对比磁共振成像评估对比增强超声波在宫颈癌中的价值

Q2 Medicine Medicine and Pharmacy Reports Pub Date : 2024-05-24 DOI:10.15386/mpr-2746
R. Ignat, Zsolt Fekete, C. Csutak, Nicolae Todor, Florin Laurentiu Ignat, Patricia Ignat, Radu Badea
{"title":"对比磁共振成像评估对比增强超声波在宫颈癌中的价值","authors":"R. Ignat, Zsolt Fekete, C. Csutak, Nicolae Todor, Florin Laurentiu Ignat, Patricia Ignat, Radu Badea","doi":"10.15386/mpr-2746","DOIUrl":null,"url":null,"abstract":"Introduction. Currently, magnetic resonance imaging (MRI) is the most commonly used imaging method in the assessment of the loco-regional extension in cervical cancer. Contrast-enhanced ultrasound (abbreviated CEUS) is being investigated as an alternative or complement to the MRI investigation. \nObjectives. To evaluate the performance of CEUS in identifying loco-regional invasion of cervical cancer compared to MRI, considered the accepted reference standard. \nMethod. Sixty-one patients with histopathologically confirmed cervical cancer were investigated as part of the pre-treatment workup by CEUS and MRI. We calculated the accuracy and concordance of CEUS versus MRI for tumor invasion in the vagina, bladder, rectum, parametrium, and uterus. For the time-intensity curve associated parameters analyzed (TTPK, AUC, peak intensity, wash in and wash out gradient) we calculated sensitivity, specificity and threshold value of positivity, for tumor invasion at the above-mentioned sites, with graphical representation of the ROC (receiver operating characteristic) curve. \nResults. CEUS was highly accurate in detecting bladder (93.4%, 95% CI: 87.2- 99.6) and uterine invasion (88.5%, 95% CI: 80.5-96.5). Substantial agreement between CEUS and MRI was observed for invasion in the uterine body (k=0.77, 95% CI: 0.56-0.98) and bladder (k=0.56, 95% CI: 0.35-0.77). ROC curve analysis for loco-regional invasions showed that the wash in gradient at a cut-off value of 2.23 had a sensitivity of 76% and a specificity of 67% in predicting uterine invasion. \nConclusions. Our results demonstrate high accuracy and good agreement between CEUS and MRI regarding especially uterine and bladder invasion. This imaging method could help select patients in early stages for fertility sparing surgery, and also be of use in cases in which early bladder invasion is suspected.","PeriodicalId":18438,"journal":{"name":"Medicine and Pharmacy Reports","volume":"10 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The value of contrast-enhanced ultrasound in cervical cancer assessed in comparison with magnetic resonance imaging\",\"authors\":\"R. Ignat, Zsolt Fekete, C. Csutak, Nicolae Todor, Florin Laurentiu Ignat, Patricia Ignat, Radu Badea\",\"doi\":\"10.15386/mpr-2746\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction. Currently, magnetic resonance imaging (MRI) is the most commonly used imaging method in the assessment of the loco-regional extension in cervical cancer. Contrast-enhanced ultrasound (abbreviated CEUS) is being investigated as an alternative or complement to the MRI investigation. \\nObjectives. To evaluate the performance of CEUS in identifying loco-regional invasion of cervical cancer compared to MRI, considered the accepted reference standard. \\nMethod. Sixty-one patients with histopathologically confirmed cervical cancer were investigated as part of the pre-treatment workup by CEUS and MRI. We calculated the accuracy and concordance of CEUS versus MRI for tumor invasion in the vagina, bladder, rectum, parametrium, and uterus. For the time-intensity curve associated parameters analyzed (TTPK, AUC, peak intensity, wash in and wash out gradient) we calculated sensitivity, specificity and threshold value of positivity, for tumor invasion at the above-mentioned sites, with graphical representation of the ROC (receiver operating characteristic) curve. \\nResults. CEUS was highly accurate in detecting bladder (93.4%, 95% CI: 87.2- 99.6) and uterine invasion (88.5%, 95% CI: 80.5-96.5). Substantial agreement between CEUS and MRI was observed for invasion in the uterine body (k=0.77, 95% CI: 0.56-0.98) and bladder (k=0.56, 95% CI: 0.35-0.77). ROC curve analysis for loco-regional invasions showed that the wash in gradient at a cut-off value of 2.23 had a sensitivity of 76% and a specificity of 67% in predicting uterine invasion. \\nConclusions. Our results demonstrate high accuracy and good agreement between CEUS and MRI regarding especially uterine and bladder invasion. This imaging method could help select patients in early stages for fertility sparing surgery, and also be of use in cases in which early bladder invasion is suspected.