用于高度复杂病例(PADUA ⩾ 10)机器人辅助肾部分切除术的三维虚拟模型。

IF 0.8 Q4 UROLOGY & NEPHROLOGY Urologia Journal Pub Date : 2024-08-01 Epub Date: 2024-05-21 DOI:10.1177/03915603241252905
Antonio Andrea Grosso, Fabrizio Di Maida, Luca Lambertini, Anna Cadenar, Simone Coco, Elena Ciaralli, Vincenzo Salamone, Gianni Vittori, Agostino Tuccio, Andrea Mari, Andrea Minervini
{"title":"用于高度复杂病例(PADUA ⩾ 10)机器人辅助肾部分切除术的三维虚拟模型。","authors":"Antonio Andrea Grosso, Fabrizio Di Maida, Luca Lambertini, Anna Cadenar, Simone Coco, Elena Ciaralli, Vincenzo Salamone, Gianni Vittori, Agostino Tuccio, Andrea Mari, Andrea Minervini","doi":"10.1177/03915603241252905","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare two cohorts of patients submitted to robot-assisted partial nephrectomy (RAPN) for highly-complex renal masses (PADUA ⩾ 10) with versus without the use of 3DVMs.</p><p><strong>Materials and methods: </strong>We screened a prospective consecutive cohort of 152 patients submitted to RAPN with 3DVM and 1264 patients submitted to RAPN without 3DVM between 2019 and 2022. Only PADUA ⩾ 10 cases were considered eligible for analysis. Propensity score matching (PSM) analysis was applied. Primary endpoint was to evaluate whereas RAPNs with 3DVM were superior in terms of functional outcomes at 12-month. Secondary outcomes were to compare perioperative and oncological outcomes. Multivariable logistic regression analyses (MVA) tested the associations of clinically significant eGFR drop and 3DVMs. Subgroups analysis was performed for PAUDA-risk categories.</p><p><strong>Results: </strong>Thirty seven patients for each group were analyzed after PSM. RAPN with 3DVM presented a higher rate of selective/no clamping procedure (32.5% vs 16.2%, <i>p</i> = 0.03) and a higher enucleation rate (43.2% vs 29.8%, <i>p</i> = 0.04). Twelve-month functional preservation performed better within 3DVM group in terms of creatinine serum level (median 1.2 [IQR 1.1-1.4] vs 1.6 [IQR 1.1-1.8], <i>p</i> = 0.03) and eGFR (median 64.6 [IQR 56.2-74.1] vs 52.3 [IQR 49.2-74.1], <i>p</i> = 0.03). MVA confirmed 3DVM as a protective factor for clinically significant eGFR drop in this subgroup of patients.</p><p><strong>Conclusions: </strong>RAPN performed with the use of 3DVM assistance for PADUA ⩾ 10 cases resulted in lower incidence of global ischemia and higher rate of enucleations. The positive impact of such technology was found at 12-month follow-up.</p>","PeriodicalId":23574,"journal":{"name":"Urologia Journal","volume":" ","pages":"568-573"},"PeriodicalIF":0.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"3D virtual model for robot-assisted partial nephrectomy in highly-complex cases (PADUA ⩾ 10).\",\"authors\":\"Antonio Andrea Grosso, Fabrizio Di Maida, Luca Lambertini, Anna Cadenar, Simone Coco, Elena Ciaralli, Vincenzo Salamone, Gianni Vittori, Agostino Tuccio, Andrea Mari, Andrea Minervini\",\"doi\":\"10.1177/03915603241252905\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare two cohorts of patients submitted to robot-assisted partial nephrectomy (RAPN) for highly-complex renal masses (PADUA ⩾ 10) with versus without the use of 3DVMs.</p><p><strong>Materials and methods: </strong>We screened a prospective consecutive cohort of 152 patients submitted to RAPN with 3DVM and 1264 patients submitted to RAPN without 3DVM between 2019 and 2022. Only PADUA ⩾ 10 cases were considered eligible for analysis. Propensity score matching (PSM) analysis was applied. Primary endpoint was to evaluate whereas RAPNs with 3DVM were superior in terms of functional outcomes at 12-month. Secondary outcomes were to compare perioperative and oncological outcomes. Multivariable logistic regression analyses (MVA) tested the associations of clinically significant eGFR drop and 3DVMs. Subgroups analysis was performed for PAUDA-risk categories.</p><p><strong>Results: </strong>Thirty seven patients for each group were analyzed after PSM. RAPN with 3DVM presented a higher rate of selective/no clamping procedure (32.5% vs 16.2%, <i>p</i> = 0.03) and a higher enucleation rate (43.2% vs 29.8%, <i>p</i> = 0.04). Twelve-month functional preservation performed better within 3DVM group in terms of creatinine serum level (median 1.2 [IQR 1.1-1.4] vs 1.6 [IQR 1.1-1.8], <i>p</i> = 0.03) and eGFR (median 64.6 [IQR 56.2-74.1] vs 52.3 [IQR 49.2-74.1], <i>p</i> = 0.03). MVA confirmed 3DVM as a protective factor for clinically significant eGFR drop in this subgroup of patients.</p><p><strong>Conclusions: </strong>RAPN performed with the use of 3DVM assistance for PADUA ⩾ 10 cases resulted in lower incidence of global ischemia and higher rate of enucleations. The positive impact of such technology was found at 12-month follow-up.</p>\",\"PeriodicalId\":23574,\"journal\":{\"name\":\"Urologia Journal\",\"volume\":\" \",\"pages\":\"568-573\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Urologia Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/03915603241252905\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urologia Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/03915603241252905","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较两组因高度复杂肾肿块(PADUA ⩾ 10)而接受机器人辅助肾部分切除术(RAPN)的患者使用 3DVM 与不使用 3DVM 的情况:我们筛选了2019年至2022年期间接受RAPN治疗的152名患者和接受RAPN治疗的1264名患者,这两组患者均使用了3DVM。只有 PADUA ⩾ 10 的病例才符合分析条件。采用倾向评分匹配(PSM)分析。主要终点是评估使用 3DVM 的 RAPNs 在 12 个月的功能结果方面是否更优。次要结果是比较围手术期和肿瘤学结果。多变量逻辑回归分析(MVA)检验了临床上明显的 eGFR 下降与 3DVM 的相关性。对PAUDA风险类别进行了分组分析:经过 PSM 分析,每组有 37 名患者。RAPN与3DVM的选择性/不钳夹率较高(32.5% vs 16.2%,P = 0.03),去核率较高(43.2% vs 29.8%,P = 0.04)。就血清肌酐水平(中位数 1.2 [IQR 1.1-1.4] vs 1.6 [IQR 1.1-1.8],p = 0.03)和 eGFR(中位数 64.6 [IQR 56.2-74.1] vs 52.3 [IQR 49.2-74.1],p = 0.03)而言,3DVM 组的 12 个月功能保存情况更好。MVA证实3DVM是该亚组患者eGFR临床显著下降的保护因素:结论:使用 3DVM 辅助对 PADUA ⩾ 10 例患者进行 RAPN,可降低全身缺血发生率,提高去核率。在 12 个月的随访中发现了该技术的积极影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3D virtual model for robot-assisted partial nephrectomy in highly-complex cases (PADUA ⩾ 10).

