INJEX50 可提高儿科重症监护室动脉插管局部麻醉的成功率:一项随机、双盲、单中心研究。

IF 1.7 4区 医学 Q2 ANESTHESIOLOGY Pediatric Anesthesia Pub Date : 2024-05-26 DOI:10.1111/pan.14940
Wataru Sakai, Tomohiro Chaki, Shunsuke Tachibana, Yuki Ichisaka, Yuko Nawa, Tomohiro Nawa, Michiaki Yamakage
{"title":"INJEX50 可提高儿科重症监护室动脉插管局部麻醉的成功率:一项随机、双盲、单中心研究。","authors":"Wataru Sakai, Tomohiro Chaki, Shunsuke Tachibana, Yuki Ichisaka, Yuko Nawa, Tomohiro Nawa, Michiaki Yamakage","doi":"10.1111/pan.14940","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Quick arterial cannulation is required in pediatric emergency situation, which require effective local anesthesia to avoid withdrawal movement. However, pediatric local anesthesia could be difficult because of withdrawal movement. Jet injectors, which are needleless and provide local anesthesia quickly, could be helpful for pediatric local anesthesia during arterial cannulation.</p><p><strong>Aims: </strong>This study aimed to examine whether new jet injector \"INJEX50\" could improve the success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with the current standard of care, infiltration using a 26-gauge needle.</p><p><strong>Methods: </strong>This study was a randomized, double-blind, single-center study. Participants were infants and young children in the pediatric intensive care unit, who required an arterial line. Local anesthesia was performed with either a 26-gauge needle (group C) or INJEX50 (group I) before arterial cannulation. The primary outcome (success of local anesthesia) was the presence of withdrawal movement at the time of skin puncture for arterial cannulation. The secondary outcomes included rescue sedation during arterial cannulation. Data were analyzed using Fisher's exact test and the Mann-Whitney U-test, with values of p < .05 considered statistically significant.</p><p><strong>Results: </strong>Seventy patients were randomly assigned to groups C and I. The local anesthesia success rate in group I (30/35 [86%]) was significantly higher than that in group C (15/35 [43%], odds ratio, 8.00; 95% confidence interval, 2.51-25.5; p = .0005). In conclusion, INJEX50 could improve success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with 26-gauge needle.</p>","PeriodicalId":19745,"journal":{"name":"Pediatric Anesthesia","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"INJEX50 could improve the success rate of local anesthesia for arterial cannulation in the pediatric intensive care unit: A randomized, double-blind, single-center study.\",\"authors\":\"Wataru Sakai, Tomohiro Chaki, Shunsuke Tachibana, Yuki Ichisaka, Yuko Nawa, Tomohiro Nawa, Michiaki Yamakage\",\"doi\":\"10.1111/pan.14940\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Quick arterial cannulation is required in pediatric emergency situation, which require effective local anesthesia to avoid withdrawal movement. However, pediatric local anesthesia could be difficult because of withdrawal movement. Jet injectors, which are needleless and provide local anesthesia quickly, could be helpful for pediatric local anesthesia during arterial cannulation.</p><p><strong>Aims: </strong>This study aimed to examine whether new jet injector \\\"INJEX50\\\" could improve the success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with the current standard of care, infiltration using a 26-gauge needle.</p><p><strong>Methods: </strong>This study was a randomized, double-blind, single-center study. Participants were infants and young children in the pediatric intensive care unit, who required an arterial line. Local anesthesia was performed with either a 26-gauge needle (group C) or INJEX50 (group I) before arterial cannulation. The primary outcome (success of local anesthesia) was the presence of withdrawal movement at the time of skin puncture for arterial cannulation. The secondary outcomes included rescue sedation during arterial cannulation. Data were analyzed using Fisher's exact test and the Mann-Whitney U-test, with values of p < .05 considered statistically significant.</p><p><strong>Results: </strong>Seventy patients were randomly assigned to groups C and I. The local anesthesia success rate in group I (30/35 [86%]) was significantly higher than that in group C (15/35 [43%], odds ratio, 8.00; 95% confidence interval, 2.51-25.5; p = .0005). In conclusion, INJEX50 could improve success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with 26-gauge needle.</p>\",\"PeriodicalId\":19745,\"journal\":{\"name\":\"Pediatric Anesthesia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric Anesthesia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/pan.14940\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/pan.14940","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:在儿科急诊情况下需要快速进行动脉插管,这就要求进行有效的局部麻醉以避免抽搐。然而,小儿局部麻醉可能会因抽动而变得困难。目的:本研究旨在探讨新型喷射注射器 "INJEX50 "与目前的标准护理方法(使用 26 号针头浸润)相比,能否提高儿科重症监护病房动脉插管局部麻醉的成功率:本研究是一项随机、双盲、单中心研究。研究对象为儿科重症监护室中需要动脉置管的婴幼儿。在动脉插管前使用 26 号针(C 组)或 INJEX50(I 组)进行局部麻醉。主要结果(局部麻醉成功与否)是在穿刺皮肤进行动脉插管时是否出现抽动。次要结果包括动脉插管时的抢救镇静。数据分析采用费雪精确检验和曼-惠特尼 U 检验,P 值为 结果:I 组的局麻成功率(30/35 [86%])明显高于 C 组(15/35 [43%],几率比,8.00;95% 置信区间,2.51-25.5;P = .0005)。总之,与 26 号针头相比,INJEX50 可提高儿科重症监护病房动脉插管局部麻醉的成功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
INJEX50 could improve the success rate of local anesthesia for arterial cannulation in the pediatric intensive care unit: A randomized, double-blind, single-center study.

