{"title":"矮身材患者生长激素刺激试验的实用性评估。","authors":"Rahul Gupta, Aashima Dabas, Shweta Kohli, Rekha Ramot, Viveka P Jyotsna, Alpesh Goyal, Yashdeep Gupta, Rajesh Khadgawat","doi":"10.4103/ijem.ijem_326_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>To assess the performance of growth hormone stimulation tests (GHSTs) in the evaluation of short stature.</p><p><strong>Methods: </strong>It was a single-centre retrospective study carried out in children evaluated for short stature between January 2005 to March 2020. The clonidine stimulation test (CST) and glucagon stimulation test (GST) were used to assess growth hormone (GH) reserve (GST was performed only when peak GH levels were between 5 to ≤10 ng/mL on CST). A GH level of <5 ng/mL on CST or ≤10 ng/ml on both was used to corroborate GH deficiency.</p><p><strong>Results: </strong>A total of 556 children were eligible for this study. The mean (SD) age was 12.9 (3.5) years, and 66.3% were male. The peak GH level [median (IQR)] was 5.50 ng/ml (1.90 - 7.50) on CST (at 60 minutes) and 7.45 ng/ml (2.15 - 10.77) on GST (at 120 minutes). On restricting sampling to two time points, the false positive rate was 13.6% on CST (60, 90 minutes) and 11.5% on GST (120, 150 minutes). Similarly, restricting to three time points was associated with a false positive rate of 8.5% on CST (60, 90, 120 minutes) and 3.8% on GST (90, 120, 150 minutes). Using the treating clinician-determined diagnosis of GHD as a reference standard, the optimal cut-off of peak GH on CST was 7.79 ng/ml (sensitivity: 83.8%; specificity: 89.4%).</p><p><strong>Conclusion: </strong>Restricting the GH sampling to fewer time points is associated with an increase in the false positivity rate (FPR).</p>","PeriodicalId":13353,"journal":{"name":"Indian Journal of Endocrinology and Metabolism","volume":"28 2","pages":"137-144"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11189287/pdf/","citationCount":"0","resultStr":"{\"title\":\"Pragmatic Evaluation of Growth Hormone Stimulation Tests in Short Stature.\",\"authors\":\"Rahul Gupta, Aashima Dabas, Shweta Kohli, Rekha Ramot, Viveka P Jyotsna, Alpesh Goyal, Yashdeep Gupta, Rajesh Khadgawat\",\"doi\":\"10.4103/ijem.ijem_326_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>To assess the performance of growth hormone stimulation tests (GHSTs) in the evaluation of short stature.</p><p><strong>Methods: </strong>It was a single-centre retrospective study carried out in children evaluated for short stature between January 2005 to March 2020. The clonidine stimulation test (CST) and glucagon stimulation test (GST) were used to assess growth hormone (GH) reserve (GST was performed only when peak GH levels were between 5 to ≤10 ng/mL on CST). A GH level of <5 ng/mL on CST or ≤10 ng/ml on both was used to corroborate GH deficiency.</p><p><strong>Results: </strong>A total of 556 children were eligible for this study. The mean (SD) age was 12.9 (3.5) years, and 66.3% were male. The peak GH level [median (IQR)] was 5.50 ng/ml (1.90 - 7.50) on CST (at 60 minutes) and 7.45 ng/ml (2.15 - 10.77) on GST (at 120 minutes). On restricting sampling to two time points, the false positive rate was 13.6% on CST (60, 90 minutes) and 11.5% on GST (120, 150 minutes). Similarly, restricting to three time points was associated with a false positive rate of 8.5% on CST (60, 90, 120 minutes) and 3.8% on GST (90, 120, 150 minutes). Using the treating clinician-determined diagnosis of GHD as a reference standard, the optimal cut-off of peak GH on CST was 7.79 ng/ml (sensitivity: 83.8%; specificity: 89.4%).</p><p><strong>Conclusion: </strong>Restricting the GH sampling to fewer time points is associated with an increase in the false positivity rate (FPR).</p>\",\"PeriodicalId\":13353,\"journal\":{\"name\":\"Indian Journal of Endocrinology and Metabolism\",\"volume\":\"28 2\",\"pages\":\"137-144\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11189287/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Endocrinology and Metabolism\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ijem.ijem_326_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Endocrinology and Metabolism","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijem.ijem_326_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/29 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Pragmatic Evaluation of Growth Hormone Stimulation Tests in Short Stature.
Introduction: To assess the performance of growth hormone stimulation tests (GHSTs) in the evaluation of short stature.
Methods: It was a single-centre retrospective study carried out in children evaluated for short stature between January 2005 to March 2020. The clonidine stimulation test (CST) and glucagon stimulation test (GST) were used to assess growth hormone (GH) reserve (GST was performed only when peak GH levels were between 5 to ≤10 ng/mL on CST). A GH level of <5 ng/mL on CST or ≤10 ng/ml on both was used to corroborate GH deficiency.
Results: A total of 556 children were eligible for this study. The mean (SD) age was 12.9 (3.5) years, and 66.3% were male. The peak GH level [median (IQR)] was 5.50 ng/ml (1.90 - 7.50) on CST (at 60 minutes) and 7.45 ng/ml (2.15 - 10.77) on GST (at 120 minutes). On restricting sampling to two time points, the false positive rate was 13.6% on CST (60, 90 minutes) and 11.5% on GST (120, 150 minutes). Similarly, restricting to three time points was associated with a false positive rate of 8.5% on CST (60, 90, 120 minutes) and 3.8% on GST (90, 120, 150 minutes). Using the treating clinician-determined diagnosis of GHD as a reference standard, the optimal cut-off of peak GH on CST was 7.79 ng/ml (sensitivity: 83.8%; specificity: 89.4%).
Conclusion: Restricting the GH sampling to fewer time points is associated with an increase in the false positivity rate (FPR).
期刊介绍:
The Indian Journal of Endocrinology and Metabolism (IJEM) aims to function as the global face of Indian endocrinology research. It aims to act as a bridge between global and national advances in this field. The journal publishes thought-provoking editorials, comprehensive reviews, cutting-edge original research, focused brief communications and insightful letters to editor. The journal encourages authors to submit articles addressing aspects of science related to Endocrinology and Metabolism in particular Diabetology. Articles related to Clinical and Tropical endocrinology are especially encouraged. Sub-topic based Supplements are published regularly. This allows the journal to highlight issues relevant to Endocrine practitioners working in India as well as other countries. IJEM is free access in the true sense of the word, (it charges neither authors nor readers) and this enhances its global appeal.