Cara Lunn Shirai, Marianna B Ruzinova, Philip Barber, Elizabeth Bianchi, Julie M Ackerman, Tianjiao Wang, Shilah Parrish, John L Frater
{"title":"验证用于骨髓抽吸涂片的自动铁染色过程。","authors":"Cara Lunn Shirai, Marianna B Ruzinova, Philip Barber, Elizabeth Bianchi, Julie M Ackerman, Tianjiao Wang, Shilah Parrish, John L Frater","doi":"10.1007/s12308-024-00586-7","DOIUrl":null,"url":null,"abstract":"<p><p>The assessment of bone marrow iron stores is typically performed on an aspirate smear slide that has been manually stained by a technologist using a commercially available kit. This approach can contribute to inconsistent results and limit the broad use of iron staining in bone marrow specimens, particularly when laboratories have low staffing and/or high specimen volumes. Here, we describe the adaptation and validation of the Ventana Benchmark automated stainer and iron stain kit for routine clinical use of staining iron in bone marrow aspirate smear slides. We assessed accuracy and precision of the Ventana automated iron staining protocol compared to the Perls Prussian blue manual iron staining index method. Hematopathologists assigned Gale scores and enumerated the percentages of erythroid sideroblasts on paired patient bone marrow aspirate smear slides stained by the automated method and the manual iron staining method. We found a similar level of performance of the Ventana automated iron stain relative to the index manual method (as assessed by Pearson correlation and Bland-Altman analyses). In addition, there was low imprecision between replicates performed via the automated iron stain protocol. We also report superior qualitative findings of the automated method in ease of localization of iron storage, visualization of sideroblasts, and counterstain consistency. Automated iron staining of bone marrow aspirate smear slides performed similarly to the manual method and may allow for accurate routine evaluation of bone marrow iron stores as part of bone marrow analysis.</p>","PeriodicalId":51320,"journal":{"name":"Journal of Hematopathology","volume":" ","pages":"121-128"},"PeriodicalIF":0.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of an automated iron stain process for use with bone marrow aspirate smear slides.\",\"authors\":\"Cara Lunn Shirai, Marianna B Ruzinova, Philip Barber, Elizabeth Bianchi, Julie M Ackerman, Tianjiao Wang, Shilah Parrish, John L Frater\",\"doi\":\"10.1007/s12308-024-00586-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The assessment of bone marrow iron stores is typically performed on an aspirate smear slide that has been manually stained by a technologist using a commercially available kit. This approach can contribute to inconsistent results and limit the broad use of iron staining in bone marrow specimens, particularly when laboratories have low staffing and/or high specimen volumes. Here, we describe the adaptation and validation of the Ventana Benchmark automated stainer and iron stain kit for routine clinical use of staining iron in bone marrow aspirate smear slides. We assessed accuracy and precision of the Ventana automated iron staining protocol compared to the Perls Prussian blue manual iron staining index method. Hematopathologists assigned Gale scores and enumerated the percentages of erythroid sideroblasts on paired patient bone marrow aspirate smear slides stained by the automated method and the manual iron staining method. We found a similar level of performance of the Ventana automated iron stain relative to the index manual method (as assessed by Pearson correlation and Bland-Altman analyses). In addition, there was low imprecision between replicates performed via the automated iron stain protocol. We also report superior qualitative findings of the automated method in ease of localization of iron storage, visualization of sideroblasts, and counterstain consistency. Automated iron staining of bone marrow aspirate smear slides performed similarly to the manual method and may allow for accurate routine evaluation of bone marrow iron stores as part of bone marrow analysis.</p>\",\"PeriodicalId\":51320,\"journal\":{\"name\":\"Journal of Hematopathology\",\"volume\":\" \",\"pages\":\"121-128\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hematopathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12308-024-00586-7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hematopathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12308-024-00586-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
Validation of an automated iron stain process for use with bone marrow aspirate smear slides.
The assessment of bone marrow iron stores is typically performed on an aspirate smear slide that has been manually stained by a technologist using a commercially available kit. This approach can contribute to inconsistent results and limit the broad use of iron staining in bone marrow specimens, particularly when laboratories have low staffing and/or high specimen volumes. Here, we describe the adaptation and validation of the Ventana Benchmark automated stainer and iron stain kit for routine clinical use of staining iron in bone marrow aspirate smear slides. We assessed accuracy and precision of the Ventana automated iron staining protocol compared to the Perls Prussian blue manual iron staining index method. Hematopathologists assigned Gale scores and enumerated the percentages of erythroid sideroblasts on paired patient bone marrow aspirate smear slides stained by the automated method and the manual iron staining method. We found a similar level of performance of the Ventana automated iron stain relative to the index manual method (as assessed by Pearson correlation and Bland-Altman analyses). In addition, there was low imprecision between replicates performed via the automated iron stain protocol. We also report superior qualitative findings of the automated method in ease of localization of iron storage, visualization of sideroblasts, and counterstain consistency. Automated iron staining of bone marrow aspirate smear slides performed similarly to the manual method and may allow for accurate routine evaluation of bone marrow iron stores as part of bone marrow analysis.
期刊介绍:
The Journal of Hematopathology aims at providing pathologists with a special interest in hematopathology with all the information needed to perform modern pathology in evaluating lymphoid tissues and bone marrow. To this end the journal publishes reviews, editorials, comments, original papers, guidelines and protocols, papers on ancillary techniques, and occasional case reports in the fields of the pathology, molecular biology, and clinical features of diseases of the hematopoietic system.
The journal is the unique reference point for all pathologists with an interest in hematopathology. Molecular biologists involved in the expanding field of molecular diagnostics and research on lymphomas and leukemia benefit from the journal, too. Furthermore, the journal is of major interest for hematologists dealing with patients suffering from lymphomas, leukemias, and other diseases.
The journal is unique in its true international character. Especially in the field of hematopathology it is clear that there are huge geographical variations in incidence of diseases. This is not only locally relevant, but due to globalization, relevant for all those involved in the management of patients.