正常腓骨结节的超声测量:正常解剖测量的验证以及观察者内部和观察者之间可靠性的评估。

Polish journal of radiology Pub Date : 2024-04-10 eCollection Date: 2024-01-01 DOI:10.5114/pjr.2024.138791
Frederik Bosmans, Tine Logghe, Filip Vanhoenacker
{"title":"正常腓骨结节的超声测量:正常解剖测量的验证以及观察者内部和观察者之间可靠性的评估。","authors":"Frederik Bosmans, Tine Logghe, Filip Vanhoenacker","doi":"10.5114/pjr.2024.138791","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to investigate if ultrasound could be a reliable and accurate tool to measure the size of the peroneal tubercle.</p><p><strong>Material and methods: </strong>This study measured the width, length, and height of the peroneal tubercle in 100 asymptomatic patients, comparing the measurements to prior radiographs of the foot (if available) and previously reported anatomical data. This study also assessed the intra- and interrater reliability of ultrasound as a measurement tool.</p><p><strong>Results: </strong>Our findings show that ultrasound measurements of the peroneal tubercle were consistent with values reported in the literature and prior radiographs concerning width. Both intra- and inter-observer measurements were reliable.</p><p><strong>Conclusions: </strong>This study highlights the potential of ultrasound imaging as a promising tool to measure the peroneal tubercle, and it could contribute to a better understanding of peroneal tendon disorders.</p>","PeriodicalId":94174,"journal":{"name":"Polish journal of radiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11112414/pdf/","citationCount":"0","resultStr":"{\"title\":\"Ultrasound measurements of the normal peroneal tubercle: validation of the normal anatomical measurements and evaluation of the intra- and interobserver reliability.\",\"authors\":\"Frederik Bosmans, Tine Logghe, Filip Vanhoenacker\",\"doi\":\"10.5114/pjr.2024.138791\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to investigate if ultrasound could be a reliable and accurate tool to measure the size of the peroneal tubercle.</p><p><strong>Material and methods: </strong>This study measured the width, length, and height of the peroneal tubercle in 100 asymptomatic patients, comparing the measurements to prior radiographs of the foot (if available) and previously reported anatomical data. This study also assessed the intra- and interrater reliability of ultrasound as a measurement tool.</p><p><strong>Results: </strong>Our findings show that ultrasound measurements of the peroneal tubercle were consistent with values reported in the literature and prior radiographs concerning width. Both intra- and inter-observer measurements were reliable.</p><p><strong>Conclusions: </strong>This study highlights the potential of ultrasound imaging as a promising tool to measure the peroneal tubercle, and it could contribute to a better understanding of peroneal tendon disorders.</p>\",\"PeriodicalId\":94174,\"journal\":{\"name\":\"Polish journal of radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11112414/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish journal of radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/pjr.2024.138791\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish journal of radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/pjr.2024.138791","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在探讨超声波是否是测量腓骨结节大小的可靠而准确的工具:本研究测量了 100 名无症状患者的腓骨结节宽度、长度和高度,并将测量结果与之前的足部 X 光片(如有)和之前报道的解剖数据进行了比较。这项研究还评估了超声波作为测量工具的内部和相互之间的可靠性:结果:我们的研究结果表明,超声波对腓骨结节的测量结果与文献报道的数值以及之前的X光片上有关宽度的测量结果一致。观察者内部和观察者之间的测量结果都是可靠的:本研究强调了超声成像作为一种测量腓骨结节的有前途的工具的潜力,它有助于更好地了解腓骨肌腱疾病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasound measurements of the normal peroneal tubercle: validation of the normal anatomical measurements and evaluation of the intra- and interobserver reliability.

Purpose: The aim of this study was to investigate if ultrasound could be a reliable and accurate tool to measure the size of the peroneal tubercle.

Material and methods: This study measured the width, length, and height of the peroneal tubercle in 100 asymptomatic patients, comparing the measurements to prior radiographs of the foot (if available) and previously reported anatomical data. This study also assessed the intra- and interrater reliability of ultrasound as a measurement tool.

Results: Our findings show that ultrasound measurements of the peroneal tubercle were consistent with values reported in the literature and prior radiographs concerning width. Both intra- and inter-observer measurements were reliable.

Conclusions: This study highlights the potential of ultrasound imaging as a promising tool to measure the peroneal tubercle, and it could contribute to a better understanding of peroneal tendon disorders.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
期刊最新文献
Advancing radiology education for medical students: leveraging digital tools and resources. Application of ultrasound-guided intranodal lymphangiography in the diagnosis and treatment of chylous ascites after abdominal surgery. Medication-induced changes on magnetic resonance imaging of the brain. The peritumoral brain zone in glioblastoma: a review of the pretreatment approach. Comparative efficacy of contrast-enhanced ultrasound versus B-mode ultrasound in the diagnosis and monitoring of hepatic abscesses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1