\",\"PeriodicalId\":18438,\"journal\":{\"name\":\"Medicine and Pharmacy Reports\",\"volume\":\"10 9\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicine and Pharmacy Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15386/mpr-2746\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine and Pharmacy Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15386/mpr-2746","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

简介目前,磁共振成像(MRI)是评估宫颈癌局部区域扩展最常用的成像方法。目前正在研究对比增强超声波(简称 CEUS),作为核磁共振成像检查的替代或补充方法。研究目的与公认的参考标准 MRI 相比,评估 CEUS 在确定宫颈癌局部区域侵犯方面的性能。方法。作为治疗前检查的一部分,我们对 61 名经组织病理学确诊的宫颈癌患者进行了 CEUS 和 MRI 检查。我们计算了 CEUS 和 MRI 对阴道、膀胱、直肠、宫旁和子宫肿瘤侵犯的准确性和一致性。对于所分析的时间-强度曲线相关参数(TTPK、AUC、峰值强度、洗入和洗出梯度),我们计算了上述部位肿瘤侵犯的敏感性、特异性和阳性阈值,并绘制了 ROC(接收者操作特征)曲线。结果显示CEUS 对膀胱(93.4%,95% CI:87.2-99.6)和子宫(88.5%,95% CI:80.5-96.5)肿瘤侵犯的检测非常准确。在子宫体(k=0.77,95% CI:0.56-0.98)和膀胱(k=0.56,95% CI:0.35-0.77)浸润方面,CEUS 和 MRI 的结果基本一致。局部区域侵犯的 ROC 曲线分析表明,截断值为 2.23 的洗脱梯度在预测子宫侵犯方面的灵敏度为 76%,特异度为 67%。结论。我们的研究结果表明,CEUS 和磁共振成像在子宫和膀胱受侵方面的准确性和一致性很高。这种成像方法有助于选择早期患者进行保留生育功能的手术,也可用于怀疑早期膀胱侵犯的病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The value of contrast-enhanced ultrasound in cervical cancer assessed in comparison with magnetic resonance imaging
Introduction. Currently, magnetic resonance imaging (MRI) is the most commonly used imaging method in the assessment of the loco-regional extension in cervical cancer. Contrast-enhanced ultrasound (abbreviated CEUS) is being investigated as an alternative or complement to the MRI investigation. Objectives. To evaluate the performance of CEUS in identifying loco-regional invasion of cervical cancer compared to MRI, considered the accepted reference standard. Method. Sixty-one patients with histopathologically confirmed cervical cancer were investigated as part of the pre-treatment workup by CEUS and MRI. We calculated the accuracy and concordance of CEUS versus MRI for tumor invasion in the vagina, bladder, rectum, parametrium, and uterus. For the time-intensity curve associated parameters analyzed (TTPK, AUC, peak intensity, wash in and wash out gradient) we calculated sensitivity, specificity and threshold value of positivity, for tumor invasion at the above-mentioned sites, with graphical representation of the ROC (receiver operating characteristic) curve. Results. CEUS was highly accurate in detecting bladder (93.4%, 95% CI: 87.2- 99.6) and uterine invasion (88.5%, 95% CI: 80.5-96.5). Substantial agreement between CEUS and MRI was observed for invasion in the uterine body (k=0.77, 95% CI: 0.56-0.98) and bladder (k=0.56, 95% CI: 0.35-0.77). ROC curve analysis for loco-regional invasions showed that the wash in gradient at a cut-off value of 2.23 had a sensitivity of 76% and a specificity of 67% in predicting uterine invasion. Conclusions. Our results demonstrate high accuracy and good agreement between CEUS and MRI regarding especially uterine and bladder invasion. This imaging method could help select patients in early stages for fertility sparing surgery, and also be of use in cases in which early bladder invasion is suspected.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medicine and Pharmacy Reports
Medicine and Pharmacy Reports Medicine-Medicine (all)
CiteScore
3.10
自引率
0.00%
发文量
63
期刊最新文献
5-Azacytidine treatment inhibits the development of lung cancer models via epigenetic reprogramming and activation of cellular pathways with anti-tumor activity. Artificial Intelligence and medical specialties: support or substitution? Clonal distribution and molecular characterization of Staphylococcus aureus isolated strains in Chania and Heraklion, Crete. Exploring anesthesia-related complications in pediatric neurosurgery: a comparative analysis of the sitting and park-bench positions. Genetic and clinical factors influencing CF-associated liver disease: the impact of SERPINA1 variants and CFTR genotypes in Romanian pediatric cystic fibrosis patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1