{"title":"部署全尺寸换流器利用水电站,加强区域间振荡阻尼","authors":"Daniel Fank, Herwig Renner","doi":"10.1049/gtd2.13165","DOIUrl":null,"url":null,"abstract":"<p>Due to the increasing share of inverter-based renewable energy sources and the increased retrofitting of conventional hydropower plants with power electronics, novel possibilities arise for providing damping power in case of occurring inter-area oscillations in power systems. This paper presents a complete model of a variable-speed hydropower plant (VSHP) in a single-machine infinite bus system. The demonstrated analytical model is applied for small-signal stability analysis that contains all relevant converter dynamics and is verified by an additional non-linear time-domain simulation. The damping controller approach located in the full-size converter (FSC) consists of the classical power system stabilizer with additional phase compensation, to which an appropriate wide-area input signal is fed via a phasor measurement unit device. Subsequently, the FSC-VSHP with additional damping algorithm is examined with respect to the significantly higher damping performance with regard to inter-area modes in a three-machine model.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13165","citationCount":"0","resultStr":"{\"title\":\"Deployment of a full-size converter utilised hydropower plant to enhance inter-area oscillation damping\",\"authors\":\"Daniel Fank, Herwig Renner\",\"doi\":\"10.1049/gtd2.13165\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Due to the increasing share of inverter-based renewable energy sources and the increased retrofitting of conventional hydropower plants with power electronics, novel possibilities arise for providing damping power in case of occurring inter-area oscillations in power systems. This paper presents a complete model of a variable-speed hydropower plant (VSHP) in a single-machine infinite bus system. The demonstrated analytical model is applied for small-signal stability analysis that contains all relevant converter dynamics and is verified by an additional non-linear time-domain simulation. The damping controller approach located in the full-size converter (FSC) consists of the classical power system stabilizer with additional phase compensation, to which an appropriate wide-area input signal is fed via a phasor measurement unit device. Subsequently, the FSC-VSHP with additional damping algorithm is examined with respect to the significantly higher damping performance with regard to inter-area modes in a three-machine model.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13165\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13165\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Deployment of a full-size converter utilised hydropower plant to enhance inter-area oscillation damping
Due to the increasing share of inverter-based renewable energy sources and the increased retrofitting of conventional hydropower plants with power electronics, novel possibilities arise for providing damping power in case of occurring inter-area oscillations in power systems. This paper presents a complete model of a variable-speed hydropower plant (VSHP) in a single-machine infinite bus system. The demonstrated analytical model is applied for small-signal stability analysis that contains all relevant converter dynamics and is verified by an additional non-linear time-domain simulation. The damping controller approach located in the full-size converter (FSC) consists of the classical power system stabilizer with additional phase compensation, to which an appropriate wide-area input signal is fed via a phasor measurement unit device. Subsequently, the FSC-VSHP with additional damping algorithm is examined with respect to the significantly higher damping performance with regard to inter-area modes in a three-machine model.