用薄膜微萃取法和激光诱导击穿光谱法评估木质素和浸渍涂层的元素分析效果

IF 3.2 2区 化学 Q1 SPECTROSCOPY Spectrochimica Acta Part B: Atomic Spectroscopy Pub Date : 2024-06-06 DOI:10.1016/j.sab.2024.106968
I. Gaubeur , A. Marco , M. Hidalgo
{"title":"用薄膜微萃取法和激光诱导击穿光谱法评估木质素和浸渍涂层的元素分析效果","authors":"I. Gaubeur ,&nbsp;A. Marco ,&nbsp;M. Hidalgo","doi":"10.1016/j.sab.2024.106968","DOIUrl":null,"url":null,"abstract":"<div><p>Separation and preconcentration procedures are often necessary to eliminate interferents, enhance sensitivity, and improve detection limits. Conventional solid-phase extraction (batch) finds extensive applications in the determination of various analytes, particularly in low concentrations and complex matrices such as environmental, food, and biological samples. However, drawbacks include high reagent consumption, time-consuming sample processing and low analytical throughput. To address these issues and promote Green Analytical Chemistry (GAC), novel methods have emerged, with solid-phase and liquid-phase microextraction being notable examples. Thin Film Microextraction (TFME) represents an innovative approach involving a solid support coated with a thin layer of adsorbent material, attached to a rod and immersed in the sample solution. Extracted analytes can be quantified either after desorption (elution) or directly on the thin film. This article aims to explore TFME's potential when combined with Laser-Induced Breakdown Spectroscopy (LIBS) for Cd, Cr and Ni determination using lignin as adsorbent material deposited on a solid substrate by dip coating. Under optimized conditions, limits of detection obtained were 1.76 μg kg<sup>−1</sup> (Cd), 5.72 μg kg<sup>−1</sup> (Cr), and 3.27 μg kg<sup>−1</sup> (Ni). The accuracy of the proposed method was evaluated through the analysis of a certified reference material (ERM® CA713), drinking and tap water.</p></div>","PeriodicalId":21890,"journal":{"name":"Spectrochimica Acta Part B: Atomic Spectroscopy","volume":"217 ","pages":"Article 106968"},"PeriodicalIF":3.2000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of lignin and dip coating for elemental analysis by thin film microextraction followed by laser-induced breakdown spectroscopy\",\"authors\":\"I. Gaubeur ,&nbsp;A. Marco ,&nbsp;M. Hidalgo\",\"doi\":\"10.1016/j.sab.2024.106968\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Separation and preconcentration procedures are often necessary to eliminate interferents, enhance sensitivity, and improve detection limits. Conventional solid-phase extraction (batch) finds extensive applications in the determination of various analytes, particularly in low concentrations and complex matrices such as environmental, food, and biological samples. However, drawbacks include high reagent consumption, time-consuming sample processing and low analytical throughput. To address these issues and promote Green Analytical Chemistry (GAC), novel methods have emerged, with solid-phase and liquid-phase microextraction being notable examples. Thin Film Microextraction (TFME) represents an innovative approach involving a solid support coated with a thin layer of adsorbent material, attached to a rod and immersed in the sample solution. Extracted analytes can be quantified either after desorption (elution) or directly on the thin film. This article aims to explore TFME's potential when combined with Laser-Induced Breakdown Spectroscopy (LIBS) for Cd, Cr and Ni determination using lignin as adsorbent material deposited on a solid substrate by dip coating. Under optimized conditions, limits of detection obtained were 1.76 μg kg<sup>−1</sup> (Cd), 5.72 μg kg<sup>−1</sup> (Cr), and 3.27 μg kg<sup>−1</sup> (Ni). The accuracy of the proposed method was evaluated through the analysis of a certified reference material (ERM® CA713), drinking and tap water.</p></div>\",\"PeriodicalId\":21890,\"journal\":{\"name\":\"Spectrochimica Acta Part B: Atomic Spectroscopy\",\"volume\":\"217 \",\"pages\":\"Article 106968\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spectrochimica Acta Part B: Atomic Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0584854724001125\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica Acta Part B: Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0584854724001125","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

