{"title":"混凝土中的紧固与岩体中的紧固--比较测定混凝土中人为制造的不连续面的拉拔荷载","authors":"O. Zeman, K. Voit, S. Lamplmair‐Irsigler","doi":"10.1002/suco.202400059","DOIUrl":null,"url":null,"abstract":"Possible discontinuities in the subsurface have a major impact on the load‐bearing behavior of post‐installed fastenings. For concrete, the behavior of post‐installed anchors and thus their design can be clearly addressed as concrete is assumed as a homogeneous fastening substrate. This is valid except, for example, in the area of building joints and at joints of precast concrete elements, where the formation of structural joints inevitably occurs and which basically correspond to a separation surface. In contrast, rock mass is characterized by the rock type, but is generally also significantly influenced by its discontinuities. These play a decisive role concerning rock mass stability and show a great impact on the load‐bearing capacity of rock, especially for fasteners with a shallow embedment depth. It is to be assumed that the same also applies to separating surfaces in concrete. Furthermore, the question arises as to the non‐destructive preliminary detectability of such weak zones. For carrying out a comparative study under controlled conditions, artificial interfaces of different geometries were generated in concrete in laboratory tests by inserting PTFE layers at different positions of the test member. Pull‐out tests of post‐installed fastening systems were carried out in their vicinity to determine the load transfer as well as the failure mode. It could be shown that discontinuities have a negative effect on pull‐out loads not only in the rock mass, but also in concrete. However, detection of these by means of a rebound hammer was only possible in the rock mass.","PeriodicalId":21988,"journal":{"name":"Structural Concrete","volume":"41 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fastening in concrete vs. rock mass—Comparative determination of pull‐out loads for artificially created discontinuities in concrete\",\"authors\":\"O. Zeman, K. Voit, S. Lamplmair‐Irsigler\",\"doi\":\"10.1002/suco.202400059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Possible discontinuities in the subsurface have a major impact on the load‐bearing behavior of post‐installed fastenings. For concrete, the behavior of post‐installed anchors and thus their design can be clearly addressed as concrete is assumed as a homogeneous fastening substrate. This is valid except, for example, in the area of building joints and at joints of precast concrete elements, where the formation of structural joints inevitably occurs and which basically correspond to a separation surface. In contrast, rock mass is characterized by the rock type, but is generally also significantly influenced by its discontinuities. These play a decisive role concerning rock mass stability and show a great impact on the load‐bearing capacity of rock, especially for fasteners with a shallow embedment depth. It is to be assumed that the same also applies to separating surfaces in concrete. Furthermore, the question arises as to the non‐destructive preliminary detectability of such weak zones. For carrying out a comparative study under controlled conditions, artificial interfaces of different geometries were generated in concrete in laboratory tests by inserting PTFE layers at different positions of the test member. Pull‐out tests of post‐installed fastening systems were carried out in their vicinity to determine the load transfer as well as the failure mode. It could be shown that discontinuities have a negative effect on pull‐out loads not only in the rock mass, but also in concrete. However, detection of these by means of a rebound hammer was only possible in the rock mass.\",\"PeriodicalId\":21988,\"journal\":{\"name\":\"Structural Concrete\",\"volume\":\"41 1\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-05-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Concrete\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/suco.202400059\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Concrete","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/suco.202400059","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Fastening in concrete vs. rock mass—Comparative determination of pull‐out loads for artificially created discontinuities in concrete
Possible discontinuities in the subsurface have a major impact on the load‐bearing behavior of post‐installed fastenings. For concrete, the behavior of post‐installed anchors and thus their design can be clearly addressed as concrete is assumed as a homogeneous fastening substrate. This is valid except, for example, in the area of building joints and at joints of precast concrete elements, where the formation of structural joints inevitably occurs and which basically correspond to a separation surface. In contrast, rock mass is characterized by the rock type, but is generally also significantly influenced by its discontinuities. These play a decisive role concerning rock mass stability and show a great impact on the load‐bearing capacity of rock, especially for fasteners with a shallow embedment depth. It is to be assumed that the same also applies to separating surfaces in concrete. Furthermore, the question arises as to the non‐destructive preliminary detectability of such weak zones. For carrying out a comparative study under controlled conditions, artificial interfaces of different geometries were generated in concrete in laboratory tests by inserting PTFE layers at different positions of the test member. Pull‐out tests of post‐installed fastening systems were carried out in their vicinity to determine the load transfer as well as the failure mode. It could be shown that discontinuities have a negative effect on pull‐out loads not only in the rock mass, but also in concrete. However, detection of these by means of a rebound hammer was only possible in the rock mass.
期刊介绍:
Structural Concrete, the official journal of the fib, provides conceptual and procedural guidance in the field of concrete construction, and features peer-reviewed papers, keynote research and industry news covering all aspects of the design, construction, performance in service and demolition of concrete structures.
Main topics:
design, construction, performance in service, conservation (assessment, maintenance, strengthening) and demolition of concrete structures
research about the behaviour of concrete structures
development of design methods
fib Model Code
sustainability of concrete structures.