Patrick Morse MD, Kaleigh F. Roberts MD, PhD, Nicholas C. Spies MD, Vijayalakshmi Padmanabhan MPH, MBBS
{"title":"甲状腺细针穿刺的流程改进:标准化涂片数量,提高充分性和诊断率。","authors":"Patrick Morse MD, Kaleigh F. Roberts MD, PhD, Nicholas C. Spies MD, Vijayalakshmi Padmanabhan MPH, MBBS","doi":"10.1002/dc.25360","DOIUrl":null,"url":null,"abstract":"<p>Fine-needle aspiration (FNA) is a safe, cost-effective diagnostic procedure used in the evaluation of thyroid nodules. The number of thyroid FNAs has dramatically increased over the past few years. In the absence of standardized procedures regarding the number of needle passes needed for diagnosis and the lack of clarity on the use of conventional smears (CS) versus liquid-based preparations (LBP), the demand of thyroid FNAs has led to increased workload on cytology laboratories, which can negatively affect patient safety. We implemented a standardized two needle passes for CS and collection of all needle rinses and additional pass material in CytoRich Red for ThinPrep LBP and compared the non-diagnostic and diagnostic rates before and after this intervention. There were 290 pre-intervention cases and 348 post-intervention cases; of which, there were 17 (5.9%) non-diagnostic cases of the pre-intervention group and 27 (7.8) non-diagnostic cases of the post-intervention group. There was no statistically significant difference in non-diagnostic and diagnostic rates before and after the change (<i>p</i> = 0.347 by two-tailed <i>Z</i> test).</p>","PeriodicalId":11349,"journal":{"name":"Diagnostic Cytopathology","volume":"52 9","pages":"519-523"},"PeriodicalIF":1.0000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Process improvement in thyroid fine needle aspiration: Standardizing number of smears for enhanced adequacy and diagnosis\",\"authors\":\"Patrick Morse MD, Kaleigh F. Roberts MD, PhD, Nicholas C. Spies MD, Vijayalakshmi Padmanabhan MPH, MBBS\",\"doi\":\"10.1002/dc.25360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Fine-needle aspiration (FNA) is a safe, cost-effective diagnostic procedure used in the evaluation of thyroid nodules. The number of thyroid FNAs has dramatically increased over the past few years. In the absence of standardized procedures regarding the number of needle passes needed for diagnosis and the lack of clarity on the use of conventional smears (CS) versus liquid-based preparations (LBP), the demand of thyroid FNAs has led to increased workload on cytology laboratories, which can negatively affect patient safety. We implemented a standardized two needle passes for CS and collection of all needle rinses and additional pass material in CytoRich Red for ThinPrep LBP and compared the non-diagnostic and diagnostic rates before and after this intervention. There were 290 pre-intervention cases and 348 post-intervention cases; of which, there were 17 (5.9%) non-diagnostic cases of the pre-intervention group and 27 (7.8) non-diagnostic cases of the post-intervention group. There was no statistically significant difference in non-diagnostic and diagnostic rates before and after the change (<i>p</i> = 0.347 by two-tailed <i>Z</i> test).</p>\",\"PeriodicalId\":11349,\"journal\":{\"name\":\"Diagnostic Cytopathology\",\"volume\":\"52 9\",\"pages\":\"519-523\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic Cytopathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/dc.25360\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic Cytopathology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/dc.25360","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Process improvement in thyroid fine needle aspiration: Standardizing number of smears for enhanced adequacy and diagnosis
Fine-needle aspiration (FNA) is a safe, cost-effective diagnostic procedure used in the evaluation of thyroid nodules. The number of thyroid FNAs has dramatically increased over the past few years. In the absence of standardized procedures regarding the number of needle passes needed for diagnosis and the lack of clarity on the use of conventional smears (CS) versus liquid-based preparations (LBP), the demand of thyroid FNAs has led to increased workload on cytology laboratories, which can negatively affect patient safety. We implemented a standardized two needle passes for CS and collection of all needle rinses and additional pass material in CytoRich Red for ThinPrep LBP and compared the non-diagnostic and diagnostic rates before and after this intervention. There were 290 pre-intervention cases and 348 post-intervention cases; of which, there were 17 (5.9%) non-diagnostic cases of the pre-intervention group and 27 (7.8) non-diagnostic cases of the post-intervention group. There was no statistically significant difference in non-diagnostic and diagnostic rates before and after the change (p = 0.347 by two-tailed Z test).
期刊介绍:
Diagnostic Cytopathology is intended to provide a forum for the exchange of information in the field of cytopathology, with special emphasis on the practical, clinical aspects of the discipline. The editors invite original scientific articles, as well as special review articles, feature articles, and letters to the editor, from laboratory professionals engaged in the practice of cytopathology. Manuscripts are accepted for publication on the basis of scientific merit, practical significance, and suitability for publication in a journal dedicated to this discipline. Original articles can be considered only with the understanding that they have never been published before and that they have not been submitted for simultaneous review to another publication.