用竞争性免疫测定法开发尿液中可替宁(COT)的护理点检测。

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analytical Methods Pub Date : 2024-06-20 DOI:10.1039/D4AY00518J
Suthinee Konziw, Paweena Tunakhun, Sawinee Ngernpimai, Oranee Srichaiyapol, Patcharee Boonsiri, Patcharaporn Tippayawat, Anchalee Techasen, Pornsuda Maraming, Kiattawee Choowongkomon, Sakda Daduang, Limthong Promdee and Jureerut Daduang
{"title":"用竞争性免疫测定法开发尿液中可替宁(COT)的护理点检测。","authors":"Suthinee Konziw, Paweena Tunakhun, Sawinee Ngernpimai, Oranee Srichaiyapol, Patcharee Boonsiri, Patcharaporn Tippayawat, Anchalee Techasen, Pornsuda Maraming, Kiattawee Choowongkomon, Sakda Daduang, Limthong Promdee and Jureerut Daduang","doi":"10.1039/D4AY00518J","DOIUrl":null,"url":null,"abstract":"<p >We present a sensitive and selective lateral flow immunoassay (LFIA) for cotinine (COT), the primary metabolite of nicotine. COT is widely recognized as a superior biomarker to evaluate tobacco smoke exposure. The LFIA uses a competitive assay format where the COT–BSA capture competes with the target COT in urine samples for binding to the monoclonal antibody against COT (mAb–COT) conjugated with gold nanoparticles (mAb–COT–AuNPs). To improve the sensitivity and selectivity of the LFIA-COT, we focused on optimizing the diameter of AuNPs, the conjugation of mAb–COT, and the concentration of the COT–BSA capture. Our findings reveal that the utilization of 40 nm AuNPs in conjugation with a concentration of 4 mg mL<small><sup>−1</sup></small> of mAb–COT demonstrated significantly greater efficacy compared to LFAs utilizing 20 nm AuNPs. Under the optimal conditions, the LFIA-COT demonstrated sensitive detection of COT at a level of 150 ng mL<small><sup>−1</sup></small> within 15 min, as observed by the naked eye. It possesses a linear range of 25 to 200 ng mL<small><sup>−1</sup></small> of COT, with the limit of detection (LOD) of 11.94 ng mL<small><sup>−1</sup></small> in human urine samples when the color intensity is analyzed using ImageJ software. Our LFIA described here is simple and requires less time for COT detection. It can be used for the rapid and quantitative detection of COT in urine samples in clinical settings.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development in competitive immunoassay of a point-of-care testing for cotinine (COT) detection in urine†\",\"authors\":\"Suthinee Konziw, Paweena Tunakhun, Sawinee Ngernpimai, Oranee Srichaiyapol, Patcharee Boonsiri, Patcharaporn Tippayawat, Anchalee Techasen, Pornsuda Maraming, Kiattawee Choowongkomon, Sakda Daduang, Limthong Promdee and Jureerut Daduang\",\"doi\":\"10.1039/D4AY00518J\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >We present a sensitive and selective lateral flow immunoassay (LFIA) for cotinine (COT), the primary metabolite of nicotine. COT is widely recognized as a superior biomarker to evaluate tobacco smoke exposure. The LFIA uses a competitive assay format where the COT–BSA capture competes with the target COT in urine samples for binding to the monoclonal antibody against COT (mAb–COT) conjugated with gold nanoparticles (mAb–COT–AuNPs). To improve the sensitivity and selectivity of the LFIA-COT, we focused on optimizing the diameter of AuNPs, the conjugation of mAb–COT, and the concentration of the COT–BSA capture. Our findings reveal that the utilization of 40 nm AuNPs in conjugation with a concentration of 4 mg mL<small><sup>−1</sup></small> of mAb–COT demonstrated significantly greater efficacy compared to LFAs utilizing 20 nm AuNPs. Under the optimal conditions, the LFIA-COT demonstrated sensitive detection of COT at a level of 150 ng mL<small><sup>−1</sup></small> within 15 min, as observed by the naked eye. It possesses a linear range of 25 to 200 ng mL<small><sup>−1</sup></small> of COT, with the limit of detection (LOD) of 11.94 ng mL<small><sup>−1</sup></small> in human urine samples when the color intensity is analyzed using ImageJ software. Our LFIA described here is simple and requires less time for COT detection. It can be used for the rapid and quantitative detection of COT in urine samples in clinical settings.