重症患者超声引导下的腋动脉导管置入及相关并发症。

IF 3 3区 医学 Q2 CRITICAL CARE MEDICINE Journal of Intensive Care Medicine Pub Date : 2024-09-01 Epub Date: 2024-05-25 DOI:10.1177/08850666241257417
Stephanie Cardona, Aliza S Gross, Allen T Yu, Adel Bassily-Marcus, John Oropello, Anthony Manasia
{"title":"重症患者超声引导下的腋动脉导管置入及相关并发症。","authors":"Stephanie Cardona, Aliza S Gross, Allen T Yu, Adel Bassily-Marcus, John Oropello, Anthony Manasia","doi":"10.1177/08850666241257417","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Arterial catheter placement for hemodynamic monitoring is commonly performed in critically ill patients. The radial and femoral arteries are the two sites most frequently used; there is limited data on the use of the axillary artery for this purpose. The aim of this study was to investigate the rate of complications from ultrasound-guided axillary artery catheter placement in critically ill patients.</p><p><strong>Methods: </strong>A retrospective study at a tertiary care center of patients admitted to an intensive care unit who had ultrasound-guided axillary artery catheter placement during admission. Primary outcome of interest was catheter related complications, including bleeding, vascular complications, compartment syndrome, stroke or air embolism, catheter malfunction, and need for surgical intervention.</p><p><strong>Results: </strong>This study identified 88 patients who had an ultrasound-guided axillary artery catheter placed during their admission. Of these 88, nine patients required multiple catheters placed, for a total of 99 axillary artery catheter placement events. The median age was 64 [IQR 48, 71], 41 (47%) were female, and median body mass index (BMI) was 26 [IQR 22, 30]. The most common complication was minor bleeding (11%), followed by catheter malfunction (2%), and vascular complications (2%). Univariate analyses did not show any association between demographics and clinical variables, and complications related to axillary arterial catheter.</p><p><strong>Conclusion: </strong>The most common complication found with ultrasound-guided axillary artery catheter placement was minor bleeding, followed by catheter malfunction, and vascular complications. Ultrasound-guided axillary arterial catheters are an alternative in patients in whom radial or femoral arterial access is difficult or not possible to achieve.</p>","PeriodicalId":16307,"journal":{"name":"Journal of Intensive Care Medicine","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasound-guided Axillary Artery Catheter Placement and Associated Complications in Critically Ill Patients.\",\"authors\":\"Stephanie Cardona, Aliza S Gross, Allen T Yu, Adel Bassily-Marcus, John Oropello, Anthony Manasia\",\"doi\":\"10.1177/08850666241257417\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Arterial catheter placement for hemodynamic monitoring is commonly performed in critically ill patients. The radial and femoral arteries are the two sites most frequently used; there is limited data on the use of the axillary artery for this purpose. The aim of this study was to investigate the rate of complications from ultrasound-guided axillary artery catheter placement in critically ill patients.</p><p><strong>Methods: </strong>A retrospective study at a tertiary care center of patients admitted to an intensive care unit who had ultrasound-guided axillary artery catheter placement during admission. Primary outcome of interest was catheter related complications, including bleeding, vascular complications, compartment syndrome, stroke or air embolism, catheter malfunction, and need for surgical intervention.</p><p><strong>Results: </strong>This study identified 88 patients who had an ultrasound-guided axillary artery catheter placed during their admission. Of these 88, nine patients required multiple catheters placed, for a total of 99 axillary artery catheter placement events. The median age was 64 [IQR 48, 71], 41 (47%) were female, and median body mass index (BMI) was 26 [IQR 22, 30]. The most common complication was minor bleeding (11%), followed by catheter malfunction (2%), and vascular complications (2%). Univariate analyses did not show any association between demographics and clinical variables, and complications related to axillary arterial catheter.</p><p><strong>Conclusion: </strong>The most common complication found with ultrasound-guided axillary artery catheter placement was minor bleeding, followed by catheter malfunction, and vascular complications. Ultrasound-guided axillary arterial catheters are an alternative in patients in whom radial or femoral arterial access is difficult or not possible to achieve.</p>\",\"PeriodicalId\":16307,\"journal\":{\"name\":\"Journal of Intensive Care Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Intensive Care Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/08850666241257417\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Intensive Care Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08850666241257417","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景:动脉导管置入用于血流动力学监测是重症患者的常见操作。桡动脉和股动脉是最常使用的两个部位;关于腋动脉的使用数据有限。本研究旨在调查重症患者在超声引导下置入腋动脉导管的并发症发生率:在一家三级医疗中心进行的一项回顾性研究,研究对象是重症监护病房的入院患者,他们在入院时在超声引导下置入了腋动脉导管。研究的主要结果是导管相关并发症,包括出血、血管并发症、隔室综合征、中风或空气栓塞、导管故障以及手术干预需求:这项研究确定了88名在入院时放置了超声引导腋动脉导管的患者。在这88名患者中,有9名患者需要置入多根导管,共计99例腋窝动脉导管置入事件。中位年龄为 64 [IQR 48,71],41(47%)人为女性,中位体重指数(BMI)为 26 [IQR 22,30]。最常见的并发症是轻微出血(11%),其次是导管故障(2%)和血管并发症(2%)。单变量分析未显示人口统计学和临床变量与腋动脉导管相关并发症之间存在任何关联:结论:超声引导下置入腋动脉导管最常见的并发症是轻微出血,其次是导管故障和血管并发症。对于难以或无法进行桡动脉或股动脉入路的患者,超声引导下的腋动脉导管是一种替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasound-guided Axillary Artery Catheter Placement and Associated Complications in Critically Ill Patients.

