防止环中瓣或瓣中瓣经导管二尖瓣置换术中左心室流出道阻塞的改良尖对基底 LAMPOON。

IF 1.8 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Acta Cardiologica Sinica Pub Date : 2024-05-01 DOI:10.6515/ACS.202405_40(3).20240129A
Huan-Chiu Lin, Yung-Tsai Lee, Tien-Ping Tsao, Kuo-Chen Lee, Ming-Chon Hsiung, Wei-Hsian Yin, Jeng Wei
{"title":"防止环中瓣或瓣中瓣经导管二尖瓣置换术中左心室流出道阻塞的改良尖对基底 LAMPOON。","authors":"Huan-Chiu Lin, Yung-Tsai Lee, Tien-Ping Tsao, Kuo-Chen Lee, Ming-Chon Hsiung, Wei-Hsian Yin, Jeng Wei","doi":"10.6515/ACS.202405_40(3).20240129A","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN (LAMPOON) procedure may be performed from the leaflet tip to base to prevent left ventricular outflow tract obstruction (LVOTO) in patients with high-risk anatomy undergoing valve-in-valve (VIV) or valve-in-(complete)-ring (VIR) transcatheter mitral valve replacement (TMVR).</p><p><strong>Methods and results: </strong>Thirteen consecutive patients (6 females, average age 67.7 years) with a mean left ventricular ejection fraction of 60%, a median STS score of 3.2%, and degenerative surgical mitral bioprosthesis or ring were treated with a combined, single-stage procedure of preventive LAMPOON and trans-septal TMVR with SAPIEN 3 valves (Edwards Lifesciences, Irvine, CA). Under real-time 3-dimensional transesophageal echocardiography (RT 3D-TEE) guidance, we included the rendezvous technique in the LAMPOON procedure, and all 13 patients were successfully treated by tip-to-base LAMPOON and TMVR. The use of a modified LAMPOON procedure, aided by a rendezvous technique and guided by RT 3D-TEE imaging, offers precise guidance for positioning and aligning the guidewire. This approach not only reduces the need for fluoroscopy and shortens procedure times, but also significantly increases the likelihood of a successful outcome. Importantly, none of the patients in our study experienced unintentional aortic or aortic valve injuries, nor did they develop significant LVOTO following TMVR. In 11 of the 13 (85%) patients, we used a transcatheter SENTINEL<sup>TM</sup> cerebral protection device (Boston Scientific, Marlborough, MA) for stroke prevention and capture of debris ≥ 2 mm were detected in 8/11 (73%) of the cases.</p><p><strong>Conclusions: </strong>Utilizing intra-operative RT 3D-TEE in conjunction with the rendezvous technique can make the tip-to-base LAMPOON procedure even safer and more effective for patients undergoing VIV or VIR TMVR. Our study also suggests that cerebral protection is indicated in patients undergoing TMVR.</p>","PeriodicalId":6957,"journal":{"name":"Acta Cardiologica Sinica","volume":"40 3","pages":"331-339"},"PeriodicalIF":1.8000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11106618/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Modified Tip-to-Base LAMPOON to Prevent Left Ventricular Outflow Tract Obstruction in Valve-in-Ring or Valve-in-Valve Transcatheter Mitral Valve Replacement.\",\"authors\":\"Huan-Chiu Lin, Yung-Tsai Lee, Tien-Ping Tsao, Kuo-Chen Lee, Ming-Chon Hsiung, Wei-Hsian Yin, Jeng Wei\",\"doi\":\"10.6515/ACS.202405_40(3).20240129A\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN (LAMPOON) procedure may be performed from the leaflet tip to base to prevent left ventricular outflow tract obstruction (LVOTO) in patients with high-risk anatomy undergoing valve-in-valve (VIV) or valve-in-(complete)-ring (VIR) transcatheter mitral valve replacement (TMVR).</p><p><strong>Methods and results: </strong>Thirteen consecutive patients (6 females, average age 67.7 years) with a mean left ventricular ejection fraction of 60%, a median STS score of 3.2%, and degenerative surgical mitral bioprosthesis or ring were treated with a combined, single-stage procedure of preventive LAMPOON and trans-septal TMVR with SAPIEN 3 valves (Edwards Lifesciences, Irvine, CA). Under real-time 3-dimensional transesophageal echocardiography (RT 3D-TEE) guidance, we included the rendezvous technique in the LAMPOON procedure, and all 13 patients were successfully treated by tip-to-base LAMPOON and TMVR. The use of a modified LAMPOON procedure, aided by a rendezvous technique and guided by RT 3D-TEE imaging, offers precise guidance for positioning and aligning the guidewire. This approach not only reduces the need for fluoroscopy and shortens procedure times, but also significantly increases the likelihood of a successful outcome. Importantly, none of the patients in our study experienced unintentional aortic or aortic valve injuries, nor did they develop significant LVOTO following TMVR. In 11 of the 13 (85%) patients, we used a transcatheter SENTINEL<sup>TM</sup> cerebral protection device (Boston Scientific, Marlborough, MA) for stroke prevention and capture of debris ≥ 2 mm were detected in 8/11 (73%) of the cases.</p><p><strong>Conclusions: </strong>Utilizing intra-operative RT 3D-TEE in conjunction with the rendezvous technique can make the tip-to-base LAMPOON procedure even safer and more effective for patients undergoing VIV or VIR TMVR. Our study also suggests that cerebral protection is indicated in patients undergoing TMVR.</p>\",\"PeriodicalId\":6957,\"journal\":{\"name\":\"Acta Cardiologica Sinica\",\"volume\":\"40 3\",\"pages\":\"331-339\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11106618/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Cardiologica Sinica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.6515/ACS.202405_40(3).20240129A\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Cardiologica Sinica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.6515/ACS.202405_40(3).20240129A","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:在接受瓣中瓣(VIV)或瓣全环(VIR)经导管二尖瓣置换术(TMVR)的高风险解剖结构患者中,可从瓣叶顶端到基底部实施二尖瓣前叶撕裂术以防止左室流出道梗阻(LVOTO):13 名连续患者(6 名女性,平均年龄 67.7 岁)的平均左心室射血分数为 60%,中位 STS 评分为 3.2%,手术二尖瓣生物瓣膜或瓣环退行性变,他们接受了预防性 LAMPOON 和使用 SAPIEN 3 瓣膜(Edwards Lifesciences,加利福尼亚州欧文市)的经切口 TMVR 的单阶段联合手术治疗。在实时三维经食道超声心动图(RT 3D-TEE)引导下,我们在 LAMPOON 手术中加入了交会技术,所有 13 名患者都成功接受了尖对基底 LAMPOON 和 TMVR 治疗。在交会技术的辅助下,在 RT 3D-TEE 成像的引导下,使用改良的 LAMPOON 手术为定位和对齐导丝提供了精确的引导。这种方法不仅减少了透视需要,缩短了手术时间,还大大提高了手术成功的可能性。重要的是,在我们的研究中,没有一名患者在 TMVR 术后出现主动脉或主动脉瓣意外损伤,也没有出现明显的左心室缺血。在 13 例患者中的 11 例(85%)中,我们使用了经导管 SENTINELTM 脑保护装置(波士顿科学公司,马萨诸塞州马尔伯勒市)来预防中风,在 8/11 例(73%)中检测到碎片捕获量≥ 2 mm:结论:对于接受 VIV 或 VIR TMVR 的患者来说,将术中 RT 3D-TEE 与交会技术相结合可使顶端到基底的 LAMPOON 手术更加安全有效。我们的研究还表明,脑保护适用于接受 TMVR 的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Modified Tip-to-Base LAMPOON to Prevent Left Ventricular Outflow Tract Obstruction in Valve-in-Ring or Valve-in-Valve Transcatheter Mitral Valve Replacement.