</p>\",\"PeriodicalId\":64,\"journal\":{\"name\":\"Analytical Methods\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00518j\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ay/d4ay00518j","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们介绍了一种灵敏且具有选择性的侧流免疫分析法(LFIA),用于检测尼古丁的主要代谢物可替宁(COT)。可替宁(COT)被公认为是评估烟草烟雾暴露的一种优质生物标记物。LFIA 采用竞争性测定法,即 COT-BSA 捕获物与尿样中的目标 COT 竞争,以结合到与金纳米颗粒(mAb-COT-AuNPs)共轭的抗 COT 的单克隆抗体(mAb-COT)上。为了提高 LFIA-COT 的灵敏度和选择性,我们重点优化了 AuNPs 的直径、mAb-COT 的共轭以及 COT-BSA 的捕获浓度。我们的研究结果表明,与使用 20 nm AuNPs 的 LFAs 相比,使用 40 nm AuNPs 与浓度为 4 mg mL-1 的 mAb-COT 相结合的效果明显更好。在最佳条件下,LFIA-COT 能在 15 分钟内用肉眼灵敏地检测到 150 纳克 mL-1 水平的 COT。它的线性范围为 25 至 200 ng mL-1 COT,使用 ImageJ 软件分析颜色强度时,人尿液样本中 COT 的检测限(LOD)为 11.94 ng mL-1。本文所述的 LFIA 方法简单,检测 COT 所需的时间较短。它可用于临床尿样中 COT 的快速定量检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development in competitive immunoassay of a point-of-care testing for cotinine (COT) detection in urine†

We present a sensitive and selective lateral flow immunoassay (LFIA) for cotinine (COT), the primary metabolite of nicotine. COT is widely recognized as a superior biomarker to evaluate tobacco smoke exposure. The LFIA uses a competitive assay format where the COT–BSA capture competes with the target COT in urine samples for binding to the monoclonal antibody against COT (mAb–COT) conjugated with gold nanoparticles (mAb–COT–AuNPs). To improve the sensitivity and selectivity of the LFIA-COT, we focused on optimizing the diameter of AuNPs, the conjugation of mAb–COT, and the concentration of the COT–BSA capture. Our findings reveal that the utilization of 40 nm AuNPs in conjugation with a concentration of 4 mg mL−1 of mAb–COT demonstrated significantly greater efficacy compared to LFAs utilizing 20 nm AuNPs. Under the optimal conditions, the LFIA-COT demonstrated sensitive detection of COT at a level of 150 ng mL−1 within 15 min, as observed by the naked eye. It possesses a linear range of 25 to 200 ng mL−1 of COT, with the limit of detection (LOD) of 11.94 ng mL−1 in human urine samples when the color intensity is analyzed using ImageJ software. Our LFIA described here is simple and requires less time for COT detection. It can be used for the rapid and quantitative detection of COT in urine samples in clinical settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
期刊最新文献
Simultaneous determination of 78 pesticide residues and 16 mycotoxins in tsampa by an improved QuEChERS method coupled with ultra performance liquid chromatography-tandem mass spectrometry. Chemically modified graphitic carbon nitride nanosheets for the selective turn-off fluorescence detection of Al(III) ions in crabs (Brachyura). AuNPs-BP-MWCNTs-COOH-based electrochemical immunosensor for the determination of deoxynivalenol in wheat flour. A hemicyanine-based near-infrared fluorescent probe with large Stokes shift for non-invasive bioimaging of brown adipose tissue. Characterization of plasma polymerized acetonitrile film for fluorescence enhancement and its application to aptamer-based sandwich assay.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1