摘要

为了消除干扰、提高灵敏度和检测限,通常需要进行分离和预浓缩程序。传统的固相萃取(批次萃取)广泛应用于各种分析物的测定,尤其是在低浓度和复杂基质(如环境、食品和生物样品)中。然而,其缺点包括试剂消耗量大、样品处理耗时和分析通量低。为了解决这些问题并促进绿色分析化学(GAC)的发展,出现了一些新方法,其中固相和液相微萃取法就是显著的例子。薄膜微萃取法(TFME)是一种创新方法,它将涂有一薄层吸附材料的固体支撑物固定在一根杆上,然后浸入样品溶液中。提取的分析物可以在解吸(洗脱)后或直接在薄膜上定量。本文旨在探讨 TFME 与激光诱导击穿光谱法(LIBS)结合使用的潜力,即使用木质素作为吸附材料,通过浸涂沉积在固体基底上,测定镉、铬和镍。在优化条件下,检测限分别为 1.76 μg kg-1(镉)、5.72 μg kg-1(铬)和 3.27 μg kg-1(镍)。通过对有证标准物质(ERM® CA713)、饮用水和自来水的分析,评估了该方法的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of lignin and dip coating for elemental analysis by thin film microextraction followed by laser-induced breakdown spectroscopy

Separation and preconcentration procedures are often necessary to eliminate interferents, enhance sensitivity, and improve detection limits. Conventional solid-phase extraction (batch) finds extensive applications in the determination of various analytes, particularly in low concentrations and complex matrices such as environmental, food, and biological samples. However, drawbacks include high reagent consumption, time-consuming sample processing and low analytical throughput. To address these issues and promote Green Analytical Chemistry (GAC), novel methods have emerged, with solid-phase and liquid-phase microextraction being notable examples. Thin Film Microextraction (TFME) represents an innovative approach involving a solid support coated with a thin layer of adsorbent material, attached to a rod and immersed in the sample solution. Extracted analytes can be quantified either after desorption (elution) or directly on the thin film. This article aims to explore TFME's potential when combined with Laser-Induced Breakdown Spectroscopy (LIBS) for Cd, Cr and Ni determination using lignin as adsorbent material deposited on a solid substrate by dip coating. Under optimized conditions, limits of detection obtained were 1.76 μg kg−1 (Cd), 5.72 μg kg−1 (Cr), and 3.27 μg kg−1 (Ni). The accuracy of the proposed method was evaluated through the analysis of a certified reference material (ERM® CA713), drinking and tap water.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
12.10%
发文量
173
审稿时长
81 days
期刊介绍: Spectrochimica Acta Part B: Atomic Spectroscopy, is intended for the rapid publication of both original work and reviews in the following fields: Atomic Emission (AES), Atomic Absorption (AAS) and Atomic Fluorescence (AFS) spectroscopy; Mass Spectrometry (MS) for inorganic analysis covering Spark Source (SS-MS), Inductively Coupled Plasma (ICP-MS), Glow Discharge (GD-MS), and Secondary Ion Mass Spectrometry (SIMS). Laser induced atomic spectroscopy for inorganic analysis, including non-linear optical laser spectroscopy, covering Laser Enhanced Ionization (LEI), Laser Induced Fluorescence (LIF), Resonance Ionization Spectroscopy (RIS) and Resonance Ionization Mass Spectrometry (RIMS); Laser Induced Breakdown Spectroscopy (LIBS); Cavity Ringdown Spectroscopy (CRDS), Laser Ablation Inductively Coupled Plasma Atomic Emission Spectroscopy (LA-ICP-AES) and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). X-ray spectrometry, X-ray Optics and Microanalysis, including X-ray fluorescence spectrometry (XRF) and related techniques, in particular Total-reflection X-ray Fluorescence Spectrometry (TXRF), and Synchrotron Radiation-excited Total reflection XRF (SR-TXRF). Manuscripts dealing with (i) fundamentals, (ii) methodology development, (iii)instrumentation, and (iv) applications, can be submitted for publication.
期刊最新文献
Assessment of acupuncture's effectiveness in treating gulf war illness using laser induced breakdown spectroscopy and inductively coupled plasma mass spectrometry Characterization of the distribution of mineral elements in chromium-stressed rice (Oryza sativa L.) leaves based on laser-induced breakdown spectroscopy and data augmentation Rapid determination of 90Sr in seawater using a novel porous crown-based resin and tandem quadrupole ICP-MS/MS in cool plasma and O2-He mode Consideration of spectral interference in total reflection X-ray fluorescence analysis using a limited number of calibration samples: Case study of ocean polymetallic nodules Signal enhancement with double-pulse LIBS on biological samples and better discrimination of tissues through machine learning algorithms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1