通过光学相干断层扫描全自动构建三维有限元模拟

Ross Straughan, Karim Kadry, Sahil A. Parikh, Elazer R. Edelman, Farhad R. Nezami
{"title":"通过光学相干断层扫描全自动构建三维有限元模拟","authors":"Ross Straughan, Karim Kadry, Sahil A. Parikh, Elazer R. Edelman, Farhad R. Nezami","doi":"arxiv-2405.13643","DOIUrl":null,"url":null,"abstract":"Despite recent advances in diagnosis and treatment, atherosclerotic coronary\nartery diseases remain a leading cause of death worldwide. Various imaging\nmodalities and metrics can detect lesions and predict patients at risk;\nhowever, identifying unstable lesions is still difficult. Current techniques\ncannot fully capture the complex morphology-modulated mechanical responses that\naffect plaque stability, leading to catastrophic failure and mute the benefit\nof device and drug interventions. Finite Element (FE) simulations utilizing\nintravascular imaging OCT (Optical Coherence Tomography) are effective in\ndefining physiological stress distributions. However, creating 3D FE\nsimulations of coronary arteries from OCT images is challenging to fully\nautomate given OCT frame sparsity, limited material contrast, and restricted\npenetration depth. To address such limitations, we developed an algorithmic\napproach to automatically produce 3D FE-ready digital twins from labeled OCT\nimages. The 3D models are anatomically faithful and recapitulate mechanically\nrelevant tissue lesion components, automatically producing morphologies\nstructurally similar to manually constructed models whilst including more\nminute details. A mesh convergence study highlighted the ability to reach\nstress and strain convergence with average errors of just 5.9% and 1.6%\nrespectively in comparison to FE models with approximately twice the number of\nelements in areas of refinement. Such an automated procedure will enable\nanalysis of large clinical cohorts at a previously unattainable scale and opens\nthe possibility for in-silico methods for patient specific diagnoses and\ntreatment planning for coronary artery disease.","PeriodicalId":501572,"journal":{"name":"arXiv - QuanBio - Tissues and Organs","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fully automated construction of three-dimensional finite element simulations from Optical Coherence Tomography\",\"authors\":\"Ross Straughan, Karim Kadry, Sahil A. Parikh, Elazer R. Edelman, Farhad R. Nezami\",\"doi\":\"arxiv-2405.13643\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Despite recent advances in diagnosis and treatment, atherosclerotic coronary\\nartery diseases remain a leading cause of death worldwide. Various imaging\\nmodalities and metrics can detect lesions and predict patients at risk;\\nhowever, identifying unstable lesions is still difficult. Current techniques\\ncannot fully capture the complex morphology-modulated mechanical responses that\\naffect plaque stability, leading to catastrophic failure and mute the benefit\\nof device and drug interventions. Finite Element (FE) simulations utilizing\\nintravascular imaging OCT (Optical Coherence Tomography) are effective in\\ndefining physiological stress distributions. However, creating 3D FE\\nsimulations of coronary arteries from OCT images is challenging to fully\\nautomate given OCT frame sparsity, limited material contrast, and restricted\\npenetration depth. To address such limitations, we developed an algorithmic\\napproach to automatically produce 3D FE-ready digital twins from labeled OCT\\nimages. The 3D models are anatomically faithful and recapitulate mechanically\\nrelevant tissue lesion components, automatically producing morphologies\\nstructurally similar to manually constructed models whilst including more\\nminute details. A mesh convergence study highlighted the ability to reach\\nstress and strain convergence with average errors of just 5.9% and 1.6%\\nrespectively in comparison to FE models with approximately twice the number of\\nelements in areas of refinement. Such an automated procedure will enable\\nanalysis of large clinical cohorts at a previously unattainable scale and opens\\nthe possibility for in-silico methods for patient specific diagnoses and\\ntreatment planning for coronary artery disease.\",\"PeriodicalId\":501572,\"journal\":{\"name\":\"arXiv - QuanBio - Tissues and Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv - QuanBio - Tissues and Organs\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/arxiv-2405.13643\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv - QuanBio - Tissues and Organs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/arxiv-2405.13643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

尽管最近在诊断和治疗方面取得了进展,但动脉粥样硬化性冠状动脉疾病仍然是全球死亡的主要原因。各种成像模式和指标可以检测病变并预测高危患者;然而,识别不稳定病变仍然困难重重。目前的技术无法完全捕捉到影响斑块稳定性的复杂形态调节机械反应,从而导致灾难性的失败,并削弱了设备和药物干预的益处。利用血管内成像 OCT(光学相干断层扫描)进行有限元(FE)模拟能有效确定生理应力分布。然而,由于 OCT 图框稀疏、材料对比度有限以及穿透深度受限,要从 OCT 图像创建冠状动脉的三维有限元模拟,完全自动化具有挑战性。为了解决这些限制,我们开发了一种算法方法,从标记的 OCT 图像中自动生成三维 FE 就绪数字双胞胎。这些三维模型在解剖学上忠实再现了与机械相关的组织病变成分,自动生成的形态结构与人工构建的模型相似,同时包含更多的细节。网格收敛研究表明,与细化区域元素数量约为两倍的 FE 模型相比,该模型能够实现应力和应变收敛,平均误差分别仅为 5.9% 和 1.6%。这种自动化程序将能够以以前无法实现的规模对大型临床队列进行分析,并为冠状动脉疾病的患者特异性诊断和治疗计划的室内方法提供了可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fully automated construction of three-dimensional finite element simulations from Optical Coherence Tomography
Despite recent advances in diagnosis and treatment, atherosclerotic coronary artery diseases remain a leading cause of death worldwide. Various imaging modalities and metrics can detect lesions and predict patients at risk; however, identifying unstable lesions is still difficult. Current techniques cannot fully capture the complex morphology-modulated mechanical responses that affect plaque stability, leading to catastrophic failure and mute the benefit of device and drug interventions. Finite Element (FE) simulations utilizing intravascular imaging OCT (Optical Coherence Tomography) are effective in defining physiological stress distributions. However, creating 3D FE simulations of coronary arteries from OCT images is challenging to fully automate given OCT frame sparsity, limited material contrast, and restricted penetration depth. To address such limitations, we developed an algorithmic approach to automatically produce 3D FE-ready digital twins from labeled OCT images. The 3D models are anatomically faithful and recapitulate mechanically relevant tissue lesion components, automatically producing morphologies structurally similar to manually constructed models whilst including more minute details. A mesh convergence study highlighted the ability to reach stress and strain convergence with average errors of just 5.9% and 1.6% respectively in comparison to FE models with approximately twice the number of elements in areas of refinement. Such an automated procedure will enable analysis of large clinical cohorts at a previously unattainable scale and opens the possibility for in-silico methods for patient specific diagnoses and treatment planning for coronary artery disease.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical Validation of a Real-Time Machine Learning-based System for the Detection of Acute Myeloid Leukemia by Flow Cytometry Dynamic landscapes and statistical limits on growth during cell fate specification (Un)buckling mechanics of epithelial monolayers under compression On the design and stability of cancer adaptive therapy cycles: deterministic and stochastic models Celcomen: spatial causal disentanglement for single-cell and tissue perturbation modeling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1