Purpose: To compare two cohorts of patients submitted to robot-assisted partial nephrectomy (RAPN) for highly-complex renal masses (PADUA ⩾ 10) with versus without the use of 3DVMs.

Materials and methods: We screened a prospective consecutive cohort of 152 patients submitted to RAPN with 3DVM and 1264 patients submitted to RAPN without 3DVM between 2019 and 2022. Only PADUA ⩾ 10 cases were considered eligible for analysis. Propensity score matching (PSM) analysis was applied. Primary endpoint was to evaluate whereas RAPNs with 3DVM were superior in terms of functional outcomes at 12-month. Secondary outcomes were to compare perioperative and oncological outcomes. Multivariable logistic regression analyses (MVA) tested the associations of clinically significant eGFR drop and 3DVMs. Subgroups analysis was performed for PAUDA-risk categories.

Results: Thirty seven patients for each group were analyzed after PSM. RAPN with 3DVM presented a higher rate of selective/no clamping procedure (32.5% vs 16.2%, p = 0.03) and a higher enucleation rate (43.2% vs 29.8%, p = 0.04). Twelve-month functional preservation performed better within 3DVM group in terms of creatinine serum level (median 1.2 [IQR 1.1-1.4] vs 1.6 [IQR 1.1-1.8], p = 0.03) and eGFR (median 64.6 [IQR 56.2-74.1] vs 52.3 [IQR 49.2-74.1], p = 0.03). MVA confirmed 3DVM as a protective factor for clinically significant eGFR drop in this subgroup of patients.

Conclusions: RAPN performed with the use of 3DVM assistance for PADUA ⩾ 10 cases resulted in lower incidence of global ischemia and higher rate of enucleations. The positive impact of such technology was found at 12-month follow-up.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Urologia Journal
Urologia Journal UROLOGY & NEPHROLOGY-
CiteScore
0.60
自引率
12.50%
发文量
66
期刊最新文献
Risk factors for benign uretero-enteric anastomotic strictures after open radical cystectomy and ileal conduit. On integrative analysis of multi-level gene expression data in Kidney cancer subgrouping. A new approach to repair recurrent vescicourethral anastomotic strictures after radical prostatectomy: The use of prerectal access. Potential value of Prostate Cancer Antigen 3 score in prediction of final cancer pathology parameters in radical prostatectomy patients. Retrograde urethrography (RUG) combined with voiding cystourethrography (VCUG) versus surgical findings in assessment of urethral strictures length.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1