{"title":"改进[11C]2-(2,6-二氟-4-((2-(N-甲基苯基磺酰胺基)乙基)硫)苯氧基)乙酰胺([11C]K2)的放射合成和自动化,用于谷氨酸α-氨基-3-羟基-5-甲基-4-异恶唑丙酸(AMPA)受体的正电子发射断层成像。","authors":"Jason A. Witek,&nbsp;Mami Horikawa,&nbsp;Bradford D. Henderson,&nbsp;Allen F. Brooks,&nbsp;Peter J. H. Scott,&nbsp;Xia Shao","doi":"10.1002/jlcr.4113","DOIUrl":null,"url":null,"abstract":"<p>A new automated radiosynthesis of [<sup>11</sup>C]2-(2,6-difluoro-4-((2-(<i>N</i>-methylphenylsulfonamido)ethyl)thio)phenoxy)acetamide ([<sup>11</sup>C]K2), a radiopharmaceutical for the glutamate α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid (AMPA) receptor, is reported. Although manual syntheses have been described, these are unsuitable for routine production of larger batches of [<sup>11</sup>C]K2 for (pre)clinical PET imaging applications. To meet demands for the imaging agent from our functional neuroimaging collaborators, herein, we report a current good manufacturing practice (cGMP)-compliant synthesis of [<sup>11</sup>C]K2 using a commercial synthesis module. The new synthesis is fully automated and has been validated for clinical use. The total synthesis time is 33 min from end of bombardment, and the production method provides 2.66 ± 0.3 GBq (71.9 ± 8.6 mCi) of [<sup>11</sup>C]K2 in 97.7 ± 0.5% radiochemical purity and 754.1 ± 231.5 TBq/mmol (20,382.7 ± 6256.1 Ci/mmol) molar activity (<i>n</i> = 3). Batches passed all requisite quality control testing confirming suitability for clinical use.</p>","PeriodicalId":16288,"journal":{"name":"Journal of labelled compounds & radiopharmaceuticals","volume":"67 9","pages":"324-329"},"PeriodicalIF":0.9000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11262959/pdf/","citationCount":"0","resultStr":"{\"title\":\"Improved Radiosynthesis and Automation of [11C]2-(2,6-Difluoro-4-((2-(N-methylphenylsulfonamido)ethyl)thio)phenoxy)acetamide ([11C]K2) for Positron Emission Tomography of the Glutamate α-Amino-3-hydroxy-5-methyl-4-isoxazole Propionic Acid (AMPA) Receptor\",\"authors\":\"Jason A. Witek,&nbsp;Mami Horikawa,&nbsp;Bradford D. Henderson,&nbsp;Allen F. Brooks,&nbsp;Peter J. H. Scott,&nbsp;Xia Shao\",\"doi\":\"10.1002/jlcr.4113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A new automated radiosynthesis of [<sup>11</sup>C]2-(2,6-difluoro-4-((2-(<i>N</i>-methylphenylsulfonamido)ethyl)thio)phenoxy)acetamide ([<sup>11</sup>C]K2), a radiopharmaceutical for the glutamate α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid (AMPA) receptor, is reported. Although manual syntheses have been described, these are unsuitable for routine production of larger batches of [<sup>11</sup>C]K2 for (pre)clinical PET imaging applications. To meet demands for the imaging agent from our functional neuroimaging collaborators, herein, we report a current good manufacturing practice (cGMP)-compliant synthesis of [<sup>11</sup>C]K2 using a commercial synthesis module. The new synthesis is fully automated and has been validated for clinical use. The total synthesis time is 33 min from end of bombardment, and the production method provides 2.66 ± 0.3 GBq (71.9 ± 8.6 mCi) of [<sup>11</sup>C]K2 in 97.7 ± 0.5% radiochemical purity and 754.1 ± 231.5 TBq/mmol (20,382.7 ± 6256.1 Ci/mmol) molar activity (<i>n</i> = 3). Batches passed all requisite quality control testing confirming suitability for clinical use.</p>\",\"PeriodicalId\":16288,\"journal\":{\"name\":\"Journal of labelled compounds & radiopharmaceuticals\",\"volume\":\"67 9\",\"pages\":\"324-329\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11262959/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of labelled compounds & radiopharmaceuticals\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jlcr.4113\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of labelled compounds & radiopharmaceuticals","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jlcr.4113","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

