{"title":"乳腺 X 射线照相术中平均腺体剂量的数据分析,以修订日本的诊断参考水平。","authors":"Toru Negishi, Yusuke Koba, Kiyomitsu Shinsho, Daisuke Fujise, Masahiro Sai, Hiroko Nishide","doi":"10.1007/s12194-024-00823-9","DOIUrl":null,"url":null,"abstract":"<p><p>Diagnostic reference level (DRL) for mammography for 2015 and 2020 has been published by J-RIME. More new dose studies are needed to revise the next DRL. In preparation for the next revision of the DRL for mammography, this study investigated data from the Japan Central Organization on Quality Assurance of Breast Cancer Screening on the mean average glandular dose (AGD) for institutional image accreditation in 2019-2023 and the relationship between the average at eligible institutions to date and the type of breast X-ray system. The 95th percentile values of the AGD distributions for the Computed Radiography (CR) and Flat Panel Detector (FPD) systems were 2.5 mGy and 2.0 mGy, respectively. Moreover, it is assumed that AGD is decreasing due to the spread of FPD systems, and it is expected that the further spread of FPD systems and systems with W/Rh target/filter will reduce AGD in future.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":" ","pages":"765-769"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Data analysis of average glandular dose in mammography toward revision of the diagnostic reference level of Japan.\",\"authors\":\"Toru Negishi, Yusuke Koba, Kiyomitsu Shinsho, Daisuke Fujise, Masahiro Sai, Hiroko Nishide\",\"doi\":\"10.1007/s12194-024-00823-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Diagnostic reference level (DRL) for mammography for 2015 and 2020 has been published by J-RIME. More new dose studies are needed to revise the next DRL. In preparation for the next revision of the DRL for mammography, this study investigated data from the Japan Central Organization on Quality Assurance of Breast Cancer Screening on the mean average glandular dose (AGD) for institutional image accreditation in 2019-2023 and the relationship between the average at eligible institutions to date and the type of breast X-ray system. The 95th percentile values of the AGD distributions for the Computed Radiography (CR) and Flat Panel Detector (FPD) systems were 2.5 mGy and 2.0 mGy, respectively. Moreover, it is assumed that AGD is decreasing due to the spread of FPD systems, and it is expected that the further spread of FPD systems and systems with W/Rh target/filter will reduce AGD in future.</p>\",\"PeriodicalId\":46252,\"journal\":{\"name\":\"Radiological Physics and Technology\",\"volume\":\" \",\"pages\":\"765-769\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiological Physics and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12194-024-00823-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-024-00823-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Data analysis of average glandular dose in mammography toward revision of the diagnostic reference level of Japan.
Diagnostic reference level (DRL) for mammography for 2015 and 2020 has been published by J-RIME. More new dose studies are needed to revise the next DRL. In preparation for the next revision of the DRL for mammography, this study investigated data from the Japan Central Organization on Quality Assurance of Breast Cancer Screening on the mean average glandular dose (AGD) for institutional image accreditation in 2019-2023 and the relationship between the average at eligible institutions to date and the type of breast X-ray system. The 95th percentile values of the AGD distributions for the Computed Radiography (CR) and Flat Panel Detector (FPD) systems were 2.5 mGy and 2.0 mGy, respectively. Moreover, it is assumed that AGD is decreasing due to the spread of FPD systems, and it is expected that the further spread of FPD systems and systems with W/Rh target/filter will reduce AGD in future.
期刊介绍:
The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.