复合剪力墙和承重夹芯板的扭转行为:实验研究

IF 3 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Structural Concrete Pub Date : 2024-05-31 DOI:10.1002/suco.202300764
Haluk Görkem Alcan, Abdulkadir Cüneyt Aydın
{"title":"复合剪力墙和承重夹芯板的扭转行为:实验研究","authors":"Haluk Görkem Alcan, Abdulkadir Cüneyt Aydın","doi":"10.1002/suco.202300764","DOIUrl":null,"url":null,"abstract":"This study aims to experimentally investigate the torsional behavior of acrylic latex polymer and alkali‐resistant glass fiber‐reinforced composite shear walls and load‐bearing sandwich panels. Also, this study was aimed to experimentally examine the changes in the torsional moment capacities, twist angle values, energy dissipation capacities, ductility index, and rigidity of the samples for the presence of the additives added to concrete, size, presence of reinforcement in sandwich panels, and effect of sandwich panels. Within the scope of this work, a control sample, two composite shear walls, and two sandwich panels were produced (1500 × 1200 × 150 mm). While adding 5% acrylic latex to the concrete phase of one of the composite shear wall groups, in the other group, both 5% acrylic latex and 1% alkali‐resistant glass fibers were added to the concrete. While the core structure of the sandwich panel group is reinforced, the other group is produced without reinforcement. A total of 10 samples were loaded out of the plane and a torsional moment is created. As a result of the experiment, the torsional moment, twist angle, and energy dissipation capacities were increased for the samples with acrylic latex and alkali‐resistant glass fiber. While glass fibers increased the ductility index of the test samples, they decreased the stiffness value. Acrylic latex, on the other hand, does not have much effect on the ductility index and stiffness value and increased its energy dissipation capacity. Reinforced sandwich panel samples presented greater torsional moment capacities and stiffnesses compared to composite walls, and less ultimate twist angles and energy dissipation capacities. In addition, although the experimental results of the sandwich panels without reinforcement are lower than the other groups, these also showed load‐bearing capability under the effect of the torsional moment.","PeriodicalId":21988,"journal":{"name":"Structural Concrete","volume":"98 1","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Torsional behavior of composite shear walls and load‐bearing sandwich panels: An experimental investigation\",\"authors\":\"Haluk Görkem Alcan, Abdulkadir Cüneyt Aydın\",\"doi\":\"10.1002/suco.202300764\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study aims to experimentally investigate the torsional behavior of acrylic latex polymer and alkali‐resistant glass fiber‐reinforced composite shear walls and load‐bearing sandwich panels. Also, this study was aimed to experimentally examine the changes in the torsional moment capacities, twist angle values, energy dissipation capacities, ductility index, and rigidity of the samples for the presence of the additives added to concrete, size, presence of reinforcement in sandwich panels, and effect of sandwich panels. Within the scope of this work, a control sample, two composite shear walls, and two sandwich panels were produced (1500 × 1200 × 150 mm). While adding 5% acrylic latex to the concrete phase of one of the composite shear wall groups, in the other group, both 5% acrylic latex and 1% alkali‐resistant glass fibers were added to the concrete. While the core structure of the sandwich panel group is reinforced, the other group is produced without reinforcement. A total of 10 samples were loaded out of the plane and a torsional moment is created. As a result of the experiment, the torsional moment, twist angle, and energy dissipation capacities were increased for the samples with acrylic latex and alkali‐resistant glass fiber. While glass fibers increased the ductility index of the test samples, they decreased the stiffness value. Acrylic latex, on the other hand, does not have much effect on the ductility index and stiffness value and increased its energy dissipation capacity. Reinforced sandwich panel samples presented greater torsional moment capacities and stiffnesses compared to composite walls, and less ultimate twist angles and energy dissipation capacities. In addition, although the experimental results of the sandwich panels without reinforcement are lower than the other groups, these also showed load‐bearing capability under the effect of the torsional moment.