通过可食用胶囊技术测量的正常胃肠道温度值:系统综述。

Q3 Engineering Journal of Medical Engineering and Technology Pub Date : 2023-11-01 Epub Date: 2024-05-23 DOI:10.1080/03091902.2024.2354793
William Martins Januário, Emille Rocha Bernardino de Almeida Prata, Antônio José Natali, Thales Nicolau Prímola-Gomes
{"title":"通过可食用胶囊技术测量的正常胃肠道温度值:系统综述。","authors":"William Martins Januário, Emille Rocha Bernardino de Almeida Prata, Antônio José Natali, Thales Nicolau Prímola-Gomes","doi":"10.1080/03091902.2024.2354793","DOIUrl":null,"url":null,"abstract":"<p><p>Climate change has amplified the importance of continuous and precise body core temperature (T<sub>core</sub>) monitoring in the everyday life. In this context, assessing T<sub>core</sub> through ingestible capsules technology, i.e., gastrointestinal temperature (T<sub>gastrointestinal</sub>), emerges as a good alternative to prevent heat-related illness. Therefore, we conducted a systematic review to point out values of normal T<sub>gastrointestinal</sub> measured through ingestible capsules in healthy humans. The study followed PRISMA guidelines and searched the PubMed and Scielo databases from 1971 to 2023. Our search strategy included the descriptors (\"gastrointestinal temperature\") AND (\"measurement\"), and eligible studies had to be written in English and measured T<sub>gastrointestinal</sub> using ingestible capsules or sensors in healthy adults aged 18-59 at rest. Two pairs of researchers independently reviewed titles and abstracts and identified 35 relevant articles out of 1,088 in the initial search. An average value of 37.13 °C with a standard deviation of 0.24 °C was observed, independently of the gender. The values measured ranged from 36.70 °C to 37.69 °C. In conclusion, this systematic review pointed out the mean value of 37.13 ± 0.24 °C measured by ingestible capsules as reference for resting T<sub>gastrointestinal</sub> in healthy adult individuals.</p>","PeriodicalId":39637,"journal":{"name":"Journal of Medical Engineering and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Normal gastrointestinal temperature values measured through ingestible capsules technology: a systematic review.\",\"authors\":\"William Martins Januário, Emille Rocha Bernardino de Almeida Prata, Antônio José Natali, Thales Nicolau Prímola-Gomes\",\"doi\":\"10.1080/03091902.2024.2354793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Climate change has amplified the importance of continuous and precise body core temperature (T<sub>core</sub>) monitoring in the everyday life. In this context, assessing T<sub>core</sub> through ingestible capsules technology, i.e., gastrointestinal temperature (T<sub>gastrointestinal</sub>), emerges as a good alternative to prevent heat-related illness. Therefore, we conducted a systematic review to point out values of normal T<sub>gastrointestinal</sub> measured through ingestible capsules in healthy humans. The study followed PRISMA guidelines and searched the PubMed and Scielo databases from 1971 to 2023. Our search strategy included the descriptors (\\\"gastrointestinal temperature\\\") AND (\\\"measurement\\\"), and eligible studies had to be written in English and measured T<sub>gastrointestinal</sub> using ingestible capsules or sensors in healthy adults aged 18-59 at rest. Two pairs of researchers independently reviewed titles and abstracts and identified 35 relevant articles out of 1,088 in the initial search. An average value of 37.13 °C with a standard deviation of 0.24 °C was observed, independently of the gender. The values measured ranged from 36.70 °C to 37.69 °C. In conclusion, this systematic review pointed out the mean value of 37.13 ± 0.24 °C measured by ingestible capsules as reference for resting T<sub>gastrointestinal</sub> in healthy adult individuals.</p>\",\"PeriodicalId\":39637,\"journal\":{\"name\":\"Journal of Medical Engineering and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Engineering and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/03091902.2024.2354793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/03091902.2024.2354793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

气候变化凸显了在日常生活中持续、精确监测人体核心温度(Tcore)的重要性。在这种情况下,通过可摄入胶囊技术评估核心体温,即胃肠道体温(Tgastrointestinal),成为预防热相关疾病的一种良好替代方法。因此,我们进行了一项系统综述,以指出通过可食用胶囊测量健康人正常胃肠道温度的值。本研究遵循 PRISMA 指南,检索了 1971 年至 2023 年的 PubMed 和 Scielo 数据库。我们的搜索策略包括描述符("胃肠道温度")和("测量"),符合条件的研究必须以英语撰写,并在 18-59 岁的健康成年人中使用可食用胶囊或传感器测量休息时的胃肠道温度。两对研究人员独立审阅了标题和摘要,并从最初搜索的 1,088 篇文章中确定了 35 篇相关文章。观察到的平均值为 37.13 °C,标准偏差为 0.24 °C,与性别无关。测量值范围为 36.70 ℃ 至 37.69 ℃。总之,本系统综述指出,健康成年人的静息胃肠道温度参考值为 37.13 ± 0.24 °C,由可食用胶囊测量得出的平均值为 37.13 ± 0.24 °C。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Normal gastrointestinal temperature values measured through ingestible capsules technology: a systematic review.

Climate change has amplified the importance of continuous and precise body core temperature (Tcore) monitoring in the everyday life. In this context, assessing Tcore through ingestible capsules technology, i.e., gastrointestinal temperature (Tgastrointestinal), emerges as a good alternative to prevent heat-related illness. Therefore, we conducted a systematic review to point out values of normal Tgastrointestinal measured through ingestible capsules in healthy humans. The study followed PRISMA guidelines and searched the PubMed and Scielo databases from 1971 to 2023. Our search strategy included the descriptors ("gastrointestinal temperature") AND ("measurement"), and eligible studies had to be written in English and measured Tgastrointestinal using ingestible capsules or sensors in healthy adults aged 18-59 at rest. Two pairs of researchers independently reviewed titles and abstracts and identified 35 relevant articles out of 1,088 in the initial search. An average value of 37.13 °C with a standard deviation of 0.24 °C was observed, independently of the gender. The values measured ranged from 36.70 °C to 37.69 °C. In conclusion, this systematic review pointed out the mean value of 37.13 ± 0.24 °C measured by ingestible capsules as reference for resting Tgastrointestinal in healthy adult individuals.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Engineering and Technology
Journal of Medical Engineering and Technology Engineering-Biomedical Engineering
CiteScore
4.60
自引率
0.00%
发文量
77
期刊介绍: The Journal of Medical Engineering & Technology is an international, independent, multidisciplinary, bimonthly journal promoting an understanding of the physiological processes underlying disease processes and the appropriate application of technology. Features include authoritative review papers, the reporting of original research, and evaluation reports on new and existing techniques and devices. Each issue of the journal contains a comprehensive information service which provides news relevant to the world of medical technology, details of new products, book reviews, and selected contents of related journals.
期刊最新文献
News and product update. Safety, feasibility, and acceptability of a novel device to monitor ischaemic stroke patients. An enhanced Garter Snake Optimization-assisted deep learning model for lung cancer segmentation and classification using CT images. Transformative applications of additive manufacturing in biomedical engineering: bioprinting to surgical innovations. Characterisation of pulmonary air leak measurements using a mechanical ventilator in a bench setup.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1