本研究报告了[11C]2-(2,6-二氟-4-((2-(N-甲基苯基磺酰胺基)乙基)硫代)苯氧基)乙酰胺([11C]K2)的一种新的自动放射合成方法,这是一种针对谷氨酸α-氨基-3-羟基-5-甲基-4-异恶唑丙酸(AMPA)受体的放射性药物。虽然已经介绍了人工合成的方法,但这些方法不适合用于临床 PET 成像应用的大批量[11C]K2 的常规生产。为了满足我们的功能神经成像合作者对成像剂的需求,我们在此报告一种符合现行良好生产规范(cGMP)的[11C]K2 合成方法,使用的是一种商用合成模块。新的合成过程完全自动化,并已通过临床使用验证。从轰击结束算起,总合成时间为 33 分钟,该生产方法可提供 2.66 ± 0.3 GBq(71.9 ± 8.6 mCi)的[11C]K2,放射化学纯度为 97.7 ± 0.5%,摩尔活性为 754.1 ± 231.5 TBq/mmol(20,382.7 ± 6256.1 Ci/mmol)(n = 3)。各批次产品均通过了所有必要的质量控制测试,确认适合临床使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improved Radiosynthesis and Automation of [11C]2-(2,6-Difluoro-4-((2-(N-methylphenylsulfonamido)ethyl)thio)phenoxy)acetamide ([11C]K2) for Positron Emission Tomography of the Glutamate α-Amino-3-hydroxy-5-methyl-4-isoxazole Propionic Acid (AMPA) Receptor

A new automated radiosynthesis of [11C]2-(2,6-difluoro-4-((2-(N-methylphenylsulfonamido)ethyl)thio)phenoxy)acetamide ([11C]K2), a radiopharmaceutical for the glutamate α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid (AMPA) receptor, is reported. Although manual syntheses have been described, these are unsuitable for routine production of larger batches of [11C]K2 for (pre)clinical PET imaging applications. To meet demands for the imaging agent from our functional neuroimaging collaborators, herein, we report a current good manufacturing practice (cGMP)-compliant synthesis of [11C]K2 using a commercial synthesis module. The new synthesis is fully automated and has been validated for clinical use. The total synthesis time is 33 min from end of bombardment, and the production method provides 2.66 ± 0.3 GBq (71.9 ± 8.6 mCi) of [11C]K2 in 97.7 ± 0.5% radiochemical purity and 754.1 ± 231.5 TBq/mmol (20,382.7 ± 6256.1 Ci/mmol) molar activity (n = 3). Batches passed all requisite quality control testing confirming suitability for clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.30
自引率
0.00%
发文量
57
审稿时长
1 months
期刊介绍: The Journal of Labelled Compounds and Radiopharmaceuticals publishes all aspects of research dealing with labeled compound preparation and applications of these compounds. This includes tracer methods used in medical, pharmacological, biological, biochemical and chemical research in vitro and in vivo. The Journal of Labelled Compounds and Radiopharmaceuticals devotes particular attention to biomedical research, diagnostic and therapeutic applications of radiopharmaceuticals, covering all stages of development from basic metabolic research and technological development to preclinical and clinical studies based on physically and chemically well characterized molecular structures, coordination compounds and nano-particles.
期刊最新文献
Towards Optimal Automated 68Ga-Radiolabeling Conditions of the DOTA-Bisphosphonate BPAMD Without Pre-Purification of the Generator Eluate. Issue Information Simplified Flow Photosynthesis of Deuterium-Labeled Pyocyanin. A Brief Review of Radiolabelling Nucleic Acid-Based Molecules for Tracking and Monitoring Next Generation of Solid Target Radionuclide Antibody Conjugates for Tumor Immuno-Therapy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1