Guangjiang Li , Blake Dastrup , Ravi Shankar Palani , Michael A. Shapiro , Sudheer K. Jawla , Robert G. Griffin , Keith A. Nelson , Richard J. Temkin
{"title":"设计和优化氧化锆 MAS 转子中的太赫兹耦合,用于动态核偏振 NMR","authors":"Guangjiang Li , Blake Dastrup , Ravi Shankar Palani , Michael A. Shapiro , Sudheer K. Jawla , Robert G. Griffin , Keith A. Nelson , Richard J. Temkin","doi":"10.1016/j.jmr.2024.107722","DOIUrl":null,"url":null,"abstract":"<div><p>We present 3D electromagnetic simulations of the coupling of a 250 GHz beam to the sample in a 380 MHz DNP NMR spectrometer. To obtain accurate results for magic angle spinning (MAS) geometries, we first measured the complex dielectric constants of zirconia, sapphire, and the sample matrix material (DNP juice) from room temperature down to cryogenic temperatures and from 220 to 325 GHz with a VNA and up to 1 THz with a THz TDS system. Simulations of the coupling to the sample were carried out with the ANSYS HFSS code as a function of the rotor wall material (zirconia or sapphire), the rotor wall thickness, and the THz beam focusing (lens or no lens). For a zirconia rotor, the <em>B<sub>1</sub></em> field in the sample was found to be strongly dependent on the rotor wall thickness, which is attributed to the high refractive index of zirconia. The optimum thickness of the wall is likely due to a transmission maximum but is offset from the thickness predicted by a simple calculation for a flat slab of the wall material. The <em>B<sub>1</sub></em> value was found to be larger for a sapphire rotor than for a zirconia rotor for all cases studied. The results found in this work provide new insights into the coupling of THz radiation to the sample and should lead to improved designs of future DNP NMR instrumentation.</p></div>","PeriodicalId":16267,"journal":{"name":"Journal of magnetic resonance","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S109078072400106X/pdfft?md5=db8b4347b8201c62a1b0d4f9ecebf092&pid=1-s2.0-S109078072400106X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Design and optimization of THz coupling in zirconia MAS rotors for dynamic nuclear polarization NMR\",\"authors\":\"Guangjiang Li , Blake Dastrup , Ravi Shankar Palani , Michael A. Shapiro , Sudheer K. Jawla , Robert G. Griffin , Keith A. Nelson , Richard J. Temkin\",\"doi\":\"10.1016/j.jmr.2024.107722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>We present 3D electromagnetic simulations of the coupling of a 250 GHz beam to the sample in a 380 MHz DNP NMR spectrometer. To obtain accurate results for magic angle spinning (MAS) geometries, we first measured the complex dielectric constants of zirconia, sapphire, and the sample matrix material (DNP juice) from room temperature down to cryogenic temperatures and from 220 to 325 GHz with a VNA and up to 1 THz with a THz TDS system. Simulations of the coupling to the sample were carried out with the ANSYS HFSS code as a function of the rotor wall material (zirconia or sapphire), the rotor wall thickness, and the THz beam focusing (lens or no lens). For a zirconia rotor, the <em>B<sub>1</sub></em> field in the sample was found to be strongly dependent on the rotor wall thickness, which is attributed to the high refractive index of zirconia. The optimum thickness of the wall is likely due to a transmission maximum but is offset from the thickness predicted by a simple calculation for a flat slab of the wall material. The <em>B<sub>1</sub></em> value was found to be larger for a sapphire rotor than for a zirconia rotor for all cases studied. The results found in this work provide new insights into the coupling of THz radiation to the sample and should lead to improved designs of future DNP NMR instrumentation.</p></div>\",\"PeriodicalId\":16267,\"journal\":{\"name\":\"Journal of magnetic resonance\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S109078072400106X/pdfft?md5=db8b4347b8201c62a1b0d4f9ecebf092&pid=1-s2.0-S109078072400106X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of magnetic resonance\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S109078072400106X\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of magnetic resonance","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S109078072400106X","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Design and optimization of THz coupling in zirconia MAS rotors for dynamic nuclear polarization NMR
We present 3D electromagnetic simulations of the coupling of a 250 GHz beam to the sample in a 380 MHz DNP NMR spectrometer. To obtain accurate results for magic angle spinning (MAS) geometries, we first measured the complex dielectric constants of zirconia, sapphire, and the sample matrix material (DNP juice) from room temperature down to cryogenic temperatures and from 220 to 325 GHz with a VNA and up to 1 THz with a THz TDS system. Simulations of the coupling to the sample were carried out with the ANSYS HFSS code as a function of the rotor wall material (zirconia or sapphire), the rotor wall thickness, and the THz beam focusing (lens or no lens). For a zirconia rotor, the B1 field in the sample was found to be strongly dependent on the rotor wall thickness, which is attributed to the high refractive index of zirconia. The optimum thickness of the wall is likely due to a transmission maximum but is offset from the thickness predicted by a simple calculation for a flat slab of the wall material. The B1 value was found to be larger for a sapphire rotor than for a zirconia rotor for all cases studied. The results found in this work provide new insights into the coupling of THz radiation to the sample and should lead to improved designs of future DNP NMR instrumentation.
期刊介绍:
The Journal of Magnetic Resonance presents original technical and scientific papers in all aspects of magnetic resonance, including nuclear magnetic resonance spectroscopy (NMR) of solids and liquids, electron spin/paramagnetic resonance (EPR), in vivo magnetic resonance imaging (MRI) and spectroscopy (MRS), nuclear quadrupole resonance (NQR) and magnetic resonance phenomena at nearly zero fields or in combination with optics. The Journal''s main aims include deepening the physical principles underlying all these spectroscopies, publishing significant theoretical and experimental results leading to spectral and spatial progress in these areas, and opening new MR-based applications in chemistry, biology and medicine. The Journal also seeks descriptions of novel apparatuses, new experimental protocols, and new procedures of data analysis and interpretation - including computational and quantum-mechanical methods - capable of advancing MR spectroscopy and imaging.