在胚胎血管平滑肌细胞上产生肌动蛋白微丝免疫荧光模式的平滑肌抗体易于识别且具有高度自身免疫性肝炎特异性。

IF 3.4 3区 医学 Q3 IMMUNOLOGY Clinical and experimental immunology Pub Date : 2024-08-09 DOI:10.1093/cei/uxae051
Alessandro Granito, Paolo Muratori, Georgios Pappas, Marco Lenzi, Albert J Czaja, Luigi Muratori
{"title":"在胚胎血管平滑肌细胞上产生肌动蛋白微丝免疫荧光模式的平滑肌抗体易于识别且具有高度自身免疫性肝炎特异性。","authors":"Alessandro Granito, Paolo Muratori, Georgios Pappas, Marco Lenzi, Albert J Czaja, Luigi Muratori","doi":"10.1093/cei/uxae051","DOIUrl":null,"url":null,"abstract":"<p><p>Smooth muscle antibodies (SMA) with anti-microfilament actin (MF-SMA) specificity are regarded as highly specific markers of type 1 autoimmune hepatitis (AIH-1) but their recognition relying on immunofluorescence of vessel, glomeruli, and tubules (SMA-VGT pattern) in rodent kidney tissue, is restricted by operator-dependent interpretation. A gold standard method for their identification is not available. We assessed and compared the diagnostic accuracy for AIH-1 of an embryonal aorta vascular smooth muscle (VSM) cell line-based assay with those of the rodent tissue-based assay for the detection of MF-SMA pattern in AIH-1 patients and controls. Sera from 138 AIH-1 patients and 295 controls (105 primary biliary cholangitis, 40 primary sclerosing cholangitis, 50 chronic viral hepatitis, 20 alcohol-related liver disease, 40 steatotic liver disease, and 40 healthy controls) were assayed for MF-SMA and SMA-VGT using VSM-based and rodent tissue-based assays, respectively. MF-SMA and SMA-VGT were found in 96 (70%) and 87 (63%) AIH-1 patients, and 2 controls (P < 0.0001). Compared with SMA-VGT, MF-SMA showed similar specificity (99%), higher sensitivity (70% vs 63%, P = ns) and likelihood ratio for a positive test (70 vs 65). Nine (7%) AIH-1 patients were MF-SMA positive despite being SMA-VGT negative. Overall agreement between SMA-VGT and MF-SMA was 87% (kappa coefficient 0.870, [0.789-0.952]). MF-SMA were associated with higher serum γ-globulin [26 (12-55) vs 20 g/l (13-34), P < 0.005] and immunoglobulin G (IgG) levels [3155 (1296-7344) vs 2050 mg/dl (1377-3357), P < 0.002]. The easily recognizable IFL MF-SMA pattern on VSM cells strongly correlated with SMA-VGT and has an equally high specificity for AIH-1. Confirmation of these results in other laboratories would support the clinical application of the VSM cell-based assay for reliable detection of AIH-specific SMA.</p>","PeriodicalId":10268,"journal":{"name":"Clinical and experimental immunology","volume":" ","pages":"233-239"},"PeriodicalIF":3.4000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310692/pdf/","citationCount":"0","resultStr":"{\"title\":\"Easy recognition and high autoimmune hepatitis specificity of smooth muscle antibodies giving an actin microfilament immunofluorescent pattern on embryonal vascular smooth muscle cells.\",\"authors\":\"Alessandro Granito, Paolo Muratori, Georgios Pappas, Marco Lenzi, Albert J Czaja, Luigi Muratori\",\"doi\":\"10.1093/cei/uxae051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Smooth muscle antibodies (SMA) with anti-microfilament actin (MF-SMA) specificity are regarded as highly specific markers of type 1 autoimmune hepatitis (AIH-1) but their recognition relying on immunofluorescence of vessel, glomeruli, and tubules (SMA-VGT pattern) in rodent kidney tissue, is restricted by operator-dependent interpretation. A gold standard method for their identification is not available. We assessed and compared the diagnostic accuracy for AIH-1 of an embryonal aorta vascular smooth muscle (VSM) cell line-based assay with those of the rodent tissue-based assay for the detection of MF-SMA pattern in AIH-1 patients and controls. Sera from 138 AIH-1 patients and 295 controls (105 primary biliary cholangitis, 40 primary sclerosing cholangitis, 50 chronic viral hepatitis, 20 alcohol-related liver disease, 40 steatotic liver disease, and 40 healthy controls) were assayed for MF-SMA and SMA-VGT using VSM-based and rodent tissue-based assays, respectively. MF-SMA and SMA-VGT were found in 96 (70%) and 87 (63%) AIH-1 patients, and 2 controls (P < 0.0001). Compared with SMA-VGT, MF-SMA showed similar specificity (99%), higher sensitivity (70% vs 63%, P = ns) and likelihood ratio for a positive test (70 vs 65). Nine (7%) AIH-1 patients were MF-SMA positive despite being SMA-VGT negative. Overall agreement between SMA-VGT and MF-SMA was 87% (kappa coefficient 0.870, [0.789-0.952]). MF-SMA were associated with higher serum γ-globulin [26 (12-55) vs 20 g/l (13-34), P < 0.005] and immunoglobulin G (IgG) levels [3155 (1296-7344) vs 2050 mg/dl (1377-3357), P < 0.002]. The easily recognizable IFL MF-SMA pattern on VSM cells strongly correlated with SMA-VGT and has an equally high specificity for AIH-1. Confirmation of these results in other laboratories would support the clinical application of the VSM cell-based assay for reliable detection of AIH-specific SMA.</p>\",\"PeriodicalId\":10268,\"journal\":{\"name\":\"Clinical and experimental immunology\",\"volume\":\" \",\"pages\":\"233-239\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310692/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and experimental immunology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/cei/uxae051\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and experimental immunology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/cei/uxae051","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

