{"title":"使用 TLD-100 评估水模型中外周剂量与钴-60 射束距离和深度的函数关系。","authors":"Habib Ahmad, Javaid Ali, Khalil Ahmad, Ghufran Biradar, Ashfaq Zaman, Yasir Uddin, Muhammad Sohail, Shahid Ali","doi":"10.1186/s43046-024-00227-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Innovations in cancer treatment have contributed to the improved survival rate of cancer patients. The cancer survival rates have been growing and nearly two third of those survivors have been exposed to clinical radiation during their treatment. The study of long-term radiation effects, especially secondary cancer induction, has become increasingly important. An accurate assessment of out-of-field/peripheral dose (PDs) is necessary to estimate the risk of second cancer after radiotherapy and the damage to the organs at risk surrounding the planning target volume. This study was designed to measure the PDs as a function of dose, distances, and depths from Telecobalt-60 (Co-60) beam in water phantom using thermoluminescent dosimeter-100 (TLD-100).</p><p><strong>Methods: </strong>The PDs were measured for Co-60 beam at specified depths of 0 cm (surface), 5 cm, 10 cm, and 15 cm outside the radiation beam at distances of 5, 10, and 13 cm away from the radiation field edge using TLD-100 (G1 cards) as detectors. These calibrated cards were placed on the acrylic disc in circular tracks. The radiation dose of 2000 mGy of Co-60 beam was applied inside 10 × 10 cm<sup>2</sup> field size at constant source to surface distance (SSD) of 80 cm.</p><p><strong>Results: </strong>The results showed maximum and minimum PDs at surface and 5 cm depth respectively at all distances from the radiation field edge. Dose distributions out of the field edge with respect to distance were isotropic. The decrease in PDs at 5 cm depth was due to dominant forward scattering of Co-60 gamma rays. The increase in PDs beyond 5 cm depth was due to increase in the irradiated volume, increase in penumbra, increase in source to axis distance (SAD), and increase in field size due to inverse square factor.</p><p><strong>Conclusion: </strong>It is concluded that the PDs depends upon depth and distance from the radiation field edge. All the measurements show PDs in the homogenous medium (water); therefore, it estimates absorbed dose to the organ at risk (OAR) adjacent to cancer tissues/planning target volume (PTV). It is suggested that PDs can be minimized by using the SAD technique, as this technique controls sources of scattered radiation like inverse square factor and effect of penumbra up-to some extent.</p>","PeriodicalId":17301,"journal":{"name":"Journal of the Egyptian National Cancer Institute","volume":"36 1","pages":"22"},"PeriodicalIF":2.1000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of peripheral dose as a function of distance and depth from cobalt-60 beam in water phantom using TLD-100.\",\"authors\":\"Habib Ahmad, Javaid Ali, Khalil Ahmad, Ghufran Biradar, Ashfaq Zaman, Yasir Uddin, Muhammad Sohail, Shahid Ali\",\"doi\":\"10.1186/s43046-024-00227-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Innovations in cancer treatment have contributed to the improved survival rate of cancer patients. The cancer survival rates have been growing and nearly two third of those survivors have been exposed to clinical radiation during their treatment. The study of long-term radiation effects, especially secondary cancer induction, has become increasingly important. An accurate assessment of out-of-field/peripheral dose (PDs) is necessary to estimate the risk of second cancer after radiotherapy and the damage to the organs at risk surrounding the planning target volume. This study was designed to measure the PDs as a function of dose, distances, and depths from Telecobalt-60 (Co-60) beam in water phantom using thermoluminescent dosimeter-100 (TLD-100).</p><p><strong>Methods: </strong>The PDs were measured for Co-60 beam at specified depths of 0 cm (surface), 5 cm, 10 cm, and 15 cm outside the radiation beam at distances of 5, 10, and 13 cm away from the radiation field edge using TLD-100 (G1 cards) as detectors. These calibrated cards were placed on the acrylic disc in circular tracks. The radiation dose of 2000 mGy of Co-60 beam was applied inside 10 × 10 cm<sup>2</sup> field size at constant source to surface distance (SSD) of 80 cm.</p><p><strong>Results: </strong>The results showed maximum and minimum PDs at surface and 5 cm depth respectively at all distances from the radiation field edge. Dose distributions out of the field edge with respect to distance were isotropic. The decrease in PDs at 5 cm depth was due to dominant forward scattering of Co-60 gamma rays. The increase in PDs beyond 5 cm depth was due to increase in the irradiated volume, increase in penumbra, increase in source to axis distance (SAD), and increase in field size due to inverse square factor.</p><p><strong>Conclusion: </strong>It is concluded that the PDs depends upon depth and distance from the radiation field edge. All the measurements show PDs in the homogenous medium (water); therefore, it estimates absorbed dose to the organ at risk (OAR) adjacent to cancer tissues/planning target volume (PTV). It is suggested that PDs can be minimized by using the SAD technique, as this technique controls sources of scattered radiation like inverse square factor and effect of penumbra up-to some extent.</p>\",\"PeriodicalId\":17301,\"journal\":{\"name\":\"Journal of the Egyptian National Cancer Institute\",\"volume\":\"36 1\",\"pages\":\"22\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Egyptian National Cancer Institute\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s43046-024-00227-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Egyptian National Cancer Institute","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43046-024-00227-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:癌症治疗的创新提高了癌症患者的生存率。癌症生存率一直在增长,其中近三分之二的幸存者在治疗期间受到过临床辐射。对长期辐射效应,尤其是继发性癌症诱导效应的研究变得越来越重要。准确评估场外/外周剂量(PDs)是估算放疗后二次癌症风险和计划靶体积周围危险器官损伤的必要条件。本研究旨在使用热释光剂量计-100(TLD-100)测量水模型中 Telecobalt-60(Co-60)光束的场外/外周剂量与剂量、距离和深度的函数关系:方法:使用 TLD-100(G1 卡)作为探测器,在辐射光束外 0 厘米(表面)、5 厘米、10 厘米和 15 厘米的指定深度以及距离辐射场边缘 5 厘米、10 厘米和 13 厘米处测量 Co-60 光束的 PD。这些经过校准的检测卡被放置在丙烯酸圆盘上,形成环形轨道。在恒定的源到表面距离(SSD)为 80 厘米时,在 10 × 10 平方厘米的辐射场内施加 2000 mGy Co-60 射束的辐射剂量:结果显示,在距离辐射场边缘的所有距离上,表面和 5 厘米深度处的辐射剂量分别最大和最小。辐射场边缘外的剂量分布与距离呈各向同性。5 厘米深度处的 PD 值降低是由于 Co-60 伽马射线的前向散射占主导地位。5 厘米深度以外的剂量分布增加是由于辐照体积增加、半影增加、源到轴距离(SAD)增加以及反平方因子导致的场大小增加:结论:PDs 取决于辐射场边缘的深度和距离。所有测量结果都显示,在均质介质(水)中存在 PDs;因此,它可以估算出邻近癌症组织/规划靶体积(PTV)的危险器官(OAR)的吸收剂量。建议使用 SAD 技术最大限度地减少 PD,因为该技术可在一定程度上控制散射辐射源,如反平方因子和半影效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of peripheral dose as a function of distance and depth from cobalt-60 beam in water phantom using TLD-100.

