{"title":"对诱导组件位移的无创定量评估可安全准确地诊断患者的胫骨组件松动:前瞻性诊断研究","authors":"George S Buijs, Arthur J Kievit, Maaike A Ter Wee, Caroline Magg, Johannes G G Dobbe, Geert J Streekstra, Matthias U Schafroth, Leendert Blankevoort","doi":"10.1002/ksa.12299","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Aseptic loosening often requires major, expensive and invasive revision surgery. Current diagnostic modalities merely show indirect signs of loosening. A recent proof of concept study proposed a non-invasive technique for the quantitative and visual assessment of implant movement as a diagnostic aid for tibial component loosening. The primary research question addressed is whether this novel diagnostic modality can safely and effectively aid the diagnosis of aseptic loosening.</p><p><strong>Methods: </strong>This clinical study included patients suspected of aseptic total knee arthroplasty (TKA) loosening listed for revision surgery and asymptomatic patients. Safety was evaluated using a numerical rating scale (NRS) for discomfort and by registration of adverse events. Feasibility was assessed by recording the duration and ease of the procedure. Intra- and interrater reliability were evaluated. In symptomatic patients, diagnostic accuracy metrics were evaluated with intra-operative assessment as a reference test.</p><p><strong>Results: </strong>In total, 34 symptomatic and 38 asymptomatic knees with a TKA were analysed. The median NRS for discomfort during loading was 6 (interquartile range [IQR]: 3.75-7.00) in symptomatic patients and 2 (IQR: 1.00-3.00) in asymptomatic patients. No adverse events were reported. The majority of users found the use of the loading device easy. The median time spent in the computed tomography room was 9 min (IQR: 8.00-11.00). Excellent to good intra- and interrater reliabilities were achieved. Diagnostic accuracy analysis resulted in a sensitivity of 0.91 (95% confidence interval [CI]: 0.72-0.97) and a specificity of 0.72 (95% CI: 0.43-0.90).</p><p><strong>Conclusions: </strong>The proposed diagnostic method is safe, feasible, reliable and accurate in aiding the diagnosis of aseptic tibial component loosening.</p><p><strong>Level of evidence: </strong>Level II.</p>","PeriodicalId":17880,"journal":{"name":"Knee Surgery, Sports Traumatology, Arthroscopy","volume":" ","pages":"274-285"},"PeriodicalIF":3.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11716334/pdf/","citationCount":"0","resultStr":"{\"title\":\"Non-invasive quantitative assessment of induced component displacement can safely and accurately diagnose tibial component loosening in patients: A prospective diagnostic study.\",\"authors\":\"George S Buijs, Arthur J Kievit, Maaike A Ter Wee, Caroline Magg, Johannes G G Dobbe, Geert J Streekstra, Matthias U Schafroth, Leendert Blankevoort\",\"doi\":\"10.1002/ksa.12299\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Aseptic loosening often requires major, expensive and invasive revision surgery. Current diagnostic modalities merely show indirect signs of loosening. A recent proof of concept study proposed a non-invasive technique for the quantitative and visual assessment of implant movement as a diagnostic aid for tibial component loosening. The primary research question addressed is whether this novel diagnostic modality can safely and effectively aid the diagnosis of aseptic loosening.</p><p><strong>Methods: </strong>This clinical study included patients suspected of aseptic total knee arthroplasty (TKA) loosening listed for revision surgery and asymptomatic patients. Safety was evaluated using a numerical rating scale (NRS) for discomfort and by registration of adverse events. Feasibility was assessed by recording the duration and ease of the procedure. Intra- and interrater reliability were evaluated. In symptomatic patients, diagnostic accuracy metrics were evaluated with intra-operative assessment as a reference test.</p><p><strong>Results: </strong>In total, 34 symptomatic and 38 asymptomatic knees with a TKA were analysed. The median NRS for discomfort during loading was 6 (interquartile range [IQR]: 3.75-7.00) in symptomatic patients and 2 (IQR: 1.00-3.00) in asymptomatic patients. No adverse events were reported. The majority of users found the use of the loading device easy. The median time spent in the computed tomography room was 9 min (IQR: 8.00-11.00). Excellent to good intra- and interrater reliabilities were achieved. Diagnostic accuracy analysis resulted in a sensitivity of 0.91 (95% confidence interval [CI]: 0.72-0.97) and a specificity of 0.72 (95% CI: 0.43-0.90).</p><p><strong>Conclusions: </strong>The proposed diagnostic method is safe, feasible, reliable and accurate in aiding the diagnosis of aseptic tibial component loosening.</p><p><strong>Level of evidence: </strong>Level II.</p>\",\"PeriodicalId\":17880,\"journal\":{\"name\":\"Knee Surgery, Sports Traumatology, Arthroscopy\",\"volume\":\" \",\"pages\":\"274-285\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11716334/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Knee Surgery, Sports Traumatology, Arthroscopy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/ksa.12299\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery, Sports Traumatology, Arthroscopy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ksa.12299","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Non-invasive quantitative assessment of induced component displacement can safely and accurately diagnose tibial component loosening in patients: A prospective diagnostic study.
