评估青少年精英足球运动员的最大摄氧量:智能手表技术、Yoyo 间歇恢复测试 2 和呼吸气体分析的比较分析

Peter Düking, Ludwig Ruf, Stefan Altmann, Maximiliane Thron, Philipp Kunz, B. Sperlich
{"title":"评估青少年精英足球运动员的最大摄氧量:智能手表技术、Yoyo 间歇恢复测试 2 和呼吸气体分析的比较分析","authors":"Peter Düking, Ludwig Ruf, Stefan Altmann, Maximiliane Thron, Philipp Kunz, B. Sperlich","doi":"10.52082/jssm.2024.351","DOIUrl":null,"url":null,"abstract":"The maximum oxygen uptake (VO2max) is a critical factor for endurance performance in soccer. Novel wearable technology may allow frequent assessment of V̇O2max during non-fatiguing warm-up runs of soccer players with minimal interference to soccer practice. The aim of this study was to assess the validity of VO2max provided by a consumer grade smartwatch (Garmin Forerunner 245, Garmin, Olathe, USA, Software:13.00) and the YoYo Intermittent Recovery Run 2 (YYIR2) by comparing it with respiratory gas analysis. 24 trained male youth soccer players performed different tests to assess VO2max: i) a treadmill test employing respiratory gas analysis, ii) YYIR2 and iii) during a non-fatiguing warm-up run of 10 min wearing a smartwatch as recommended by the device-manufacturer on 3 different days within 2 weeks. As the device-manufacturer indicates that validity of smartwatch-derived VO2max may differ with an increase in runs, 16 players performed a second run with the smartwatch to test this claim. The main evidence revealed that the smartwatch showed an ICC of 0.37 [95% CI: -0.25; 0.71] a mean absolute percentage error (MAPE) of 5.58% after one run, as well as an ICC of 0.54 [95% CI: -0.3; 8.4] and a MAPE of 1.06% after the second run with the smartwatch. The YYIR2 showed an ICC of 0.17 [95% CI: -5.7; 0.6]; and MAPE of 4.2%. When using the smartwatch for VO2max assessment in a non-fatiguing run as a warm-up, as suggested by the device manufacturer before soccer practice, the MAPE diminishes after two runs. Therefore, for more accurate VO2max assessment with the smartwatch, we recommend to perform at least two runs to reduce the MAPE and enhance the validity of the findings.","PeriodicalId":506848,"journal":{"name":"Journal of Sports Science and Medicine","volume":"88 10","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Maximum Oxygen Uptake in Elite Youth Soccer Players: A Comparative Analysis of Smartwatch Technology, Yoyo Intermittent Recovery Test 2, and Respiratory Gas Analysis\",\"authors\":\"Peter Düking, Ludwig Ruf, Stefan Altmann, Maximiliane Thron, Philipp Kunz, B. Sperlich\",\"doi\":\"10.52082/jssm.2024.351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The maximum oxygen uptake (VO2max) is a critical factor for endurance performance in soccer. Novel wearable technology may allow frequent assessment of V̇O2max during non-fatiguing warm-up runs of soccer players with minimal interference to soccer practice. The aim of this study was to assess the validity of VO2max provided by a consumer grade smartwatch (Garmin Forerunner 245, Garmin, Olathe, USA, Software:13.00) and the YoYo Intermittent Recovery Run 2 (YYIR2) by comparing it with respiratory gas analysis. 24 trained male youth soccer players performed different tests to assess VO2max: i) a treadmill test employing respiratory gas analysis, ii) YYIR2 and iii) during a non-fatiguing warm-up run of 10 min wearing a smartwatch as recommended by the device-manufacturer on 3 different days within 2 weeks. As the device-manufacturer indicates that validity of smartwatch-derived VO2max may differ with an increase in runs, 16 players performed a second run with the smartwatch to test this claim. The main evidence revealed that the smartwatch showed an ICC of 0.37 [95% CI: -0.25; 0.71] a mean absolute percentage error (MAPE) of 5.58% after one run, as well as an ICC of 0.54 [95% CI: -0.3; 8.4] and a MAPE of 1.06% after the second run with the smartwatch. The YYIR2 showed an ICC of 0.17 [95% CI: -5.7; 0.6]; and MAPE of 4.2%. When using the smartwatch for VO2max assessment in a non-fatiguing run as a warm-up, as suggested by the device manufacturer before soccer practice, the MAPE diminishes after two runs. Therefore, for more accurate VO2max assessment with the smartwatch, we recommend to perform at least two runs to reduce the MAPE and enhance the validity of the findings.\",\"PeriodicalId\":506848,\"journal\":{\"name\":\"Journal of Sports Science and Medicine\",\"volume\":\"88 10\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sports Science and Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52082/jssm.2024.351\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sports Science and Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52082/jssm.2024.351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

