Kannika Srisomthrong, Jom Suwanno, Nuntaporn Klinjun, Juk Suwanno, Matthew Kelly
{"title":"泰语版慢性病自我护理量表 4c 在中风患者中的心理测试。","authors":"Kannika Srisomthrong, Jom Suwanno, Nuntaporn Klinjun, Juk Suwanno, Matthew Kelly","doi":"10.1097/JCN.0000000000001111","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Self-Care of Chronic Illness Inventory version 4c is a non-disease-specific self-care measure used in individuals with multiple chronic conditions. This instrument may be applied to patients with specific diseases such as stroke.</p><p><strong>Objective: </strong>The aim of this study was to evaluate the psychometric properties of the Thai version of the Self-Care of Chronic Illness Inventory version 4c in patients with stroke.</p><p><strong>Methods: </strong>This multicenter, cross-sectional study adhered to the COSMIN (Consensus-based Standards for the Selection of Health Measurement Instruments) guidelines and enrolled patients with stroke from 16 primary care centers in southern Thailand. Structural validity was assessed using confirmatory factor analysis, internal consistency reliability using Cronbach α coefficient and global reliability index, and test-retest reliability using intraclass correlation coefficients.</p><p><strong>Results: </strong>The final analysis included a total of 350 participants. Confirmatory factor analysis supported the 2-factor Self-Care Maintenance scale structure, although the item allocation to the dimensions differed from that of the original model. The Self-Care Monitoring scale demonstrated a 1-factor structure with permitted residual covariance. The Self-Care Management scale maintained a 2-factor structure, similar to that of the original model. Simultaneous confirmatory factor analysis of the combined items supported the general model with the 3 scales. The Self-Care Maintenance scale exhibited marginally adequate α (0.68) and ω (0.66) coefficients, and an adequate composite reliability index (0.79). The other 2 scales demonstrated adequate α (range, 0.79-0.86), ω (range, 0.75-0.86), and composite reliability (range, 0.83-0.86) indices. Intraclass correlation coefficients showed adequate test-retest reliability for all scales (range, 0.76-0.90).</p><p><strong>Conclusions: </strong>The generic self-care measure, Self-Care of Chronic Illness Inventory version 4c, demonstrated strong psychometric properties in patients with stroke. This instrument may be a valuable tool for assessing stroke self-care in Thailand.</p>","PeriodicalId":54868,"journal":{"name":"Journal of Cardiovascular Nursing","volume":" ","pages":"170-181"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Psychometric Testing of the Thai Version of Self-Care of Chronic Illness Inventory Version 4c in Patients With Stroke.\",\"authors\":\"Kannika Srisomthrong, Jom Suwanno, Nuntaporn Klinjun, Juk Suwanno, Matthew Kelly\",\"doi\":\"10.1097/JCN.0000000000001111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Self-Care of Chronic Illness Inventory version 4c is a non-disease-specific self-care measure used in individuals with multiple chronic conditions. This instrument may be applied to patients with specific diseases such as stroke.</p><p><strong>Objective: </strong>The aim of this study was to evaluate the psychometric properties of the Thai version of the Self-Care of Chronic Illness Inventory version 4c in patients with stroke.</p><p><strong>Methods: </strong>This multicenter, cross-sectional study adhered to the COSMIN (Consensus-based Standards for the Selection of Health Measurement Instruments) guidelines and enrolled patients with stroke from 16 primary care centers in southern Thailand. Structural validity was assessed using confirmatory factor analysis, internal consistency reliability using Cronbach α coefficient and global reliability index, and test-retest reliability using intraclass correlation coefficients.</p><p><strong>Results: </strong>The final analysis included a total of 350 participants. Confirmatory factor analysis supported the 2-factor Self-Care Maintenance scale structure, although the item allocation to the dimensions differed from that of the original model. The Self-Care Monitoring scale demonstrated a 1-factor structure with permitted residual covariance. The Self-Care Management scale maintained a 2-factor structure, similar to that of the original model. Simultaneous confirmatory factor analysis of the combined items supported the general model with the 3 scales. The Self-Care Maintenance scale exhibited marginally adequate α (0.68) and ω (0.66) coefficients, and an adequate composite reliability index (0.79). The other 2 scales demonstrated adequate α (range, 0.79-0.86), ω (range, 0.75-0.86), and composite reliability (range, 0.83-0.86) indices. Intraclass correlation coefficients showed adequate test-retest reliability for all scales (range, 0.76-0.90).</p><p><strong>Conclusions: </strong>The generic self-care measure, Self-Care of Chronic Illness Inventory version 4c, demonstrated strong psychometric properties in patients with stroke. This instrument may be a valuable tool for assessing stroke self-care in Thailand.</p>\",\"PeriodicalId\":54868,\"journal\":{\"name\":\"Journal of Cardiovascular Nursing\",\"volume\":\" \",\"pages\":\"170-181\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Nursing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/JCN.0000000000001111\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Nursing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/JCN.0000000000001111","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Psychometric Testing of the Thai Version of Self-Care of Chronic Illness Inventory Version 4c in Patients With Stroke.
Background: Self-Care of Chronic Illness Inventory version 4c is a non-disease-specific self-care measure used in individuals with multiple chronic conditions. This instrument may be applied to patients with specific diseases such as stroke.
Objective: The aim of this study was to evaluate the psychometric properties of the Thai version of the Self-Care of Chronic Illness Inventory version 4c in patients with stroke.
Methods: This multicenter, cross-sectional study adhered to the COSMIN (Consensus-based Standards for the Selection of Health Measurement Instruments) guidelines and enrolled patients with stroke from 16 primary care centers in southern Thailand. Structural validity was assessed using confirmatory factor analysis, internal consistency reliability using Cronbach α coefficient and global reliability index, and test-retest reliability using intraclass correlation coefficients.
Results: The final analysis included a total of 350 participants. Confirmatory factor analysis supported the 2-factor Self-Care Maintenance scale structure, although the item allocation to the dimensions differed from that of the original model. The Self-Care Monitoring scale demonstrated a 1-factor structure with permitted residual covariance. The Self-Care Management scale maintained a 2-factor structure, similar to that of the original model. Simultaneous confirmatory factor analysis of the combined items supported the general model with the 3 scales. The Self-Care Maintenance scale exhibited marginally adequate α (0.68) and ω (0.66) coefficients, and an adequate composite reliability index (0.79). The other 2 scales demonstrated adequate α (range, 0.79-0.86), ω (range, 0.75-0.86), and composite reliability (range, 0.83-0.86) indices. Intraclass correlation coefficients showed adequate test-retest reliability for all scales (range, 0.76-0.90).
Conclusions: The generic self-care measure, Self-Care of Chronic Illness Inventory version 4c, demonstrated strong psychometric properties in patients with stroke. This instrument may be a valuable tool for assessing stroke self-care in Thailand.
期刊介绍:
Official journal of the Preventive Cardiovascular Nurses Association, Journal of Cardiovascular Nursing is one of the leading journals for advanced practice nurses in cardiovascular care, providing thorough coverage of timely topics and information that is extremely practical for daily, on-the-job use. Each issue addresses the physiologic, psychologic, and social needs of cardiovascular patients and their families in a variety of environments. Regular columns include By the Bedside, Progress in Prevention, Pharmacology, Dysrhythmias, and Outcomes Research.