\",\"PeriodicalId\":21988,\"journal\":{\"name\":\"Structural Concrete\",\"volume\":\"98 1\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Concrete\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1002/suco.202300764\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Concrete","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/suco.202300764","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在通过实验研究丙烯酸乳胶聚合物和耐碱玻璃纤维增强复合剪力墙和承重夹芯板的扭转行为。此外,本研究还旨在通过实验研究混凝土中添加的添加剂、尺寸、夹层板中是否有钢筋以及夹层板的影响对样品的扭转力矩容量、扭转角值、能量耗散容量、延展性指数和刚度的变化。在这项工作的范围内,制作了一个对照样本、两个复合剪力墙和两个夹芯板(1500 × 1200 × 150 毫米)。其中一组复合剪力墙的混凝土阶段添加了 5%的丙烯酸乳胶,另一组则在混凝土中添加了 5%的丙烯酸乳胶和 1%的耐碱玻璃纤维。夹芯板组的核心结构得到了加固,而另一组则没有加固。共对 10 个样本进行了平面外加载,并产生了扭转力矩。实验结果表明,使用丙烯酸乳胶和耐碱玻璃纤维的样品的扭转力矩、扭转角和能量耗散能力都有所提高。虽然玻璃纤维提高了测试样品的延展性指数,但却降低了刚度值。另一方面,丙烯酸胶乳对延展性指数和刚度值的影响不大,却提高了能量耗散能力。与复合墙体相比,增强夹芯板样品的扭转力矩能力和刚度更大,而极限扭转角和耗能能力较小。此外,虽然没有加固的夹芯板的实验结果低于其他组别,但这些夹芯板在扭矩作用下也显示出了承载能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Torsional behavior of composite shear walls and load‐bearing sandwich panels: An experimental investigation
This study aims to experimentally investigate the torsional behavior of acrylic latex polymer and alkali‐resistant glass fiber‐reinforced composite shear walls and load‐bearing sandwich panels. Also, this study was aimed to experimentally examine the changes in the torsional moment capacities, twist angle values, energy dissipation capacities, ductility index, and rigidity of the samples for the presence of the additives added to concrete, size, presence of reinforcement in sandwich panels, and effect of sandwich panels. Within the scope of this work, a control sample, two composite shear walls, and two sandwich panels were produced (1500 × 1200 × 150 mm). While adding 5% acrylic latex to the concrete phase of one of the composite shear wall groups, in the other group, both 5% acrylic latex and 1% alkali‐resistant glass fibers were added to the concrete. While the core structure of the sandwich panel group is reinforced, the other group is produced without reinforcement. A total of 10 samples were loaded out of the plane and a torsional moment is created. As a result of the experiment, the torsional moment, twist angle, and energy dissipation capacities were increased for the samples with acrylic latex and alkali‐resistant glass fiber. While glass fibers increased the ductility index of the test samples, they decreased the stiffness value. Acrylic latex, on the other hand, does not have much effect on the ductility index and stiffness value and increased its energy dissipation capacity. Reinforced sandwich panel samples presented greater torsional moment capacities and stiffnesses compared to composite walls, and less ultimate twist angles and energy dissipation capacities. In addition, although the experimental results of the sandwich panels without reinforcement are lower than the other groups, these also showed load‐bearing capability under the effect of the torsional moment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Structural Concrete
Structural Concrete CONSTRUCTION & BUILDING TECHNOLOGY-ENGINEERING, CIVIL
CiteScore
5.60
自引率
15.60%
发文量
284
审稿时长
3 months
期刊介绍: Structural Concrete, the official journal of the fib, provides conceptual and procedural guidance in the field of concrete construction, and features peer-reviewed papers, keynote research and industry news covering all aspects of the design, construction, performance in service and demolition of concrete structures. Main topics: design, construction, performance in service, conservation (assessment, maintenance, strengthening) and demolition of concrete structures research about the behaviour of concrete structures development of design methods fib Model Code sustainability of concrete structures.
期刊最新文献
Development of a new analytical model for circular concrete ring segments with dry joints under combined effects Fiber orientation and orientation factors in steel fiber‐reinforced concrete beams with hybrid fibers: A critical review Load‐path analysis of transverse tensile stresses in multiple‐pile caps Mechanical behavior of prestressed UHPC wind turbine tower columns under combined axial compression and bending Experimental investigation on mechanical property and hydration process of sintered sludge cement paste at different water‐binder ratios and curing ages
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1