旨在确定艾滋病毒病毒载量结果可靠性的实地研究表明,在南非,延迟检测的影响微乎其微。

IF 1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL African Journal of Laboratory Medicine Pub Date : 2024-05-28 eCollection Date: 2024-01-01 DOI:10.4102/ajlm.v13i1.2364
Diana R Hardie, Howard Newman, Joanna Reid, Nei-Yuan Hsiao, Gert van Zyl, Lucia Hans, Jasantha Odayar, Stephen Korsman
{"title":"旨在确定艾滋病毒病毒载量结果可靠性的实地研究表明,在南非,延迟检测的影响微乎其微。","authors":"Diana R Hardie, Howard Newman, Joanna Reid, Nei-Yuan Hsiao, Gert van Zyl, Lucia Hans, Jasantha Odayar, Stephen Korsman","doi":"10.4102/ajlm.v13i1.2364","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Understanding factors that impact HIV viral load (VL) accuracy in resource-limited settings is key to quality improvement.</p><p><strong>Objective: </strong>We evaluated whether testing delay and specimen storage between 25 °C and 30 °C before testing affected results.</p><p><strong>Methods: </strong>Between November 2019 and June 2023, 249 individuals on antiretroviral therapy, or with newly diagnosed HIV, were recruited from clinics in Cape Town and Gqeberha, South Africa, and three plasma preparation tubes were collected. One tube was tested within 24 h, while the others were stored uncentrifuged at ambient temperatures before testing. Centrifugation and testing of matched samples were performed on Day 4 and Day 7 after collection.</p><p><strong>Results: </strong>Time delay and ambient storage had minimal impact in specimens with a Day 1 VL of > 100 copies/mL. When grouped by Day 1 VL range, 96% - 100% of specimens at Day 4 and 93% - 100% at Day 7 had VLs within 0.5 log copies/mL of the first result. The greatest variability at Days 4 and 7 was observed when the Day 1 VL was < 100 copies/mL. However, there was no trend of increasing difference over time. Of Day 1 specimens with undetectable VL, or VL < 50 copies/mL, 80% had concordant results at Day 4 and 78% at Day 7.</p><p><strong>Conclusion: </strong>These results show that VL is stable in plasma preparation tubes for 7 days when stored at room temperature. There is significant variability in specimens with low VL, but variability is not affected by testing delay.</p><p><strong>What this study adds: </strong>Ideal HIV VL testing conditions are frequently unachievable in resource-limited settings. Data are needed on whether this impacts on the validity of test results. Our results provide reassurance that storage at ambient temperature for up to 7 days before testing does not substantially affect the VL result.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11151376/pdf/","citationCount":"0","resultStr":"{\"title\":\"Field study to determine the reliability of HIV viral load results shows minimal impact of delayed testing in South Africa.\",\"authors\":\"Diana R Hardie, Howard Newman, Joanna Reid, Nei-Yuan Hsiao, Gert van Zyl, Lucia Hans, Jasantha Odayar, Stephen Korsman\",\"doi\":\"10.4102/ajlm.v13i1.2364\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Understanding factors that impact HIV viral load (VL) accuracy in resource-limited settings is key to quality improvement.</p><p><strong>Objective: </strong>We evaluated whether testing delay and specimen storage between 25 °C and 30 °C before testing affected results.</p><p><strong>Methods: </strong>Between November 2019 and June 2023, 249 individuals on antiretroviral therapy, or with newly diagnosed HIV, were recruited from clinics in Cape Town and Gqeberha, South Africa, and three plasma preparation tubes were collected. One tube was tested within 24 h, while the others were stored uncentrifuged at ambient temperatures before testing. Centrifugation and testing of matched samples were performed on Day 4 and Day 7 after collection.</p><p><strong>Results: </strong>Time delay and ambient storage had minimal impact in specimens with a Day 1 VL of > 100 copies/mL. When grouped by Day 1 VL range, 96% - 100% of specimens at Day 4 and 93% - 100% at Day 7 had VLs within 0.5 log copies/mL of the first result. The greatest variability at Days 4 and 7 was observed when the Day 1 VL was < 100 copies/mL. However, there was no trend of increasing difference over time. Of Day 1 specimens with undetectable VL, or VL < 50 copies/mL, 80% had concordant results at Day 4 and 78% at Day 7.</p><p><strong>Conclusion: </strong>These results show that VL is stable in plasma preparation tubes for 7 days when stored at room temperature. There is significant variability in specimens with low VL, but variability is not affected by testing delay.</p><p><strong>What this study adds: </strong>Ideal HIV VL testing conditions are frequently unachievable in resource-limited settings. Data are needed on whether this impacts on the validity of test results. Our results provide reassurance that storage at ambient temperature for up to 7 days before testing does not substantially affect the VL result.</p>\",\"PeriodicalId\":45412,\"journal\":{\"name\":\"African Journal of Laboratory Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11151376/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4102/ajlm.v13i1.2364\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v13i1.2364","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:了解在资源有限的环境中影响 HIV 病毒载量(VL)准确性的因素是提高质量的关键:在资源有限的环境中,了解影响 HIV 病毒载量(VL)准确性的因素是提高质量的关键:我们评估了检测延迟和检测前标本在 25 °C 和 30 °C 之间的储存是否会影响检测结果:2019年11月至2023年6月期间,我们从南非开普敦和盖贝哈的诊所招募了249名正在接受抗逆转录病毒治疗或新确诊感染艾滋病毒的患者,并收集了三管血浆制备样本。其中一管在 24 小时内进行检测,其他血浆在检测前未经离心储存在环境温度下。采集后第 4 天和第 7 天对匹配样本进行离心和检测:结果:时间延迟和常温保存对第 1 天 VL > 100 拷贝/毫升的样本影响很小。如果按第 1 天 VL 范围分组,第 4 天 96% - 100% 的标本和第 7 天 93% - 100% 的标本的 VL 都在首次结果的 0.5 log copies/mL 以内。当第 1 天的 VL 小于 100 拷贝/毫升时,第 4 天和第 7 天的变异性最大。然而,随着时间的推移,差异没有增加的趋势。在第 1 天检测不到 VL 或 VL < 50 拷贝/毫升的标本中,第 4 天 80% 的结果一致,第 7 天 78% 的结果一致:这些结果表明,血浆制备试管在室温下保存 7 天,VL 是稳定的。低 VL 标本的变异性很大,但变异性不受检测延迟的影响:本研究的补充:在资源有限的环境中,理想的 HIV VL 检测条件往往无法实现。我们需要数据来说明这是否会影响检测结果的有效性。我们的研究结果再次证明,检测前在环境温度下储存 7 天不会对 VL 结果产生重大影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Field study to determine the reliability of HIV viral load results shows minimal impact of delayed testing in South Africa.

