Patrick B Kyle, Christopher J Mattiello, Albert Hua, Joanne M Toohey, Warren R Korn, Alana Saldana-Reed, Douglas F Stickle
{"title":"评估 ARK Diagnostics 免疫测定法对尿液中甲苯噻嗪的定性检测。","authors":"Patrick B Kyle, Christopher J Mattiello, Albert Hua, Joanne M Toohey, Warren R Korn, Alana Saldana-Reed, Douglas F Stickle","doi":"10.1093/jat/bkae043","DOIUrl":null,"url":null,"abstract":"<p><p>Xylazine exposure is common in some US cities, but a commercial assay for routine laboratory testing for xylazine is not currently available. We evaluated a pre-release version of the ARK Diagnostics immunoassay for qualitative detection of xylazine/4-hydroxyxylazine in urine. Studies were conducted using either the semi-quantitative assay application (A. Roche Cobas 503 analyzer) or the qualitative assay application (B. Beckman Coulter AU480 analyzer). Study specimens consisted of deidentified patient urine samples submitted for routine drugs-of-abuse testing. Measurements of xylazine (X) were performed by LC-MS-MS to obtain X-NEGATIVE (X <10 ng/mL) and X-POSITIVE (X ≥10 ng/mL). The semi-quantitative ARK assay was calibrated with a 10 ng/mL cutoff for ARK-POSITVE. For (A): among 74 X-POSITIVE samples, there was 1 ARK-NEGATIVE result (false-negative rate = 1.4%); among 78 X-NEGATIVE samples by LC-MS-MS, there were 0% ARK-POSITIVE results (false-positive rate = 0%). For (B), among 74 X-POSITIVE samples, there were 0 ARK-NEGATIVE results (false-negative rate = 0%); among 78 X-NEGATIVE samples there was 1 ARK-POSITIVE sample (false-positive rate = 1.3%). Common sources of interferences were investigated without evidence of interference. The ARK xylazine/4-OH-xylazine immunoassay was found to be suitable for routine use in screening patient urine samples for presence of xylazine >10 ng/mL.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":"468-471"},"PeriodicalIF":2.3000,"publicationDate":"2024-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the ARK Diagnostics immunoassay for qualitative detection of xylazine in urine.\",\"authors\":\"Patrick B Kyle, Christopher J Mattiello, Albert Hua, Joanne M Toohey, Warren R Korn, Alana Saldana-Reed, Douglas F Stickle\",\"doi\":\"10.1093/jat/bkae043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Xylazine exposure is common in some US cities, but a commercial assay for routine laboratory testing for xylazine is not currently available. We evaluated a pre-release version of the ARK Diagnostics immunoassay for qualitative detection of xylazine/4-hydroxyxylazine in urine. Studies were conducted using either the semi-quantitative assay application (A. Roche Cobas 503 analyzer) or the qualitative assay application (B. Beckman Coulter AU480 analyzer). Study specimens consisted of deidentified patient urine samples submitted for routine drugs-of-abuse testing. Measurements of xylazine (X) were performed by LC-MS-MS to obtain X-NEGATIVE (X <10 ng/mL) and X-POSITIVE (X ≥10 ng/mL). The semi-quantitative ARK assay was calibrated with a 10 ng/mL cutoff for ARK-POSITVE. For (A): among 74 X-POSITIVE samples, there was 1 ARK-NEGATIVE result (false-negative rate = 1.4%); among 78 X-NEGATIVE samples by LC-MS-MS, there were 0% ARK-POSITIVE results (false-positive rate = 0%). For (B), among 74 X-POSITIVE samples, there were 0 ARK-NEGATIVE results (false-negative rate = 0%); among 78 X-NEGATIVE samples there was 1 ARK-POSITIVE sample (false-positive rate = 1.3%). Common sources of interferences were investigated without evidence of interference. The ARK xylazine/4-OH-xylazine immunoassay was found to be suitable for routine use in screening patient urine samples for presence of xylazine >10 ng/mL.</p>\",\"PeriodicalId\":14905,\"journal\":{\"name\":\"Journal of analytical toxicology\",\"volume\":\" \",\"pages\":\"468-471\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of analytical toxicology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/jat/bkae043\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkae043","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Evaluation of the ARK Diagnostics immunoassay for qualitative detection of xylazine in urine.
Xylazine exposure is common in some US cities, but a commercial assay for routine laboratory testing for xylazine is not currently available. We evaluated a pre-release version of the ARK Diagnostics immunoassay for qualitative detection of xylazine/4-hydroxyxylazine in urine. Studies were conducted using either the semi-quantitative assay application (A. Roche Cobas 503 analyzer) or the qualitative assay application (B. Beckman Coulter AU480 analyzer). Study specimens consisted of deidentified patient urine samples submitted for routine drugs-of-abuse testing. Measurements of xylazine (X) were performed by LC-MS-MS to obtain X-NEGATIVE (X <10 ng/mL) and X-POSITIVE (X ≥10 ng/mL). The semi-quantitative ARK assay was calibrated with a 10 ng/mL cutoff for ARK-POSITVE. For (A): among 74 X-POSITIVE samples, there was 1 ARK-NEGATIVE result (false-negative rate = 1.4%); among 78 X-NEGATIVE samples by LC-MS-MS, there were 0% ARK-POSITIVE results (false-positive rate = 0%). For (B), among 74 X-POSITIVE samples, there were 0 ARK-NEGATIVE results (false-negative rate = 0%); among 78 X-NEGATIVE samples there was 1 ARK-POSITIVE sample (false-positive rate = 1.3%). Common sources of interferences were investigated without evidence of interference. The ARK xylazine/4-OH-xylazine immunoassay was found to be suitable for routine use in screening patient urine samples for presence of xylazine >10 ng/mL.
期刊介绍:
The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation.
Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.