全髋关节置换术后至少 10 年取出的重熔高交联聚乙烯内衬的体内氧化和磨损情况。

IF 3.4 2区 医学 Q1 ORTHOPEDICS Journal of Arthroplasty Pub Date : 2024-12-01 Epub Date: 2024-06-21 DOI:10.1016/j.arth.2024.06.034
Manase Nishimura, Takuya Nakamura, Hideji Nishida, Tomonori Misaki, Takao Aikawa
{"title":"全髋关节置换术后至少 10 年取出的重熔高交联聚乙烯内衬的体内氧化和磨损情况。","authors":"Manase Nishimura, Takuya Nakamura, Hideji Nishida, Tomonori Misaki, Takao Aikawa","doi":"10.1016/j.arth.2024.06.034","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With the decreasing age threshold for patients undergoing total hip arthroplasty (THA), there is an escalating demand for enhanced polyethylene durability. Although reports assessing wear in remelted highly cross-linked polyethylene (HXLPE) through radiographic imaging exist, a consensus regarding its oxidation level is lacking. This study investigated the wear, oxidation levels, and degradation of remelted HXLPE that was retrieved at least 10 years after THA.</p><p><strong>Methods: </strong>Our analysis focused on 7 cases of melted HXLPE liners retrieved ≥10 years after THA. All patients were women, who had an average age of 64 ± 6.5 years at the initial operation, and the mean postoperative period after THA was 12 years and 11 months ±1 year and 5 months. The wear conditions were measured by matching the shape analysis data obtained from a coordinate-measuring machine with a spherical model. Fourier-transform infrared spectroscopy was used to study the oxidation of polyethylene, and the polyethylene structure was evaluated using scanning electron microscopy.</p><p><strong>Results: </strong>Osteolysis was not observed in any case on X-rays, computed tomography, or intraoperative findings during revision surgery. The average oxidation index (OI) of the sliding surface under load was 0.31 ± 0.22 in the 6 cases calculated after hexane treatment, and 0.69 for one case without hexane treatment. In the 6 cases calculated after hexane treatment, the average OI of the non-load-bearing sliding surface was 0.11 ± 0.20. Average wear values were 0.33 ± 0.11 mm at 45 degrees from the equatorial direction and 0.04 ± 0.07 mm in the opposite direction. The initial structure of the polyethylene was preserved at all sites with low oxidation levels; however, in one case with stem subsidence, morphological changes and a high OI were observed.</p><p><strong>Conclusions: </strong>Long-term oxidation and wear of remelted HXLPE liners retrieved from THA patients were minimal.</p>","PeriodicalId":51077,"journal":{"name":"Journal of Arthroplasty","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty.\",\"authors\":\"Manase Nishimura, Takuya Nakamura, Hideji Nishida, Tomonori Misaki, Takao Aikawa\",\"doi\":\"10.1016/j.arth.2024.06.034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>With the decreasing age threshold for patients undergoing total hip arthroplasty (THA), there is an escalating demand for enhanced polyethylene durability. Although reports assessing wear in remelted highly cross-linked polyethylene (HXLPE) through radiographic imaging exist, a consensus regarding its oxidation level is lacking. This study investigated the wear, oxidation levels, and degradation of remelted HXLPE that was retrieved at least 10 years after THA.</p><p><strong>Methods: </strong>Our analysis focused on 7 cases of melted HXLPE liners retrieved ≥10 years after THA. All patients were women, who had an average age of 64 ± 6.5 years at the initial operation, and the mean postoperative period after THA was 12 years and 11 months ±1 year and 5 months. The wear conditions were measured by matching the shape analysis data obtained from a coordinate-measuring machine with a spherical model. Fourier-transform infrared spectroscopy was used to study the oxidation of polyethylene, and the polyethylene structure was evaluated using scanning electron microscopy.</p><p><strong>Results: </strong>Osteolysis was not observed in any case on X-rays, computed tomography, or intraoperative findings during revision surgery. The average oxidation index (OI) of the sliding surface under load was 0.31 ± 0.22 in the 6 cases calculated after hexane treatment, and 0.69 for one case without hexane treatment. In the 6 cases calculated after hexane treatment, the average OI of the non-load-bearing sliding surface was 0.11 ± 0.20. Average wear values were 0.33 ± 0.11 mm at 45 degrees from the equatorial direction and 0.04 ± 0.07 mm in the opposite direction. The initial structure of the polyethylene was preserved at all sites with low oxidation levels; however, in one case with stem subsidence, morphological changes and a high OI were observed.</p><p><strong>Conclusions: </strong>Long-term oxidation and wear of remelted HXLPE liners retrieved from THA patients were minimal.</p>\",\"PeriodicalId\":51077,\"journal\":{\"name\":\"Journal of Arthroplasty\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arthroplasty\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.arth.2024.06.034\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.arth.2024.06.034","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:随着接受全髋关节置换术(THA)的患者年龄不断降低,对增强聚乙烯耐久性的要求也在不断提高。虽然有报告称通过放射成像评估了重熔高交联聚乙烯(HXLPE)的磨损情况,但对其氧化水平还缺乏共识。本研究调查了 THA 后至少 10 年回收的重熔 HXLPE 的磨损、氧化水平和降解情况:我们的分析重点是 THA 术后≥ 10 年取回的七例熔化 HXLPE 内衬。所有患者均为女性,初次手术时的平均年龄为 64±6.5 岁,THA 术后的平均时间为 12 年 11 个月±1 年 5 个月。磨损情况是通过将坐标测量机获得的形状分析数据与球形模型进行匹配来测量的。傅立叶变换红外光谱法用于研究聚乙烯的氧化情况,扫描电子显微镜对聚乙烯结构进行了评估:任何病例的 X 射线、计算机断层扫描或翻修手术的术中检查结果均未发现骨溶解现象。经过正己烷处理的六个病例中,负载下滑动表面的平均氧化指数为 0.31 ± 0.22,而未经正己烷处理的一个病例的平均氧化指数为 0.69。在正己烷处理后计算的六个案例中,非承重滑动表面的平均氧化指数为 0.11 ± 0.20。与赤道方向成 45 度的平均磨损值为 0.33 ± 0.11 毫米,反方向为 0.04 ± 0.07 毫米。在氧化程度较低的所有地点,聚乙烯的初始结构都得到了保留;但是,在一个茎杆下沉的案例中,观察到了形态变化和较高的氧化指数:结论:从 THA 患者身上取回的重熔 HXLPE 内衬的长期氧化和磨损很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In Vivo Oxidation and Wear in Remelted Highly Cross-Linked Polyethylene Liners Retrieved at a Minimum of 10 Years After Total Hip Arthroplasty.

