老一代(MEL 60)和新一代(SCHWIND AMARIS)准分子屈光激光治疗效果比较

M. Dió, Sz. Molnár, Cs. Szekrényesi, B. Halmai, J. Takács, Z.Z. Nagy
{"title":"老一代(MEL 60)和新一代(SCHWIND AMARIS)准分子屈光激光治疗效果比较","authors":"M. Dió, Sz. Molnár, Cs. Szekrényesi, B. Halmai, J. Takács, Z.Z. Nagy","doi":"10.1556/2066.2024.00063","DOIUrl":null,"url":null,"abstract":"The present study compares the efficacy of refractive surgery using third-generation and sixth-generation laser vision correction procedures in terms of postoperative visual acuity. The goal of the authors was to determine whether advances in laser technology had improved patients' uncorrected visual acuity, as measured at six-month follow-ups.Results were reported from one of Europe's leading laser eye clinics, which has performed an outstandingly high number of treatments (over 100,000). The results of the clinic's first 10,000 treatments and most recent 10,000 treatments were evaluated.The analysis was performed by treated dioptric range and age group. The raw six-month visual acuity results show a statistically significant improvement over the last 10,000 interventions. The treatments resulted in significant improvements in all groups compared to the previous technology. With the new devices, visual acuity increased to above 1.0 in young myopes. The best results were seen in patients between 18 and 45 years of age, in the dioptric range between −1.0 D and −6.0 D.It can be concluded that advances in technology improved refractive outcomes in all patient groups. This conclusion has excellent reliability and predictability due to the particularly high number of cases.","PeriodicalId":52607,"journal":{"name":"Developments in Health Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison of the results of old-generation (MEL 60) and new-generation (SCHWIND AMARIS) refractive excimer laser treatments\",\"authors\":\"M. Dió, Sz. Molnár, Cs. Szekrényesi, B. Halmai, J. Takács, Z.Z. Nagy\",\"doi\":\"10.1556/2066.2024.00063\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present study compares the efficacy of refractive surgery using third-generation and sixth-generation laser vision correction procedures in terms of postoperative visual acuity. The goal of the authors was to determine whether advances in laser technology had improved patients' uncorrected visual acuity, as measured at six-month follow-ups.Results were reported from one of Europe's leading laser eye clinics, which has performed an outstandingly high number of treatments (over 100,000). The results of the clinic's first 10,000 treatments and most recent 10,000 treatments were evaluated.The analysis was performed by treated dioptric range and age group. The raw six-month visual acuity results show a statistically significant improvement over the last 10,000 interventions. The treatments resulted in significant improvements in all groups compared to the previous technology. With the new devices, visual acuity increased to above 1.0 in young myopes. The best results were seen in patients between 18 and 45 years of age, in the dioptric range between −1.0 D and −6.0 D.It can be concluded that advances in technology improved refractive outcomes in all patient groups. This conclusion has excellent reliability and predictability due to the particularly high number of cases.\",\"PeriodicalId\":52607,\"journal\":{\"name\":\"Developments in Health Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Developments in Health Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1556/2066.2024.00063\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Developments in Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/2066.2024.00063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究比较了使用第三代和第六代激光视力矫正手术的屈光手术在术后视力方面的疗效。作者的目标是确定激光技术的进步是否提高了患者的未矫正视力,并在6个月的随访中进行测量。对该诊所前 10,000 次治疗和最近 10,000 次治疗的结果进行了评估。六个月的原始视力结果显示,在过去的 10,000 次干预中,视力有了统计学意义上的显著提高。与以前的技术相比,所有组别的治疗效果都有明显改善。使用新设备后,年轻近视患者的视力提高到了 1.0 以上。可以说,技术的进步改善了所有患者群体的屈光疗效。由于病例数量特别多,这一结论具有极高的可靠性和可预测性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A comparison of the results of old-generation (MEL 60) and new-generation (SCHWIND AMARIS) refractive excimer laser treatments
The present study compares the efficacy of refractive surgery using third-generation and sixth-generation laser vision correction procedures in terms of postoperative visual acuity. The goal of the authors was to determine whether advances in laser technology had improved patients' uncorrected visual acuity, as measured at six-month follow-ups.Results were reported from one of Europe's leading laser eye clinics, which has performed an outstandingly high number of treatments (over 100,000). The results of the clinic's first 10,000 treatments and most recent 10,000 treatments were evaluated.The analysis was performed by treated dioptric range and age group. The raw six-month visual acuity results show a statistically significant improvement over the last 10,000 interventions. The treatments resulted in significant improvements in all groups compared to the previous technology. With the new devices, visual acuity increased to above 1.0 in young myopes. The best results were seen in patients between 18 and 45 years of age, in the dioptric range between −1.0 D and −6.0 D.It can be concluded that advances in technology improved refractive outcomes in all patient groups. This conclusion has excellent reliability and predictability due to the particularly high number of cases.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
15
审稿时长
34 weeks
期刊最新文献
Assessment of the knowledge and attitudes of nurses and social caregivers in relation to falls among elderly patients in healthcare settings in a Hungarian county A comparison of the results of old-generation (MEL 60) and new-generation (SCHWIND AMARIS) refractive excimer laser treatments Should academics be concerned about articles written by ChatGPT? Investigation of the effectiveness of a complex injury prevention programme among young swimmers National eye health data from the Hungary's Comprehensive Health Protection Screening Program 2010–2020–2030 (MÁESZ)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1