对在中波红外范围内工作的带有冷却探测器的热成像仪的选定校准方法进行比较分析

Karol Erd
{"title":"对在中波红外范围内工作的带有冷却探测器的热成像仪的选定校准方法进行比较分析","authors":"Karol Erd","doi":"10.14313/par_252/45","DOIUrl":null,"url":null,"abstract":"For accurate remote temperature measurement with a thermal imaging camera, it is necessary to perform radiometric calibration. This allows the radiative parameters of an object, and therefore its temperature, to be related to the response of the infrared detector observing it. The article presents the basic concepts related to radiometric calibration and various factors influencing its effectiveness. The most common calibration methods were also reviewed, and then two of them were implemented and compared on a specially constructed laboratory station, using proprietary software and equipped with a cooled infrared camera, operating in the MWIR range. The camera was calibrated in the temperature range from 20 °C to 50 ° C. The comparison of methods was carried out on the basis of a series of temperature measurements, analysis of absolute and relative errors, as well as analysis of the dispersion of the measured temperature values.","PeriodicalId":383231,"journal":{"name":"Pomiary Automatyka Robotyka","volume":"38 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Analysis of Selected Calibration Methods for a Thermal Imaging Camera with a Cooled Detector Operating in the MWIR Range\",\"authors\":\"Karol Erd\",\"doi\":\"10.14313/par_252/45\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For accurate remote temperature measurement with a thermal imaging camera, it is necessary to perform radiometric calibration. This allows the radiative parameters of an object, and therefore its temperature, to be related to the response of the infrared detector observing it. The article presents the basic concepts related to radiometric calibration and various factors influencing its effectiveness. The most common calibration methods were also reviewed, and then two of them were implemented and compared on a specially constructed laboratory station, using proprietary software and equipped with a cooled infrared camera, operating in the MWIR range. The camera was calibrated in the temperature range from 20 °C to 50 ° C. The comparison of methods was carried out on the basis of a series of temperature measurements, analysis of absolute and relative errors, as well as analysis of the dispersion of the measured temperature values.\",\"PeriodicalId\":383231,\"journal\":{\"name\":\"Pomiary Automatyka Robotyka\",\"volume\":\"38 12\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pomiary Automatyka Robotyka\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14313/par_252/45\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pomiary Automatyka Robotyka","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14313/par_252/45","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

要使用热像仪进行精确的远程温度测量,必须进行辐射校准。这样就可以将物体的辐射参数及其温度与观测物体的红外探测器的响应联系起来。文章介绍了与辐射校准有关的基本概念以及影响其有效性的各种因素。文章还回顾了最常用的校准方法,然后在一个专门建造的实验室台站上对其中两种方法进行了实施和比较,该台站使用专有软件,配备了一台在中波红外范围内工作的冷却红外热像仪。在一系列温度测量、绝对误差和相对误差分析以及温度测量值分散性分析的基础上,对各种方法进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparative Analysis of Selected Calibration Methods for a Thermal Imaging Camera with a Cooled Detector Operating in the MWIR Range
For accurate remote temperature measurement with a thermal imaging camera, it is necessary to perform radiometric calibration. This allows the radiative parameters of an object, and therefore its temperature, to be related to the response of the infrared detector observing it. The article presents the basic concepts related to radiometric calibration and various factors influencing its effectiveness. The most common calibration methods were also reviewed, and then two of them were implemented and compared on a specially constructed laboratory station, using proprietary software and equipped with a cooled infrared camera, operating in the MWIR range. The camera was calibrated in the temperature range from 20 °C to 50 ° C. The comparison of methods was carried out on the basis of a series of temperature measurements, analysis of absolute and relative errors, as well as analysis of the dispersion of the measured temperature values.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparative Analysis of Selected Calibration Methods for a Thermal Imaging Camera with a Cooled Detector Operating in the MWIR Range A Method of Measurement of Minimum Resolvable Temperature Difference as a Function of Magnification and Defocusing of a Thermal Camera Study on the Influence of an UGV Suspension System on Camera Motion of the Teleoperation System Tuning the Heading Controller for the Ship’s Autopilot Generation of Spatial Terrain Using the Hermes Editor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1