Background: With the decreasing age threshold for patients undergoing total hip arthroplasty (THA), there is an escalating demand for enhanced polyethylene durability. Although reports assessing wear in remelted highly cross-linked polyethylene (HXLPE) through radiographic imaging exist, a consensus regarding its oxidation level is lacking. This study investigated the wear, oxidation levels, and degradation of remelted HXLPE that was retrieved at least 10 years after THA.

Methods: Our analysis focused on 7 cases of melted HXLPE liners retrieved ≥10 years after THA. All patients were women, who had an average age of 64 ± 6.5 years at the initial operation, and the mean postoperative period after THA was 12 years and 11 months ±1 year and 5 months. The wear conditions were measured by matching the shape analysis data obtained from a coordinate-measuring machine with a spherical model. Fourier-transform infrared spectroscopy was used to study the oxidation of polyethylene, and the polyethylene structure was evaluated using scanning electron microscopy.

Results: Osteolysis was not observed in any case on X-rays, computed tomography, or intraoperative findings during revision surgery. The average oxidation index (OI) of the sliding surface under load was 0.31 ± 0.22 in the 6 cases calculated after hexane treatment, and 0.69 for one case without hexane treatment. In the 6 cases calculated after hexane treatment, the average OI of the non-load-bearing sliding surface was 0.11 ± 0.20. Average wear values were 0.33 ± 0.11 mm at 45 degrees from the equatorial direction and 0.04 ± 0.07 mm in the opposite direction. The initial structure of the polyethylene was preserved at all sites with low oxidation levels; however, in one case with stem subsidence, morphological changes and a high OI were observed.

Conclusions: Long-term oxidation and wear of remelted HXLPE liners retrieved from THA patients were minimal.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arthroplasty
Journal of Arthroplasty 医学-整形外科
CiteScore
7.00
自引率
20.00%
发文量
734
审稿时长
48 days
期刊介绍: The Journal of Arthroplasty brings together the clinical and scientific foundations for joint replacement. This peer-reviewed journal publishes original research and manuscripts of the highest quality from all areas relating to joint replacement or the treatment of its complications, including those dealing with clinical series and experience, prosthetic design, biomechanics, biomaterials, metallurgy, biologic response to arthroplasty materials in vivo and in vitro.
期刊最新文献
Systematic Review of Gender and Sex Terminology Use in Arthroplasty Research: There Is Room for Improvement. Recognizing the Sex Disparity in Surgeons Performing Total Knee Arthroplasty. Decreased Risk of Readmission and Complications With Preoperative GLP-1 Analog Use in Patients Undergoing Primary Total Joint Arthroplasty. Increased Involvement of Staphylococcus epidermidis in the Rise of Polymicrobial Periprosthetic Joint Infections. Total Knee Arthroplasty Periprosthetic Joint Infection With Concomitant Extensor Mechanism Disruption and Soft-Tissue Defect: The Knee Arthroplasty Terrible Triad.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1