Mehmet Ekinci, Taha Bedir Demir, Turker Sahinkaya, Sertac Yakal, Gokhan Polat, Bulent Bayraktar
{"title":"关节镜前十字韧带重建手术中保留肱骨桡侧肌腱对术后膝关节稳定性和肌力的影响","authors":"Mehmet Ekinci, Taha Bedir Demir, Turker Sahinkaya, Sertac Yakal, Gokhan Polat, Bulent Bayraktar","doi":"10.1055/s-0044-1787829","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of our study is to evaluate preserving gracilis tendon in anterior cruciate ligament reconstruction (ACLR) surgery and its effect to the flexion of the knee joint and tibial internal rotation strength and the stability of the knee. Patients who underwent primary single-bundle arthroscopic ACLR using all-inside technique and using hamstring tendon autograft were evaluated retrospectively. Patients were divided into two groups as gracilis preserved (St) and gracilis harvested (StG) groups. The International Knee Documentation Committee (IKDC) score, Lysholm, Knee Injury and Osteoarthritis Outcome Score-Knee-related quality of life (KOOS-QOL) score, ACL-Return to Sport after Injury scale score were used to evaluate as postoperative functional scores at last follow-up. Anterior tibial translation was evaluated using the KT-1000 device. Knee joint flexion, extension, and internal rotation strength were evaluated using isokinetic dynamometer. Dynamic balance performances were measured using the Biodex Balance System. There were 24 patients in the St group and 23 patients in the StG group. Demographic data and clinical results showed no significant difference. Anteroposterior movement of the tibia was found to be significantly higher in the StG group than in the St group in measurements at 89 and 134 N, respectively (<i>p</i> = 0.01 and <0.001). No statistically significant difference was found between both standard and deep flexor and extensor and internal rotator strength. No statistically significant difference was found in the amount of total, anteroposterior, and mediolateral balance deficit between the two groups. Additional gracilis harvesting does not have a negative effect on both standard and deep knee flexion, and tibial internal rotation strength compared with the St group. Although semitendinosus and StG group showed significantly more anterior tibial translation, there was no significant difference in clinical and dynamic stability measurements.</p>","PeriodicalId":48798,"journal":{"name":"Journal of Knee Surgery","volume":" ","pages":"843-850"},"PeriodicalIF":1.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Gracilis Tendon Preservation on Postoperative Knee Joint Stability and Muscle Strength in Arthroscopic Anterior Cruciate Ligament Reconstruction Surgery.\",\"authors\":\"Mehmet Ekinci, Taha Bedir Demir, Turker Sahinkaya, Sertac Yakal, Gokhan Polat, Bulent Bayraktar\",\"doi\":\"10.1055/s-0044-1787829\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of our study is to evaluate preserving gracilis tendon in anterior cruciate ligament reconstruction (ACLR) surgery and its effect to the flexion of the knee joint and tibial internal rotation strength and the stability of the knee. Patients who underwent primary single-bundle arthroscopic ACLR using all-inside technique and using hamstring tendon autograft were evaluated retrospectively. Patients were divided into two groups as gracilis preserved (St) and gracilis harvested (StG) groups. The International Knee Documentation Committee (IKDC) score, Lysholm, Knee Injury and Osteoarthritis Outcome Score-Knee-related quality of life (KOOS-QOL) score, ACL-Return to Sport after Injury scale score were used to evaluate as postoperative functional scores at last follow-up. Anterior tibial translation was evaluated using the KT-1000 device. Knee joint flexion, extension, and internal rotation strength were evaluated using isokinetic dynamometer. Dynamic balance performances were measured using the Biodex Balance System. There were 24 patients in the St group and 23 patients in the StG group. Demographic data and clinical results showed no significant difference. Anteroposterior movement of the tibia was found to be significantly higher in the StG group than in the St group in measurements