Purpose: Aseptic loosening often requires major, expensive and invasive revision surgery. Current diagnostic modalities merely show indirect signs of loosening. A recent proof of concept study proposed a non-invasive technique for the quantitative and visual assessment of implant movement as a diagnostic aid for tibial component loosening. The primary research question addressed is whether this novel diagnostic modality can safely and effectively aid the diagnosis of aseptic loosening.
Methods: This clinical study included patients suspected of aseptic total knee arthroplasty (TKA) loosening listed for revision surgery and asymptomatic patients. Safety was evaluated using a numerical rating scale (NRS) for discomfort and by registration of adverse events. Feasibility was assessed by recording the duration and ease of the procedure. Intra- and interrater reliability were evaluated. In symptomatic patients, diagnostic accuracy metrics were evaluated with intra-operative assessment as a reference test.
Results: In total, 34 symptomatic and 38 asymptomatic knees with a TKA were analysed. The median NRS for discomfort during loading was 6 (interquartile range [IQR]: 3.75-7.00) in symptomatic patients and 2 (IQR: 1.00-3.00) in asymptomatic patients. No adverse events were reported. The majority of users found the use of the loading device easy. The median time spent in the computed tomography room was 9 min (IQR: 8.00-11.00). Excellent to good intra- and interrater reliabilities were achieved. Diagnostic accuracy analysis resulted in a sensitivity of 0.91 (95% confidence interval [CI]: 0.72-0.97) and a specificity of 0.72 (95% CI: 0.43-0.90).
Conclusions: The proposed diagnostic method is safe, feasible, reliable and accurate in aiding the diagnosis of aseptic tibial component loosening.
期刊介绍:
Few other areas of orthopedic surgery and traumatology have undergone such a dramatic evolution in the last 10 years as knee surgery, arthroscopy and sports traumatology. Ranked among the top 33% of journals in both Orthopedics and Sports Sciences, the goal of this European journal is to publish papers about innovative knee surgery, sports trauma surgery and arthroscopy. Each issue features a series of peer-reviewed articles that deal with diagnosis and management and with basic research. Each issue also contains at least one review article about an important clinical problem. Case presentations or short notes about technical innovations are also accepted for publication.
The articles cover all aspects of knee surgery and all types of sports trauma; in addition, epidemiology, diagnosis, treatment and prevention, and all types of arthroscopy (not only the knee but also the shoulder, elbow, wrist, hip, ankle, etc.) are addressed. Articles on new diagnostic techniques such as MRI and ultrasound and high-quality articles about the biomechanics of joints, muscles and tendons are included. Although this is largely a clinical journal, it is also open to basic research with clinical relevance.
Because the journal is supported by a distinguished European Editorial Board, assisted by an international Advisory Board, you can be assured that the journal maintains the highest standards.
Official Clinical Journal of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA).