72.32 ng/band for LBZ and 176.55 ng/band for GLM. The method demonstrated precision (% relative standard deviation of peak area < 2) and accuracy (recovery between 97% and 102%). The suggested method is suitable for quantifying both the drugs in tablets, making it useful for routine quality control in laboratories.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
SEPARATION SCIENCE PLUS
SEPARATION SCIENCE PLUS CHEMISTRY, ANALYTICAL-
CiteScore
1.90
自引率
9.10%
发文量
111
期刊最新文献
Removal of Residual DNA and Host Cell Proteins for the Purification of Recombinant Staphylokinase Expressed in Escherichia coli Green Analytical Approach for HPLC Method Development for Quantification of Sorafenib and Its Pharmacopeia Impurities: LC–MS/MS Characterization and Toxicity Prediction of Stress Degradation Products A Cartridge Structure Facilitates Clinical Mass Spectrometry Pretreatment and Can be Integrated Into a High‐Throughput Instrument Comparison of Polysaccharide Profiles of Different Seaweeds Based on Ion Chromatography and Ultrahigh‐Performance Liquid Chromatography Quantification of Recycled Polypropylene Stabilizers for Quality Control by Liquid Chromatography–Tandem Mass Spectrometry Using Simple, Fast and Efficient Ultrasonic Extraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1