最大摄氧量(VO2max)是足球耐力表现的关键因素。新型可穿戴技术可以在足球运动员进行非疲劳性热身跑步时频繁评估最大摄氧量,并将对足球训练的干扰降至最低。本研究旨在评估消费级智能手表(Garmin Forerunner 245,Garmin,Olathe,USA,Software:13.00)和 "悠悠间歇恢复跑 2"(YYIR2)提供的 VO2max 值的有效性,并将其与呼吸气体分析进行比较。24 名训练有素的男性青少年足球运动员进行了不同的测试以评估最大氧饱和度:i) 采用呼吸气体分析的跑步机测试;ii) YYIR2;iii) 在 2 周内的 3 个不同的日子,按照设备制造商的建议,佩戴智能手表进行 10 分钟的非疲劳热身跑。由于设备制造商指出,智能手表得出的 VO2max 值的有效性可能会随着跑步次数的增加而不同,因此 16 名运动员佩戴智能手表进行了第二次跑步,以验证这一说法。主要证据显示,智能手表在一次跑步后的 ICC 为 0.37 [95% CI: -0.25; 0.71],平均绝对百分比误差 (MAPE) 为 5.58%,而使用智能手表进行第二次跑步后的 ICC 为 0.54 [95% CI: -0.3; 8.4],平均绝对百分比误差 (MAPE) 为 1.06%。YYIR2 的 ICC 为 0.17 [95% CI: -5.7; 0.6],MAPE 为 4.2%。按照设备制造商的建议,在足球训练前使用智能手表进行非疲劳跑热身,评估 VO2max 时,MAPE 会在两次跑后减小。因此,为了使用智能手表进行更准确的 VO2max 评估,我们建议至少进行两次跑步,以降低 MAPE,提高评估结果的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of Maximum Oxygen Uptake in Elite Youth Soccer Players: A Comparative Analysis of Smartwatch Technology, Yoyo Intermittent Recovery Test 2, and Respiratory Gas Analysis
The maximum oxygen uptake (VO2max) is a critical factor for endurance performance in soccer. Novel wearable technology may allow frequent assessment of V̇O2max during non-fatiguing warm-up runs of soccer players with minimal interference to soccer practice. The aim of this study was to assess the validity of VO2max provided by a consumer grade smartwatch (Garmin Forerunner 245, Garmin, Olathe, USA, Software:13.00) and the YoYo Intermittent Recovery Run 2 (YYIR2) by comparing it with respiratory gas analysis. 24 trained male youth soccer players performed different tests to assess VO2max: i) a treadmill test employing respiratory gas analysis, ii) YYIR2 and iii) during a non-fatiguing warm-up run of 10 min wearing a smartwatch as recommended by the device-manufacturer on 3 different days within 2 weeks. As the device-manufacturer indicates that validity of smartwatch-derived VO2max may differ with an increase in runs, 16 players performed a second run with the smartwatch to test this claim. The main evidence revealed that the smartwatch showed an ICC of 0.37 [95% CI: -0.25; 0.71] a mean absolute percentage error (MAPE) of 5.58% after one run, as well as an ICC of 0.54 [95% CI: -0.3; 8.4] and a MAPE of 1.06% after the second run with the smartwatch. The YYIR2 showed an ICC of 0.17 [95% CI: -5.7; 0.6]; and MAPE of 4.2%. When using the smartwatch for VO2max assessment in a non-fatiguing run as a warm-up, as suggested by the device manufacturer before soccer practice, the MAPE diminishes after two runs. Therefore, for more accurate VO2max assessment with the smartwatch, we recommend to perform at least two runs to reduce the MAPE and enhance the validity of the findings.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimal Prescription for Superior Outcomes: A Comparative Analysis of Inter-Individual Variability in Adaptations to Small-Sided Games and Short Sprint Interval Training in Young Basketball Players Combined Aerobic and Resistance Training Improves Body Composition, Alters Cardiometabolic Risk, and Ameliorates Cancer-Related Indicators in Breast Cancer Patients and Survivors with Overweight/Obesity: A Systematic Review and Meta-Analysis of Randomized Controlled Trials Thoracolumbar Fascia and Lumbar Muscle Stiffness in Athletes with A History of Hamstring Injury Race Dynamics in Triathlon Mixed-Team-Relay Meaningfully Changes with The New Regulation Towards Paris 2024 Neuromechanical Differences between Pronated and Supinated Forearm Positions during Upper-Body Wingate Tests
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1