Himanshu Sharma, Ishrat Khan, Varsha Porwal, Haneef Khan, Dr. Himanshu Sharma
{"title":"青壮年瞳孔与角膜缘直径比值与血压和脉搏的关系:观察研究","authors":"Himanshu Sharma, Ishrat Khan, Varsha Porwal, Haneef Khan, Dr. Himanshu Sharma","doi":"10.3126/ajms.v15i6.62572","DOIUrl":null,"url":null,"abstract":"Background: Autonomic function tests play a crucial role in the diagnosis and prognosis of clinical conditions. Although there are multiple autonomic function tests available, there is still a need for rapid and less expensive tests for the benefit of the general population. The pupil-to-limbus diameter (PLD) ratio is one such test that is simple and cost-effective. It uses the principle of pupil dilation and constriction due to the influence of the autonomic neurons’ activity.\n Aims and Objectives: The present study aimed to observe a correlation between PLD ratio with blood pressure and pulse rate in young adults.\nMaterials and Methods: The present study was conducted at the Department of Physiology, Jhalawar Medical College, Jhalawar. The present study was an observational study conducted among 1st-year medical students in the age group of 18–24 years. PLD ratio was measured by the two-box method as described in the literature. After providing 3–5 min of rest, blood pressure and pulse were recorded in the right arm in the sitting position by a digital blood pressure monitor.\nResults: Positive correlation was observed between the PLD ratio of right eye and pulse rate (r=0.9696). There is a weak negative correlation exists between the PLD ratio of right eye and systolic blood pressure (r value=−0.3802).\nConclusion: The study concludes that the PLD ratio correlates with autonomic activity. However, there is a need for a study with large population to confirm the correlation. Furthermore, there is a study to assess the autonomic responses in female participants in different phases of menstrual cycle.","PeriodicalId":8522,"journal":{"name":"Asian Journal of Medical Sciences","volume":"126 36","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Relationship between pupil to limbus diameter ratio with blood pressure and pulse rate in young adults: An observational study\",\"authors\":\"Himanshu Sharma, Ishrat Khan, Varsha Porwal, Haneef Khan, Dr. Himanshu Sharma\",\"doi\":\"10.3126/ajms.v15i6.62572\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Autonomic function tests play a crucial role in the diagnosis and prognosis of clinical conditions. Although there are multiple autonomic function tests available, there is still a need for rapid and less expensive tests for the benefit of the general population. The pupil-to-limbus diameter (PLD) ratio is one such test that is simple and cost-effective. It uses the principle of pupil dilation and constriction due to the influence of the autonomic neurons’ activity.\\n Aims and Objectives: The present study aimed to observe a correlation between PLD ratio with blood pressure and pulse rate in young adults.\\nMaterials and Methods: The present study was conducted at the Department of Physiology, Jhalawar Medical College, Jhalawar. The present study was an observational study conducted among 1st-year medical students in the age group of 18–24 years. PLD ratio was measured by the two-box method as described in the literature. After providing 3–5 min of rest, blood pressure and pulse were recorded in the right arm in the sitting position by a digital blood pressure monitor.\\nResults: Positive correlation was observed between the PLD ratio of right eye and pulse rate (r=0.9696). There is a weak negative correlation exists between the PLD ratio of right eye and systolic blood pressure (r value=−0.3802).\\nConclusion: The study concludes that the PLD ratio correlates with autonomic activity. However, there is a need for a study with large population to confirm the correlation. Furthermore, there is a study to assess the autonomic responses in female participants in different phases of menstrual cycle.\",\"PeriodicalId\":8522,\"journal\":{\"name\":\"Asian Journal of Medical Sciences\",\"volume\":\"126 36\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3126/ajms.v15i6.62572\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/ajms.v15i6.62572","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Relationship between pupil to limbus diameter ratio with blood pressure and pulse rate in young adults: An observational study
Background: Autonomic function tests play a crucial role in the diagnosis and prognosis of clinical conditions. Although there are multiple autonomic function tests available, there is still a need for rapid and less expensive tests for the benefit of the general population. The pupil-to-limbus diameter (PLD) ratio is one such test that is simple and cost-effective. It uses the principle of pupil dilation and constriction due to the influence of the autonomic neurons’ activity.
Aims and Objectives: The present study aimed to observe a correlation between PLD ratio with blood pressure and pulse rate in young adults.
Materials and Methods: The present study was conducted at the Department of Physiology, Jhalawar Medical College, Jhalawar. The present study was an observational study conducted among 1st-year medical students in the age group of 18–24 years. PLD ratio was measured by the two-box method as described in the literature. After providing 3–5 min of rest, blood pressure and pulse were recorded in the right arm in the sitting position by a digital blood pressure monitor.
Results: Positive correlation was observed between the PLD ratio of right eye and pulse rate (r=0.9696). There is a weak negative correlation exists between the PLD ratio of right eye and systolic blood pressure (r value=−0.3802).
Conclusion: The study concludes that the PLD ratio correlates with autonomic activity. However, there is a need for a study with large population to confirm the correlation. Furthermore, there is a study to assess the autonomic responses in female participants in different phases of menstrual cycle.