Background: Arterial catheter placement for hemodynamic monitoring is commonly performed in critically ill patients. The radial and femoral arteries are the two sites most frequently used; there is limited data on the use of the axillary artery for this purpose. The aim of this study was to investigate the rate of complications from ultrasound-guided axillary artery catheter placement in critically ill patients.

Methods: A retrospective study at a tertiary care center of patients admitted to an intensive care unit who had ultrasound-guided axillary artery catheter placement during admission. Primary outcome of interest was catheter related complications, including bleeding, vascular complications, compartment syndrome, stroke or air embolism, catheter malfunction, and need for surgical intervention.

Results: This study identified 88 patients who had an ultrasound-guided axillary artery catheter placed during their admission. Of these 88, nine patients required multiple catheters placed, for a total of 99 axillary artery catheter placement events. The median age was 64 [IQR 48, 71], 41 (47%) were female, and median body mass index (BMI) was 26 [IQR 22, 30]. The most common complication was minor bleeding (11%), followed by catheter malfunction (2%), and vascular complications (2%). Univariate analyses did not show any association between demographics and clinical variables, and complications related to axillary arterial catheter.

Conclusion: The most common complication found with ultrasound-guided axillary artery catheter placement was minor bleeding, followed by catheter malfunction, and vascular complications. Ultrasound-guided axillary arterial catheters are an alternative in patients in whom radial or femoral arterial access is difficult or not possible to achieve.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Intensive Care Medicine
Journal of Intensive Care Medicine CRITICAL CARE MEDICINE-
CiteScore
7.60
自引率
3.20%
发文量
107
期刊介绍: Journal of Intensive Care Medicine (JIC) is a peer-reviewed bi-monthly journal offering medical and surgical clinicians in adult and pediatric intensive care state-of-the-art, broad-based analytic reviews and updates, original articles, reports of large clinical series, techniques and procedures, topic-specific electronic resources, book reviews, and editorials on all aspects of intensive/critical/coronary care.
期刊最新文献
Development of an Extended Cardiovascular SOFA Score Component Reflecting Cardiac Dysfunction with Improved Survival Prediction in Sepsis: An Exploratory Analysis in the Sepsis and Elevated Troponin (SET) Study. Myoclonus After Cardiac Arrest did not Correlate with Cortical Response on Somatosensory Evoked Potentials. Predicting Parental Post-Traumatic Stress Symptoms Following their Child's Stay in a Pediatric Intensive Care Unit, Prior to Discharge. Intubation and Mechanical Ventilation in Patients with Acute Pulmonary Embolism: A Scoping Review. Effect of Extended Prone Positioning in Intubated COVID-19 Patients with Acute Respiratory Distress Syndrome, a Revision Letter.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1