Ragnhild V Nome, Elisabeth Paus, Johanna E Gehin, Nils Bolstad, Trine Bjøro
{"title":"管理血清神经元特异性烯醇化酶测量中的溶血现象--一种用于常规实践的自动算法。","authors":"Ragnhild V Nome, Elisabeth Paus, Johanna E Gehin, Nils Bolstad, Trine Bjøro","doi":"10.1080/00365513.2024.2359091","DOIUrl":null,"url":null,"abstract":"<p><p>Neuron-specific enolase (NSE) derived from neurons and peripheral neuroendocrine cells is a biomarker for neuroendocrine tumors and for prognostication in comatose cardiac arrest survivors. However, as platelets and erythrocytes contain NSE, hemolysis causes falsely elevated NSE. We used native serum and hemolysate derived from the same patients to make serial dilutions, and subsequently measured NSE (mNSE) and hemolytic index (HI) in each dilution. An algorithm suitable for the laboratory information system was developed based on the mNSE, HI and the estimated gradient of hemolytic interference from 30 patients. We estimated the associated uncertainty of the corrected NSE (cNSE) results based on the observed range of the gradient and derived an equation for cNSE for samples with limited hemolysis (i.e. 5 < HI ≤ 30): cNSE = mNSE - HI × (0.34 ± 0.23) µg/L. By semi-quantitatively grading the contribution from limited hemolysis, a texted result noting the hemolysis-associated degree of uncertainty can accompany the cNSE result. The major challenge of hemolysis when using serum NSE as a biomarker can be managed using an automated algorithm for correction of NSE results based on degree of hemolysis. However, laboratorians and clinicians should be aware of the limitations associated with <i>in vivo</i> hemolysis.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"225-229"},"PeriodicalIF":1.3000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Managing hemolysis in serum neuron-specific enolase measurements - an automated algorithm for routine practice.\",\"authors\":\"Ragnhild V Nome, Elisabeth Paus, Johanna E Gehin, Nils Bolstad, Trine Bjøro\",\"doi\":\"10.1080/00365513.2024.2359091\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Neuron-specific enolase (NSE) derived from neurons and peripheral neuroendocrine cells is a biomarker for neuroendocrine tumors and for prognostication in comatose cardiac arrest survivors. However, as platelets and erythrocytes contain NSE, hemolysis causes falsely elevated NSE. We used native serum and hemolysate derived from the same patients to make serial dilutions, and subsequently measured NSE (mNSE) and hemolytic index (HI) in each dilution. An algorithm suitable for the laboratory information system was developed based on the mNSE, HI and the estimated gradient of hemolytic interference from 30 patients. We estimated the associated uncertainty of the corrected NSE (cNSE) results based on the observed range of the gradient and derived an equation for cNSE for samples with limited hemolysis (i.e. 5 < HI ≤ 30): cNSE = mNSE - HI × (0.34 ± 0.23) µg/L. By semi-quantitatively grading the contribution from limited hemolysis, a texted result noting the hemolysis-associated degree of uncertainty can accompany the cNSE result. The major challenge of hemolysis when using serum NSE as a biomarker can be managed using an automated algorithm for correction of NSE results based on degree of hemolysis. However, laboratorians and clinicians should be aware of the limitations associated with <i>in vivo</i> hemolysis.</p>\",\"PeriodicalId\":21474,\"journal\":{\"name\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"volume\":\" \",\"pages\":\"225-229\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00365513.2024.2359091\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2024.2359091","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/10 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
Managing hemolysis in serum neuron-specific enolase measurements - an automated algorithm for routine practice.
Neuron-specific enolase (NSE) derived from neurons and peripheral neuroendocrine cells is a biomarker for neuroendocrine tumors and for prognostication in comatose cardiac arrest survivors. However, as platelets and erythrocytes contain NSE, hemolysis causes falsely elevated NSE. We used native serum and hemolysate derived from the same patients to make serial dilutions, and subsequently measured NSE (mNSE) and hemolytic index (HI) in each dilution. An algorithm suitable for the laboratory information system was developed based on the mNSE, HI and the estimated gradient of hemolytic interference from 30 patients. We estimated the associated uncertainty of the corrected NSE (cNSE) results based on the observed range of the gradient and derived an equation for cNSE for samples with limited hemolysis (i.e. 5 < HI ≤ 30): cNSE = mNSE - HI × (0.34 ± 0.23) µg/L. By semi-quantitatively grading the contribution from limited hemolysis, a texted result noting the hemolysis-associated degree of uncertainty can accompany the cNSE result. The major challenge of hemolysis when using serum NSE as a biomarker can be managed using an automated algorithm for correction of NSE results based on degree of hemolysis. However, laboratorians and clinicians should be aware of the limitations associated with in vivo hemolysis.
期刊介绍:
The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry.
The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.