具有抗微丝肌动蛋白(MF-SMA)特异性的平滑肌抗体(SMA)被认为是1型自身免疫性肝炎(AIH-1)的高度特异性标志物,但依靠啮齿类动物肾组织中血管、肾小球和肾小管的免疫荧光(SMA-VGT模式)来识别它们受到操作者依赖性解释的限制。我们评估并比较了基于胚胎-主动脉血管平滑肌(VSM)细胞系的检测方法与基于啮齿动物组织的检测方法对 AIH-1 患者和对照组检测 MF-SMA 模式的诊断准确性。使用基于 VSM 的检测方法和基于啮齿动物组织的检测方法分别检测了 138 名 AIH-1 患者和 295 名对照组(105 名原发性胆汁性胆管炎患者、40 名原发性硬化性胆管炎患者、50 名慢性病毒性肝炎患者、20 名酒精相关性肝病患者、40 名脂肪肝患者和 40 名健康对照组)的血清中的 MF-SMA 和 SMA-VGT 含量。在 96 名(70%)和 87 名(63%)AIH-1 患者及 2 名对照组中发现了 MF-SMA 和 SMA-VGT(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Easy recognition and high autoimmune hepatitis specificity of smooth muscle antibodies giving an actin microfilament immunofluorescent pattern on embryonal vascular smooth muscle cells.

Smooth muscle antibodies (SMA) with anti-microfilament actin (MF-SMA) specificity are regarded as highly specific markers of type 1 autoimmune hepatitis (AIH-1) but their recognition relying on immunofluorescence of vessel, glomeruli, and tubules (SMA-VGT pattern) in rodent kidney tissue, is restricted by operator-dependent interpretation. A gold standard method for their identification is not available. We assessed and compared the diagnostic accuracy for AIH-1 of an embryonal aorta vascular smooth muscle (VSM) cell line-based assay with those of the rodent tissue-based assay for the detection of MF-SMA pattern in AIH-1 patients and controls. Sera from 138 AIH-1 patients and 295 controls (105 primary biliary cholangitis, 40 primary sclerosing cholangitis, 50 chronic viral hepatitis, 20 alcohol-related liver disease, 40 steatotic liver disease, and 40 healthy controls) were assayed for MF-SMA and SMA-VGT using VSM-based and rodent tissue-based assays, respectively. MF-SMA and SMA-VGT were found in 96 (70%) and 87 (63%) AIH-1 patients, and 2 controls (P < 0.0001). Compared with SMA-VGT, MF-SMA showed similar specificity (99%), higher sensitivity (70% vs 63%, P = ns) and likelihood ratio for a positive test (70 vs 65). Nine (7%) AIH-1 patients were MF-SMA positive despite being SMA-VGT negative. Overall agreement between SMA-VGT and MF-SMA was 87% (kappa coefficient 0.870, [0.789-0.952]). MF-SMA were associated with higher serum γ-globulin [26 (12-55) vs 20 g/l (13-34), P < 0.005] and immunoglobulin G (IgG) levels [3155 (1296-7344) vs 2050 mg/dl (1377-3357), P < 0.002]. The easily recognizable IFL MF-SMA pattern on VSM cells strongly correlated with SMA-VGT and has an equally high specificity for AIH-1. Confirmation of these results in other laboratories would support the clinical application of the VSM cell-based assay for reliable detection of AIH-specific SMA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.40
自引率
2.20%
发文量
101
审稿时长
3-8 weeks
期刊介绍: Clinical & Experimental Immunology (established in 1966) is an authoritative international journal publishing high-quality research studies in translational and clinical immunology that have the potential to transform our understanding of the immunopathology of human disease and/or change clinical practice. The journal is focused on translational and clinical immunology and is among the foremost journals in this field, attracting high-quality papers from across the world. Translation is viewed as a process of applying ideas, insights and discoveries generated through scientific studies to the treatment, prevention or diagnosis of human disease. Clinical immunology has evolved as a field to encompass the application of state-of-the-art technologies such as next-generation sequencing, metagenomics and high-dimensional phenotyping to understand mechanisms that govern the outcomes of clinical trials.
期刊最新文献
A novel mouse model of myositis-associated interstitial lung disease was established by using TLR9 agonist combined with muscle homogenate. Past, Present and Future of Phase 3 Vaccine Trial Design: Rethinking Statistics for the 21st Century. Immunomodulatory effects of HYCO-3, a dual action CO-releaser/Nrf2 activator. Reduced IFNL1 and/or IFNL2, but not IFNL3 is associated with worse outcome in patients with COVID-19. A homogeneous bioluminescent inhibition immunoassay to detect anti-interferon gamma antibodies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1