Zachary M. Connelly, Matthew Moss, Tomas Paneque, Coleman McFerrin, Kevin Morgan, Mohamed Ahmed, Nazih Khater
{"title":"受训者在外科医生操作台上的手指位置是否会影响机器人手术(尤其是根治性前列腺切除术)的整体效果?","authors":"Zachary M. Connelly, Matthew Moss, Tomas Paneque, Coleman McFerrin, Kevin Morgan, Mohamed Ahmed, Nazih Khater","doi":"10.5489/cuaj.8709","DOIUrl":null,"url":null,"abstract":"Introduction: Robotic surgery for localized prostate cancer offers a greater range of motion attributed to the EndoWrist instruments. Postoperative outcomes are linked to the quality of vesico-urethral anastomosis. Trainees frequently complain of suturing difficulty in a back-handed fashion. We aimed to analyze wrist motion using the DaVinci simulator. We hypothesized that using the thumb and index finger would allow superior surgical proficiency when compared to the middle finger.\nMethods: After institutional review board approval, we recruited 42 medical students in one academic medical center. Students were randomly assigned to start with their thumb and index finger (1&2) or thumb and middle finger (1&3). Three standardized modules were used with nine metrics calculated, including: score, total time, economy of motion, efficiency score, collisions, inaccurate puncture, wound approximation, out of view, and penalty subtotal. Statistical analysis of the metrics was calculated using SPSS.\nResults: Three metrics were found to have differences between the finger placement of 1&3 compared to 1&2. The number of collisions, wound approximation, and penalty score where 1&3 were used had a lower score in each. The number of collisions was 5.7 less in the 1&3 finger placement (p=0.046). This metric was found to have statistically significant differences between finger placement where 1&3 had a lower score compared to 1&2. The wound approximation score was 0.2 points lower when using the 1&3 placement (p=0.075). Lastly, the penalty assigned was 6.5 points lower when using 1&3 (p=0.069).\nConclusions: Although finger placement did not affect the overall score of the completed simulation, instrument collisions and unnecessary wound complications may lead to adverse outcomes when using 1&2 despite offering a wider range of motion. This may be due to decreased comfort in hand position. Trainees may be able to improve the effectiveness of their vesico-urethral anastomosis during robotic-assisted radical prostatectomy.","PeriodicalId":38001,"journal":{"name":"Canadian Urological Association Journal","volume":"50 17","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Could trainees’ finger placement at the surgeon’s console have any effect on the overall outcomes of robotic surgery specifically in radical prostatectomy?\",\"authors\":\"Zachary M. Connelly, Matthew Moss, Tomas Paneque, Coleman McFerrin, Kevin Morgan, Mohamed Ahmed, Nazih Khater\",\"doi\":\"10.5489/cuaj.8709\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Robotic surgery for localized prostate cancer offers a greater range of motion attributed to the EndoWrist instruments. Postoperative outcomes are linked to the quality of vesico-urethral anastomosis. Trainees frequently complain of suturing difficulty in a back-handed fashion. We aimed to analyze wrist motion using the DaVinci simulator. We hypothesized that using the thumb and index finger would allow superior surgical proficiency when compared to the middle finger.\\nMethods: After institutional review board approval, we recruited 42 medical students in one academic medical center. Students were randomly assigned to start with their thumb and index finger (1&2) or thumb and middle finger (1&3). Three standardized modules were used with nine metrics calculated, including: score, total time, economy of motion, efficiency score, collisions, inaccurate puncture, wound approximation, out of view, and penalty subtotal. Statistical analysis of the metrics was calculated using SPSS.\\nResults: Three metrics were found to have differences between the finger placement of 1&3 compared to 1&2. The number of collisions, wound approximation, and penalty score where 1&3 were used had a lower score in each. The number of collisions was 5.7 less in the 1&3 finger placement (p=0.046). This metric was found to have statistically significant differences between finger placement where 1&3 had a lower score compared to 1&2. The wound approximation score was 0.2 points lower when using the 1&3 placement (p=0.075). Lastly, the penalty assigned was 6.5 points lower when using 1&3 (p=0.069).\\nConclusions: Although finger placement did not affect the overall score of the completed simulation, instrument collisions and unnecessary wound complications may lead to adverse outcomes when using 1&2 despite offering a wider range of motion. This may be due to decreased comfort in hand position. Trainees may be able to improve the effectiveness of their vesico-urethral anastomosis during robotic-assisted radical prostatectomy.\",\"PeriodicalId\":38001,\"journal\":{\"name\":\"Canadian Urological Association Journal\",\"volume\":\"50 17\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Urological Association Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5489/cuaj.8709\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Urological Association Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5489/cuaj.8709","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Could trainees’ finger placement at the surgeon’s console have any effect on the overall outcomes of robotic surgery specifically in radical prostatectomy?
Introduction: Robotic surgery for localized prostate cancer offers a greater range of motion attributed to the EndoWrist instruments. Postoperative outcomes are linked to the quality of vesico-urethral anastomosis. Trainees frequently complain of suturing difficulty in a back-handed fashion. We aimed to analyze wrist motion using the DaVinci simulator. We hypothesized that using the thumb and index finger would allow superior surgical proficiency when compared to the middle finger.
Methods: After institutional review board approval, we recruited 42 medical students in one academic medical center. Students were randomly assigned to start with their thumb and index finger (1&2) or thumb and middle finger (1&3). Three standardized modules were used with nine metrics calculated, including: score, total time, economy of motion, efficiency score, collisions, inaccurate puncture, wound approximation, out of view, and penalty subtotal. Statistical analysis of the metrics was calculated using SPSS.
Results: Three metrics were found to have differences between the finger placement of 1&3 compared to 1&2. The number of collisions, wound approximation, and penalty score where 1&3 were used had a lower score in each. The number of collisions was 5.7 less in the 1&3 finger placement (p=0.046). This metric was found to have statistically significant differences between finger placement where 1&3 had a lower score compared to 1&2. The wound approximation score was 0.2 points lower when using the 1&3 placement (p=0.075). Lastly, the penalty assigned was 6.5 points lower when using 1&3 (p=0.069).
Conclusions: Although finger placement did not affect the overall score of the completed simulation, instrument collisions and unnecessary wound complications may lead to adverse outcomes when using 1&2 despite offering a wider range of motion. This may be due to decreased comfort in hand position. Trainees may be able to improve the effectiveness of their vesico-urethral anastomosis during robotic-assisted radical prostatectomy.
期刊介绍:
Published by the Canadian Urological Association, the Canadian Urological Association Journal (CUAJ) released its first issue in March 2007, and was published four times that year under the guidance of founding editor (Editor Emeritus as of 2012), Dr. Laurence H. Klotz. In 2008, CUAJ became a bimonthly publication. As of 2013, articles have been published monthly, alternating between print and online-only versions (print issues are available in February, April, June, August, October, and December; online-only issues are produced in January, March, May, July, September, and November). In 2017, the journal launched an ahead-of-print publishing strategy, in which accepted manuscripts are published electronically on our website and cited on PubMed ahead of their official issue-based publication date. By significantly shortening the time to article availability, we offer our readers more flexibility in the way they engage with our content: as a continuous stream, or in a monthly “package,” or both. CUAJ covers a broad range of urological topics — oncology, pediatrics, transplantation, endourology, female urology, infertility, and more. We take pride in showcasing the work of some of Canada’s top investigators and providing our readers with the latest relevant evidence-based research, and on being the primary repository for major guidelines and other important practice recommendations. Our long-term vision is to become an essential destination for urology-based research, education, and advocacy for both physicians and patients, and to act as a springboard for discussions within the urologic community.