{"title":"[心血管植入式电子设备术后随访中远程编程的可行性和安全性]。","authors":"Y Long, L Tong, S J Qin, J Li, S Q Xiong, L Cai","doi":"10.3760/cma.j.cn112148-20231007-00222","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To explore the feasibility and safety of remote programming technology based on 5G cloud technology support platform in postoperative follow-up of cardiovascular implantable electronic devices(CIED). <b>Methods:</b> This study was a multicenter cross-sectional study. CIED patients from 12 hospitals lacking full-time follow-up specialists in Sichuan Province were enrolled from June 2021 to October 2021. All patients' devices received remote inspecting and programming by the follow-up specialist of the remote follow-up center of the Third People's Hospital of Chengdu through 5G cloud technology support platform. The baseline data, device alarm events, device reprogramming events, adverse reactions and satisfaction questionnaire survey results were collected. <b>Results:</b> A total of 195 CIED implantation patients were included, with an age of (72.5±11.3) years, including 103 males (52.6%). All patients completed remote inspecting and programming successfully, with a duration of (5.8±4.0) min. Ninety-one patients' CIED were reprogrammed, with a total of 104 parameter adjustments. No abnormal communication or adverse events occurred. The satisfaction questionnaire showed that 97.9%(191/195) of the patients trusted or relatively trusted remote follow-up and 86.7%(169/195) of the patients were willing to choose remote follow-up mode for device management. <b>Conclusion:</b> The remote programming based on 5G cloud technology support platform may be feasible and safe for postoperative follow-up of CIED patients.</p>","PeriodicalId":38755,"journal":{"name":"中华心血管病杂志","volume":"52 6","pages":"684-689"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Feasibility and safety of remote programming in postoperative follow-up of cardiovascular implantable electronic devices].\",\"authors\":\"Y Long, L Tong, S J Qin, J Li, S Q Xiong, L Cai\",\"doi\":\"10.3760/cma.j.cn112148-20231007-00222\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To explore the feasibility and safety of remote programming technology based on 5G cloud technology support platform in postoperative follow-up of cardiovascular implantable electronic devices(CIED). <b>Methods:</b> This study was a multicenter cross-sectional study. CIED patients from 12 hospitals lacking full-time follow-up specialists in Sichuan Province were enrolled from June 2021 to October 2021. All patients' devices received remote inspecting and programming by the follow-up specialist of the remote follow-up center of the Third People's Hospital of Chengdu through 5G cloud technology support platform. The baseline data, device alarm events, device reprogramming events, adverse reactions and satisfaction questionnaire survey results were collected. <b>Results:</b> A total of 195 CIED implantation patients were included, with an age of (72.5±11.3) years, including 103 males (52.6%). All patients completed remote inspecting and programming successfully, with a duration of (5.8±4.0) min. Ninety-one patients' CIED were reprogrammed, with a total of 104 parameter adjustments. No abnormal communication or adverse events occurred. The satisfaction questionnaire showed that 97.9%(191/195) of the patients trusted or relatively trusted remote follow-up and 86.7%(169/195) of the patients were willing to choose remote follow-up mode for device management. <b>Conclusion:</b> The remote programming based on 5G cloud technology support platform may be feasible and safe for postoperative follow-up of CIED patients.</p>\",\"PeriodicalId\":38755,\"journal\":{\"name\":\"中华心血管病杂志\",\"volume\":\"52 6\",\"pages\":\"684-689\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华心血管病杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn112148-20231007-00222\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华心血管病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112148-20231007-00222","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
[Feasibility and safety of remote programming in postoperative follow-up of cardiovascular implantable electronic devices].
Objective: To explore the feasibility and safety of remote programming technology based on 5G cloud technology support platform in postoperative follow-up of cardiovascular implantable electronic devices(CIED). Methods: This study was a multicenter cross-sectional study. CIED patients from 12 hospitals lacking full-time follow-up specialists in Sichuan Province were enrolled from June 2021 to October 2021. All patients' devices received remote inspecting and programming by the follow-up specialist of the remote follow-up center of the Third People's Hospital of Chengdu through 5G cloud technology support platform. The baseline data, device alarm events, device reprogramming events, adverse reactions and satisfaction questionnaire survey results were collected. Results: A total of 195 CIED implantation patients were included, with an age of (72.5±11.3) years, including 103 males (52.6%). All patients completed remote inspecting and programming successfully, with a duration of (5.8±4.0) min. Ninety-one patients' CIED were reprogrammed, with a total of 104 parameter adjustments. No abnormal communication or adverse events occurred. The satisfaction questionnaire showed that 97.9%(191/195) of the patients trusted or relatively trusted remote follow-up and 86.7%(169/195) of the patients were willing to choose remote follow-up mode for device management. Conclusion: The remote programming based on 5G cloud technology support platform may be feasible and safe for postoperative follow-up of CIED patients.
中华心血管病杂志Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.40
自引率
0.00%
发文量
10577
期刊介绍:
The Chinese Journal of Cardiology , established in February 1973, is one of the major academic medical journals sponsored by the Chinese Medical Association and a leading periodical in the field of cardiology in China. It specializes in cardiology and related disciplines with a readership of more than 25 000. The journal publishes editorials and guidelines as well as important original articles on clinical and experimental investigations, reflecting achievements made in China and promoting academic communication between domestic and foreign cardiologists. The journal includes the following columns: Editorials, Strategies, Comments, Clinical Investigations, Experimental Investigations, Epidemiology and Prevention, Lectures, Comprehensive Reviews, Continuing Medical Education, etc.