Britanny L Stark, Michelle Gamboa, Aibhlin Esparza, Truman J Cavendar-Word, Diego Bermudez, Luisa Carlon, David A Roberson, Binata Joddar, Sylvia Natividad-Diaz
{"title":"立体光刻三维打印聚合物的材料表征,以开发用于生物分析应用的自驱动微流控装置。","authors":"Britanny L Stark, Michelle Gamboa, Aibhlin Esparza, Truman J Cavendar-Word, Diego Bermudez, Luisa Carlon, David A Roberson, Binata Joddar, Sylvia Natividad-Diaz","doi":"10.1021/acsabm.4c00059","DOIUrl":null,"url":null,"abstract":"<p><p>Stereolithography (SLA) 3D printing is a rapid prototyping technique and reproducible manufacturing platform, which makes it a useful tool to develop advanced microfluidic devices for bioanalytical applications. However, limited information exists regarding the physical, chemical, and biological properties of the photocured polymers printed with SLA. This study demonstrates the characterization of a commercially available SLA 3D printed polymer to evaluate the potential presence of any time-dependent changes in material properties that may affect its ability to produce functional, capillary-action microfluidic devices. The printed polymer was analyzed with Fourier transform infrared-attenuated total reflectance, contact angle measurements, tensile test, impact test, scanning electron microscopy, and fluid flow analysis. Polymer biocompatibility was assessed with propidium iodide flow cytometry and an MTT assay for cell viability. The material characterization and biocompatibility results were then implemented to design and fabricate a self-driven capillary action microfluidic device for future use as a bioanalytical assay. This study demonstrates temporally stable mechanical properties and biocompatibility of the SLA polymer. However, surface characterization through contact angle measurements shows the polymer's wettability changes over time which indicates there is a limited postprinting period when the polymer can be used for capillary-based fluid flow. Overall, this study demonstrates the feasibility of implementing SLA as a high-throughput manufacturing method for capillary action microfluidic devices.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"7883-7894"},"PeriodicalIF":4.6000,"publicationDate":"2024-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Materials Characterization of Stereolithography 3D Printed Polymer to Develop a Self-Driven Microfluidic Device for Bioanalytical Applications.\",\"authors\":\"Britanny L Stark, Michelle Gamboa, Aibhlin Esparza, Truman J Cavendar-Word, Diego Bermudez, Luisa Carlon, David A Roberson, Binata Joddar, Sylvia Natividad-Diaz\",\"doi\":\"10.1021/acsabm.4c00059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Stereolithography (SLA) 3D printing is a rapid prototyping technique and reproducible manufacturing platform, which makes it a useful tool to develop advanced microfluidic devices for bioanalytical applications. However, limited information exists regarding the physical, chemical, and biological properties of the photocured polymers printed with SLA. This study demonstrates the characterization of a commercially available SLA 3D printed polymer to evaluate the potential presence of any time-dependent changes in material properties that may affect its ability to produce functional, capillary-action microfluidic devices. The printed polymer was analyzed with Fourier transform infrared-attenuated total reflectance, contact angle measurements, tensile test, impact test, scanning electron microscopy, and fluid flow analysis. Polymer biocompatibility was assessed with propidium iodide flow cytometry and an MTT assay for cell viability. The material characterization and biocompatibility results were then implemented to design and fabricate a self-driven capillary action microfluidic device for future use as a bioanalytical assay. This study demonstrates temporally stable mechanical properties and biocompatibility of the SLA polymer. However, surface characterization through contact angle measurements shows the polymer's wettability changes over time which indicates there is a limited postprinting period when the polymer can be used for capillary-based fluid flow. Overall, this study demonstrates the feasibility of implementing SLA as a high-throughput manufacturing method for capillary action microfluidic devices.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\" \",\"pages\":\"7883-7894\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1021/acsabm.4c00059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1021/acsabm.4c00059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Materials Characterization of Stereolithography 3D Printed Polymer to Develop a Self-Driven Microfluidic Device for Bioanalytical Applications.
Stereolithography (SLA) 3D printing is a rapid prototyping technique and reproducible manufacturing platform, which makes it a useful tool to develop advanced microfluidic devices for bioanalytical applications. However, limited information exists regarding the physical, chemical, and biological properties of the photocured polymers printed with SLA. This study demonstrates the characterization of a commercially available SLA 3D printed polymer to evaluate the potential presence of any time-dependent changes in material properties that may affect its ability to produce functional, capillary-action microfluidic devices. The printed polymer was analyzed with Fourier transform infrared-attenuated total reflectance, contact angle measurements, tensile test, impact test, scanning electron microscopy, and fluid flow analysis. Polymer biocompatibility was assessed with propidium iodide flow cytometry and an MTT assay for cell viability. The material characterization and biocompatibility results were then implemented to design and fabricate a self-driven capillary action microfluidic device for future use as a bioanalytical assay. This study demonstrates temporally stable mechanical properties and biocompatibility of the SLA polymer. However, surface characterization through contact angle measurements shows the polymer's wettability changes over time which indicates there is a limited postprinting period when the polymer can be used for capillary-based fluid flow. Overall, this study demonstrates the feasibility of implementing SLA as a high-throughput manufacturing method for capillary action microfluidic devices.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.