{"title":"温度对水泥浆稠化时间特性的影响","authors":"J. Anaele, I. Otaraku","doi":"10.24940/theijst/2020/v8/i3/st2003-018","DOIUrl":null,"url":null,"abstract":"This study was carried out using API recommended practice 13B-2 in a cement laboratory, and the essence was to establish the effect of an increase in temperature on the thickening time of cement slurry the test was carried out at different temperatures of 80 o F, 100 o F, 120 o F, 140 o F and 160 o F and retarder concentrations of 0.03gal/sk, 0.07 gal/sk, and 0.10 gal/sk. The test results obtained at various concentrations and corresponding temperatures showed that there is a decrease in thickening time at 100BC as the temperature increases, at concentrations of 0.03 gal/sk, 0.07gal/sk, and 0.1gal/sk and temperature of 80 o F the thickening time were 428minutes, 561minutes, and 723minutes, while at a temperature of 160 o F the thickening time were 173minutes, 233minutes, and 297minutes.This, therefore, shows that temperature is a major factor in the slurry design and it has a significant effect on the thickening time of cement slurry.","PeriodicalId":231256,"journal":{"name":"The International Journal of Science & Technoledge","volume":" 61","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Temperature on the Thickening Time Property of Cement Slurry\",\"authors\":\"J. Anaele, I. Otaraku\",\"doi\":\"10.24940/theijst/2020/v8/i3/st2003-018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study was carried out using API recommended practice 13B-2 in a cement laboratory, and the essence was to establish the effect of an increase in temperature on the thickening time of cement slurry the test was carried out at different temperatures of 80 o F, 100 o F, 120 o F, 140 o F and 160 o F and retarder concentrations of 0.03gal/sk, 0.07 gal/sk, and 0.10 gal/sk. The test results obtained at various concentrations and corresponding temperatures showed that there is a decrease in thickening time at 100BC as the temperature increases, at concentrations of 0.03 gal/sk, 0.07gal/sk, and 0.1gal/sk and temperature of 80 o F the thickening time were 428minutes, 561minutes, and 723minutes, while at a temperature of 160 o F the thickening time were 173minutes, 233minutes, and 297minutes.This, therefore, shows that temperature is a major factor in the slurry design and it has a significant effect on the thickening time of cement slurry.\",\"PeriodicalId\":231256,\"journal\":{\"name\":\"The International Journal of Science & Technoledge\",\"volume\":\" 61\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International Journal of Science & Technoledge\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24940/theijst/2020/v8/i3/st2003-018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International Journal of Science & Technoledge","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24940/theijst/2020/v8/i3/st2003-018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
这项研究是在一个水泥实验室中采用 API 推荐的做法 13B-2 进行的,其主要目的是确定温度升高对水泥浆稠化时间的影响,测试在不同的温度下进行,温度分别为 80 o F、100 o F、120 o F、140 o F 和 160 o F,缓凝剂浓度分别为 0.03 gal/sk、0.07 gal/sk 和 0.10 gal/sk。在不同浓度和相应温度下进行的测试结果表明,随着温度的升高,100BC 的增稠时间会缩短,浓度为 0.03 加仑/平方英寸、0.07 加仑/平方英寸和 0.因此,这表明温度是水泥浆设计中的一个主要因素,对水泥浆的稠化时间有显著影响。
Effect of Temperature on the Thickening Time Property of Cement Slurry
This study was carried out using API recommended practice 13B-2 in a cement laboratory, and the essence was to establish the effect of an increase in temperature on the thickening time of cement slurry the test was carried out at different temperatures of 80 o F, 100 o F, 120 o F, 140 o F and 160 o F and retarder concentrations of 0.03gal/sk, 0.07 gal/sk, and 0.10 gal/sk. The test results obtained at various concentrations and corresponding temperatures showed that there is a decrease in thickening time at 100BC as the temperature increases, at concentrations of 0.03 gal/sk, 0.07gal/sk, and 0.1gal/sk and temperature of 80 o F the thickening time were 428minutes, 561minutes, and 723minutes, while at a temperature of 160 o F the thickening time were 173minutes, 233minutes, and 297minutes.This, therefore, shows that temperature is a major factor in the slurry design and it has a significant effect on the thickening time of cement slurry.