Sophie Dassen, Loes Monen, Guid Oei, Massimo Mischi, Judith van Laar
{"title":"人类妊娠使用微气泡造影剂增强超声波的安全性:范围审查。","authors":"Sophie Dassen, Loes Monen, Guid Oei, Massimo Mischi, Judith van Laar","doi":"10.1055/a-2351-0747","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Successful placentation is crucial for fetal development and maintaining a healthy pregnancy. Placental insufficiency can cause a variety of obstetric complications. Despite the many efforts to enhance diagnosing placental insufficiency, no imaging technique has proven satisfactory. A promising imaging technique is contrast-enhanced ultrasound (CEUS) using microbubbles which has proven capable of (micro)vascular imaging. Its use for placental vascularization assessment in human pregnancies remains constrained by limited evidence and safety concerns. This scoping review aims to demonstrate the safety of CEUS used in human pregnancy in the published literature to date.</p><p><strong>Material and methods: </strong>A systematic search using PubMed, Medline, Embase, and Cochrane databases was performed. All studies where contrast-enhanced ultrasound was used in pregnant humans were included. Studies, where there was a planned termination of pregnancy, were excluded. To assess the safety of CEUS during pregnancy, relevant outcomes were divided into the following 3 categories; fetal outcome, maternal outcome, and pregnancy and neonatal outcomes.</p><p><strong>Results: </strong>A total of 13 articles were included, in which 256 women underwent CEUS during pregnancy. No clinically significant maternal or fetal adverse events or negative pregnancy or neonatal outcomes associated with CEUS were described.</p><p><strong>Conclusion: </strong>Based on our findings, we consider expanding the knowledge of this promising diagnostic technique in future larger clinical studies to be safe and relevant.</p>","PeriodicalId":49400,"journal":{"name":"Ultraschall in Der Medizin","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Safety of contrast-enhanced ultrasound using microbubbles in human pregnancy: A scoping review.\",\"authors\":\"Sophie Dassen, Loes Monen, Guid Oei, Massimo Mischi, Judith van Laar\",\"doi\":\"10.1055/a-2351-0747\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Successful placentation is crucial for fetal development and maintaining a healthy pregnancy. Placental insufficiency can cause a variety of obstetric complications. Despite the many efforts to enhance diagnosing placental insufficiency, no imaging technique has proven satisfactory. A promising imaging technique is contrast-enhanced ultrasound (CEUS) using microbubbles which has proven capable of (micro)vascular imaging. Its use for placental vascularization assessment in human pregnancies remains constrained by limited evidence and safety concerns. This scoping review aims to demonstrate the safety of CEUS used in human pregnancy in the published literature to date.</p><p><strong>Material and methods: </strong>A systematic search using PubMed, Medline, Embase, and Cochrane databases was performed. All studies where contrast-enhanced ultrasound was used in pregnant humans were included. Studies, where there was a planned termination of pregnancy, were excluded. To assess the safety of CEUS during pregnancy, relevant outcomes were divided into the following 3 categories; fetal outcome, maternal outcome, and pregnancy and neonatal outcomes.</p><p><strong>Results: </strong>A total of 13 articles were included, in which 256 women underwent CEUS during pregnancy. No clinically significant maternal or fetal adverse events or negative pregnancy or neonatal outcomes associated with CEUS were described.</p><p><strong>Conclusion: </strong>Based on our findings, we consider expanding the knowledge of this promising diagnostic technique in future larger clinical studies to be safe and relevant.</p>\",\"PeriodicalId\":49400,\"journal\":{\"name\":\"Ultraschall in Der Medizin\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultraschall in Der Medizin\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2351-0747\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultraschall in Der Medizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2351-0747","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
Safety of contrast-enhanced ultrasound using microbubbles in human pregnancy: A scoping review.
Introduction: Successful placentation is crucial for fetal development and maintaining a healthy pregnancy. Placental insufficiency can cause a variety of obstetric complications. Despite the many efforts to enhance diagnosing placental insufficiency, no imaging technique has proven satisfactory. A promising imaging technique is contrast-enhanced ultrasound (CEUS) using microbubbles which has proven capable of (micro)vascular imaging. Its use for placental vascularization assessment in human pregnancies remains constrained by limited evidence and safety concerns. This scoping review aims to demonstrate the safety of CEUS used in human pregnancy in the published literature to date.
Material and methods: A systematic search using PubMed, Medline, Embase, and Cochrane databases was performed. All studies where contrast-enhanced ultrasound was used in pregnant humans were included. Studies, where there was a planned termination of pregnancy, were excluded. To assess the safety of CEUS during pregnancy, relevant outcomes were divided into the following 3 categories; fetal outcome, maternal outcome, and pregnancy and neonatal outcomes.
Results: A total of 13 articles were included, in which 256 women underwent CEUS during pregnancy. No clinically significant maternal or fetal adverse events or negative pregnancy or neonatal outcomes associated with CEUS were described.
Conclusion: Based on our findings, we consider expanding the knowledge of this promising diagnostic technique in future larger clinical studies to be safe and relevant.
期刊介绍:
Ultraschall in der Medizin / European Journal of Ultrasound publishes scientific papers and contributions from a variety of disciplines on the diagnostic and therapeutic applications of ultrasound with an emphasis on clinical application. Technical papers with a physiological theme as well as the interaction between ultrasound and biological systems might also occasionally be considered for peer review and publication, provided that the translational relevance is high and the link with clinical applications is tight. The editors and the publishers reserve the right to publish selected articles online only. Authors are welcome to submit supplementary video material. Letters and comments are also accepted, promoting a vivid exchange of opinions and scientific discussions.