Background: The Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN (LAMPOON) procedure may be performed from the leaflet tip to base to prevent left ventricular outflow tract obstruction (LVOTO) in patients with high-risk anatomy undergoing valve-in-valve (VIV) or valve-in-(complete)-ring (VIR) transcatheter mitral valve replacement (TMVR).

Methods and results: Thirteen consecutive patients (6 females, average age 67.7 years) with a mean left ventricular ejection fraction of 60%, a median STS score of 3.2%, and degenerative surgical mitral bioprosthesis or ring were treated with a combined, single-stage procedure of preventive LAMPOON and trans-septal TMVR with SAPIEN 3 valves (Edwards Lifesciences, Irvine, CA). Under real-time 3-dimensional transesophageal echocardiography (RT 3D-TEE) guidance, we included the rendezvous technique in the LAMPOON procedure, and all 13 patients were successfully treated by tip-to-base LAMPOON and TMVR. The use of a modified LAMPOON procedure, aided by a rendezvous technique and guided by RT 3D-TEE imaging, offers precise guidance for positioning and aligning the guidewire. This approach not only reduces the need for fluoroscopy and shortens procedure times, but also significantly increases the likelihood of a successful outcome. Importantly, none of the patients in our study experienced unintentional aortic or aortic valve injuries, nor did they develop significant LVOTO following TMVR. In 11 of the 13 (85%) patients, we used a transcatheter SENTINELTM cerebral protection device (Boston Scientific, Marlborough, MA) for stroke prevention and capture of debris ≥ 2 mm were detected in 8/11 (73%) of the cases.

Conclusions: Utilizing intra-operative RT 3D-TEE in conjunction with the rendezvous technique can make the tip-to-base LAMPOON procedure even safer and more effective for patients undergoing VIV or VIR TMVR. Our study also suggests that cerebral protection is indicated in patients undergoing TMVR.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Cardiologica Sinica
Acta Cardiologica Sinica 医学-心血管系统
CiteScore
2.90
自引率
15.80%
发文量
144
审稿时长
>12 weeks
期刊介绍: Acta Cardiologica Sinica welcomes all the papers in the fields related to cardiovascular medicine including basic research, vascular biology, clinical pharmacology, clinical trial, critical care medicine, coronary artery disease, interventional cardiology, arrythmia and electrophysiology, atherosclerosis, hypertension, cardiomyopathy and heart failure, valvular and structure cardiac disease, pediatric cardiology, cardiovascular surgery, and so on. We received papers from more than 20 countries and areas of the world. Currently, 40% of the papers were submitted to Acta Cardiologica Sinica from Taiwan, 20% from China, and 20% from the other countries and areas in the world. The acceptance rate for publication was around 50% in general.
期刊最新文献
Ten-Year Clinical Progression in a Patient with Fabry Disease: A Longitudinal Study. The Distribution of Left Ventricular Ejection Fraction, Characteristics, and Clinical Outcomes of Patients with Newly Diagnosed Heart Failure in Taiwan. 2023 TSOC-TACVPR-TACPAH Consensus Statement of the Rehabilitation on Patients with Pulmonary Hypertension. 2024 Guidelines of the Taiwan Society of Cardiology on the Primary Prevention of Atherosclerotic Cardiovascular Disease --- Part II. A Case with a Short QT Interval and Idiopathic Ventricular Fibrillation Due to Carnitine Transporter Defect.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1