at 89 and 134 N, respectively (<i>p</i> = 0.01 and <0.001). No statistically significant difference was found between both standard and deep flexor and extensor and internal rotator strength. No statistically significant difference was found in the amount of total, anteroposterior, and mediolateral balance deficit between the two groups. Additional gracilis harvesting does not have a negative effect on both standard and deep knee flexion, and tibial internal rotation strength compared with the St group. Although semitendinosus and StG group showed significantly more anterior tibial translation, there was no significant difference in clinical and dynamic stability measurements.</p>\",\"PeriodicalId\":48798,\"journal\":{\"name\":\"Journal of Knee Surgery\",\"volume\":\" \",\"pages\":\"843-850\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Knee Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1787829\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Knee Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/s-0044-1787829","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
我们的研究旨在评估在前交叉韧带重建(ACLR)手术中保留腓肠肌肌腱及其对膝关节屈曲、胫骨内旋力量和膝关节稳定性的影响。对使用全内侧技术和腘绳肌腱自体移植进行初级单束关节镜前交叉韧带重建的患者进行了回顾性评估。患者被分为两组,即腓肠肌保留组(St)和腓肠肌移植组(StG)。国际膝关节文献委员会(IKDC)评分、Lysholm、膝关节损伤和骨关节炎结果评分-膝关节相关生活质量(KOOS-QOL)评分、前交叉韧带-损伤后恢复运动量表评分作为术后最后一次随访的功能评分。使用 KT-1000 设备评估胫骨前移。膝关节屈曲、伸展和内旋力量使用等速测力计进行评估。动态平衡性能使用 Biodex 平衡系统进行测量。St 组有 24 名患者,StG 组有 23 名患者。人口统计学数据和临床结果均无明显差异。在 89 N 和 134 N 的测量中,StG 组的胫骨前后移动明显高于 St 组(p = 0.01 和 p = 0.01)。
The Effect of Gracilis Tendon Preservation on Postoperative Knee Joint Stability and Muscle Strength in Arthroscopic Anterior Cruciate Ligament Reconstruction Surgery.
The aim of our study is to evaluate preserving gracilis tendon in anterior cruciate ligament reconstruction (ACLR) surgery and its effect to the flexion of the knee joint and tibial internal rotation strength and the stability of the knee. Patients who underwent primary single-bundle arthroscopic ACLR using all-inside technique and using hamstring tendon autograft were evaluated retrospectively. Patients were divided into two groups as gracilis preserved (St) and gracilis harvested (StG) groups. The International Knee Documentation Committee (IKDC) score, Lysholm, Knee Injury and Osteoarthritis Outcome Score-Knee-related quality of life (KOOS-QOL) score, ACL-Return to Sport after Injury scale score were used to evaluate as postoperative functional scores at last follow-up. Anterior tibial translation was evaluated using the KT-1000 device. Knee joint flexion, extension, and internal rotation strength were evaluated using isokinetic dynamometer. Dynamic balance performances were measured using the Biodex Balance System. There were 24 patients in the St group and 23 patients in the StG group. Demographic data and clinical results showed no significant difference. Anteroposterior movement of the tibia was found to be significantly higher in the StG group than in the St group in measurements at 89 and 134 N, respectively (p = 0.01 and <0.001). No statistically significant difference was found between both standard and deep flexor and extensor and internal rotator strength. No statistically significant difference was found in the amount of total, anteroposterior, and mediolateral balance deficit between the two groups. Additional gracilis harvesting does not have a negative effect on both standard and deep knee flexion, and tibial internal rotation strength compared with the St group. Although semitendinosus and StG group showed significantly more anterior tibial translation, there was no significant difference in clinical and dynamic stability measurements.
期刊介绍:
The Journal of Knee Surgery covers a range of issues relating to the orthopaedic techniques of arthroscopy, arthroplasty, and reconstructive surgery of the knee joint. In addition to original peer-review articles, this periodical provides details on emerging surgical techniques, as well as reviews and special focus sections. Topics of interest include cruciate ligament repair and reconstruction, bone grafting, cartilage regeneration, and magnetic resonance imaging.