Background: Innovations in cancer treatment have contributed to the improved survival rate of cancer patients. The cancer survival rates have been growing and nearly two third of those survivors have been exposed to clinical radiation during their treatment. The study of long-term radiation effects, especially secondary cancer induction, has become increasingly important. An accurate assessment of out-of-field/peripheral dose (PDs) is necessary to estimate the risk of second cancer after radiotherapy and the damage to the organs at risk surrounding the planning target volume. This study was designed to measure the PDs as a function of dose, distances, and depths from Telecobalt-60 (Co-60) beam in water phantom using thermoluminescent dosimeter-100 (TLD-100).

Methods: The PDs were measured for Co-60 beam at specified depths of 0 cm (surface), 5 cm, 10 cm, and 15 cm outside the radiation beam at distances of 5, 10, and 13 cm away from the radiation field edge using TLD-100 (G1 cards) as detectors. These calibrated cards were placed on the acrylic disc in circular tracks. The radiation dose of 2000 mGy of Co-60 beam was applied inside 10 × 10 cm2 field size at constant source to surface distance (SSD) of 80 cm.

Results: The results showed maximum and minimum PDs at surface and 5 cm depth respectively at all distances from the radiation field edge. Dose distributions out of the field edge with respect to distance were isotropic. The decrease in PDs at 5 cm depth was due to dominant forward scattering of Co-60 gamma rays. The increase in PDs beyond 5 cm depth was due to increase in the irradiated volume, increase in penumbra, increase in source to axis distance (SAD), and increase in field size due to inverse square factor.

Conclusion: It is concluded that the PDs depends upon depth and distance from the radiation field edge. All the measurements show PDs in the homogenous medium (water); therefore, it estimates absorbed dose to the organ at risk (OAR) adjacent to cancer tissues/planning target volume (PTV). It is suggested that PDs can be minimized by using the SAD technique, as this technique controls sources of scattered radiation like inverse square factor and effect of penumbra up-to some extent.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
46
审稿时长
11 weeks
期刊介绍: As the official publication of the National Cancer Institute, Cairo University, the Journal of the Egyptian National Cancer Institute (JENCI) is an open access peer-reviewed journal that publishes on the latest innovations in oncology and thereby, providing academics and clinicians a leading research platform. JENCI welcomes submissions pertaining to all fields of basic, applied and clinical cancer research. Main topics of interest include: local and systemic anticancer therapy (with specific interest on applied cancer research from developing countries); experimental oncology; early cancer detection; randomized trials (including negatives ones); and key emerging fields of personalized medicine, such as molecular pathology, bioinformatics, and biotechnologies.
期刊最新文献
Assessment of podocyte detachment as a pivotal step in the development of focal segmental glomerulosclerosis. Genomic strategies for drug repurposing. Bladder cancer: a retrospective audit at a single radiation oncology unit of an academic hospital in Johannesburg, South Africa. Practical immunomodulatory landscape of glioblastoma multiforme (GBM) therapy. Association of IL-6 G-174C (rs1800795) variant with the susceptibility to hepatocellular carcinoma in patients with chronic hepatitis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1