Background: Understanding factors that impact HIV viral load (VL) accuracy in resource-limited settings is key to quality improvement.

Objective: We evaluated whether testing delay and specimen storage between 25 °C and 30 °C before testing affected results.

Methods: Between November 2019 and June 2023, 249 individuals on antiretroviral therapy, or with newly diagnosed HIV, were recruited from clinics in Cape Town and Gqeberha, South Africa, and three plasma preparation tubes were collected. One tube was tested within 24 h, while the others were stored uncentrifuged at ambient temperatures before testing. Centrifugation and testing of matched samples were performed on Day 4 and Day 7 after collection.

Results: Time delay and ambient storage had minimal impact in specimens with a Day 1 VL of > 100 copies/mL. When grouped by Day 1 VL range, 96% - 100% of specimens at Day 4 and 93% - 100% at Day 7 had VLs within 0.5 log copies/mL of the first result. The greatest variability at Days 4 and 7 was observed when the Day 1 VL was < 100 copies/mL. However, there was no trend of increasing difference over time. Of Day 1 specimens with undetectable VL, or VL < 50 copies/mL, 80% had concordant results at Day 4 and 78% at Day 7.

Conclusion: These results show that VL is stable in plasma preparation tubes for 7 days when stored at room temperature. There is significant variability in specimens with low VL, but variability is not affected by testing delay.

What this study adds: Ideal HIV VL testing conditions are frequently unachievable in resource-limited settings. Data are needed on whether this impacts on the validity of test results. Our results provide reassurance that storage at ambient temperature for up to 7 days before testing does not substantially affect the VL result.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
African Journal of Laboratory Medicine
African Journal of Laboratory Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.70
自引率
9.10%
发文量
53
审稿时长
12 weeks
期刊介绍: The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.
期刊最新文献
Pathobiology of HIV-related metabolic and cardiovascular comorbidities: Towards a unifying mechanism. An audit of the iron status of patients at Chris Hani Baragwanath Academic Hospital, in Johannesburg, South Africa. Carriers of the m.3243A>G variant should not be labelled with an acronym before they have been systematically screened for multisystem disease. Challenges with communication of critical laboratory results in a resource-limited setting in South Africa. Association between coagulation indicators and menorrhagia among women in Kenya.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1