用于检测隐球菌抗原的夹心化学发光磁性微粒免疫分析法。

IF 3.9 3区 医学 Q1 PATHOLOGY Expert Review of Molecular Diagnostics Pub Date : 2024-06-01 Epub Date: 2024-06-19 DOI:10.1080/14737159.2024.2369243
Junpu Li, Yan Guo
{"title":"用于检测隐球菌抗原的夹心化学发光磁性微粒免疫分析法。","authors":"Junpu Li, Yan Guo","doi":"10.1080/14737159.2024.2369243","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cryptococcosis is a global invasive mycosis associated with significant morbidity and mortality. Cryptococcal antigen (CrAg) testing from serum and cerebrospinal fluid (CSF) has been regarded as a gold standard for early diagnosis. This study aimed to develop and validate a rapid and sensitive sandwich chemiluminescent magnetic microparticle immunoassay (CMIA) for quantitative detection of CrAg in sera.</p><p><strong>Research design and methods: </strong>CMIA is based on magnetic beads modified with capture antibodies and biotinylated antibodies and Streptavidin-polyHRP, where biotinylated antibodies functioned as the recognition element and Streptavidin-polyHRP as the signal component. Assay parameters were first optimized, and then assay performances were evaluated.</p><p><strong>Results: </strong>Under optimized conditions, the total runtime of the CMIA was 22 min. The assay had a wide linear range (2 -10,000 ng/mL) and high analytical sensitivity (0.24 ng/mL), together with acceptable reproducibility, accuracy, and stability. Besides, it exhibited no cross-reactivity with other pathogens. Importantly, the assay showed 92.91% (95% CI, 80.97-93.02%) overall qualitative agreement with a commercial ELISA kit in a retrospective cohort of 55 cases with confirmed cryptococcal infection, and 72 controls without evidence of invasive fungal disease (IFD).</p><p><strong>Conclusion: </strong>These results demonstrated that the present study paved a novel strategy for reliable quantitative detection of CrAg in sera.</p>","PeriodicalId":12113,"journal":{"name":"Expert Review of Molecular Diagnostics","volume":" ","pages":"533-540"},"PeriodicalIF":3.9000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A sandwich chemiluminescent magnetic microparticle immunoassay for cryptococcal antigen detection.\",\"authors\":\"Junpu Li, Yan Guo\",\"doi\":\"10.1080/14737159.2024.2369243\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Cryptococcosis is a global invasive mycosis associated with significant morbidity and mortality. Cryptococcal antigen (CrAg) testing from serum and cerebrospinal fluid (CSF) has been regarded as a gold standard for early diagnosis. This study aimed to develop and validate a rapid and sensitive sandwich chemiluminescent magnetic microparticle immunoassay (CMIA) for quantitative detection of CrAg in sera.</p><p><strong>Research design and methods: </strong>CMIA is based on magnetic beads modified with capture antibodies and biotinylated antibodies and Streptavidin-polyHRP, where biotinylated antibodies functioned as the recognition element and Streptavidin-polyHRP as the signal component. Assay parameters were first optimized, and then assay performances were evaluated.</p><p><strong>Results: </strong>Under optimized conditions, the total runtime of the CMIA was 22 min. The assay had a wide linear range (2 -10,000 ng/mL) and high analytical sensitivity (0.24 ng/mL), together with acceptable reproducibility, accuracy, and stability. Besides, it exhibited no cross-reactivity with other pathogens. Importantly, the assay showed 92.91% (95% CI, 80.97-93.02%) overall qualitative agreement with a commercial ELISA kit in a retrospective cohort of 55 cases with confirmed cryptococcal infection, and 72 controls without evidence of invasive fungal disease (IFD).</p><p><strong>Conclusion: </strong>These results demonstrated that the present study paved a novel strategy for reliable quantitative detection of CrAg in sera.</p>\",\"PeriodicalId\":12113,\"journal\":{\"name\":\"Expert Review of Molecular Diagnostics\",\"volume\":\" \",\"pages\":\"533-540\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Expert Review of Molecular Diagnostics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/14737159.2024.2369243\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert Review of Molecular Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14737159.2024.2369243","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:隐球菌病是一种全球性侵袭性真菌病,发病率和死亡率都很高。从血清和脑脊液(CSF)中检测隐球菌抗原(CrAg)一直被视为早期诊断的金标准。本研究旨在开发和验证一种快速、灵敏的夹心化学发光磁性微粒免疫分析法(CMIA),用于定量检测血清中的 CrAg:夹心化学发光磁性微粒免疫分析法是基于捕获抗体和生物素化抗体修饰的磁珠以及聚磷酸链霉亲和素,其中生物素化抗体作为识别元件,聚磷酸链霉亲和素作为信号元件。首先对测定参数进行了优化,然后对测定性能进行了评估:结果:在优化条件下,CMIA 的总运行时间为 22 分钟。该测定的线性范围宽(2 -10,000 ng/mL),分析灵敏度高(0.24 ng/mL),重现性、准确性和稳定性均可接受。此外,它与其他病原体没有交叉反应。重要的是,在55例确诊隐球菌感染病例和72例无侵袭性真菌病(IFD)证据的对照组的回顾性队列中,该检测方法与商业ELISA试剂盒的总体定性一致率为92.91%(95% CI,80.97-93.02%):这些结果表明,本研究为血清中 CrAg 的可靠定量检测提供了一种新策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A sandwich chemiluminescent magnetic microparticle immunoassay for cryptococcal antigen detection.