Background: Quick arterial cannulation is required in pediatric emergency situation, which require effective local anesthesia to avoid withdrawal movement. However, pediatric local anesthesia could be difficult because of withdrawal movement. Jet injectors, which are needleless and provide local anesthesia quickly, could be helpful for pediatric local anesthesia during arterial cannulation.

Aims: This study aimed to examine whether new jet injector "INJEX50" could improve the success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with the current standard of care, infiltration using a 26-gauge needle.

Methods: This study was a randomized, double-blind, single-center study. Participants were infants and young children in the pediatric intensive care unit, who required an arterial line. Local anesthesia was performed with either a 26-gauge needle (group C) or INJEX50 (group I) before arterial cannulation. The primary outcome (success of local anesthesia) was the presence of withdrawal movement at the time of skin puncture for arterial cannulation. The secondary outcomes included rescue sedation during arterial cannulation. Data were analyzed using Fisher's exact test and the Mann-Whitney U-test, with values of p < .05 considered statistically significant.

Results: Seventy patients were randomly assigned to groups C and I. The local anesthesia success rate in group I (30/35 [86%]) was significantly higher than that in group C (15/35 [43%], odds ratio, 8.00; 95% confidence interval, 2.51-25.5; p = .0005). In conclusion, INJEX50 could improve success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with 26-gauge needle.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pediatric Anesthesia
Pediatric Anesthesia 医学-麻醉学
CiteScore
3.20
自引率
11.80%
发文量
222
审稿时长
3-8 weeks
期刊介绍: Devoted to the dissemination of research of interest and importance to practising anesthetists everywhere, the scientific and clinical content of Pediatric Anesthesia covers a wide selection of medical disciplines in all areas relevant to paediatric anaesthesia, pain management and peri-operative medicine. The International Editorial Board is supported by the Editorial Advisory Board and a team of Senior Advisors, to ensure that the journal is publishing the best work from the front line of research in the field. The journal publishes high-quality, relevant scientific and clinical research papers, reviews, commentaries, pro-con debates, historical vignettes, correspondence, case presentations and book reviews.
期刊最新文献
The power of POCUS in every pocket: Handheld ultrasound the new essential tool? Severe knotting guidewire after central venous catheterization. Ball valve gas trapping in pediatric one-lung ventilation: Not all ventilation is loss of isolation. Links between mutations in functionally separate arms of mitochondrial complex I and responses to volatile anesthetics. Feasibility of bispectral index monitoring during pediatric critical care transport.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1