Background: Cryptococcosis is a global invasive mycosis associated with significant morbidity and mortality. Cryptococcal antigen (CrAg) testing from serum and cerebrospinal fluid (CSF) has been regarded as a gold standard for early diagnosis. This study aimed to develop and validate a rapid and sensitive sandwich chemiluminescent magnetic microparticle immunoassay (CMIA) for quantitative detection of CrAg in sera.

Research design and methods: CMIA is based on magnetic beads modified with capture antibodies and biotinylated antibodies and Streptavidin-polyHRP, where biotinylated antibodies functioned as the recognition element and Streptavidin-polyHRP as the signal component. Assay parameters were first optimized, and then assay performances were evaluated.

Results: Under optimized conditions, the total runtime of the CMIA was 22 min. The assay had a wide linear range (2 -10,000 ng/mL) and high analytical sensitivity (0.24 ng/mL), together with acceptable reproducibility, accuracy, and stability. Besides, it exhibited no cross-reactivity with other pathogens. Importantly, the assay showed 92.91% (95% CI, 80.97-93.02%) overall qualitative agreement with a commercial ELISA kit in a retrospective cohort of 55 cases with confirmed cryptococcal infection, and 72 controls without evidence of invasive fungal disease (IFD).

Conclusion: These results demonstrated that the present study paved a novel strategy for reliable quantitative detection of CrAg in sera.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.60
自引率
0.00%
发文量
71
审稿时长
1 months
期刊介绍: Expert Review of Molecular Diagnostics (ISSN 1473-7159) publishes expert reviews of the latest advancements in the field of molecular diagnostics including the detection and monitoring of the molecular causes of disease that are being translated into groundbreaking diagnostic and prognostic technologies to be used in the clinical diagnostic setting. Each issue of Expert Review of Molecular Diagnostics contains leading reviews on current and emerging topics relating to molecular diagnostics, subject to a rigorous peer review process; editorials discussing contentious issues in the field; diagnostic profiles featuring independent, expert evaluations of diagnostic tests; meeting reports of recent molecular diagnostics conferences and key paper evaluations featuring assessments of significant, recently published articles from specialists in molecular diagnostic therapy. Expert Review of Molecular Diagnostics provides the forum for reporting the critical advances being made in this ever-expanding field, as well as the major challenges ahead in their clinical implementation. The journal delivers this information in concise, at-a-glance article formats: invaluable to a time-constrained community.
期刊最新文献
Promising biomarkers of Kawasaki disease: markers that aid in diagnosis. Strengths and limitations of molecular diagnostics for Pneumocystis jirovecii pneumonia. Genetic-based diagnostics of Parkinson's disease and other Parkinsonian syndromes. Biomarkers of treatment response in bladder cancer. Lipid-associated GWAS loci as important markers of the risk, severity, and clinical course of peripheral artery disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1