Stephen Mc Donald, Andrel Yoong, Piotr Skrzypiec, Alan Johnstone
{"title":"复杂肱骨近端骨折的髓内置换术:病例系列","authors":"Stephen Mc Donald, Andrel Yoong, Piotr Skrzypiec, Alan Johnstone","doi":"10.22038/ABJS.2024.74258.3437","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To assess fracture union rates using novel intramedullary plate technique. Post-operative humeral neck-shaft angles, patient range of motion and complication profile were secondary outcomes of interest.</p><p><strong>Methods: </strong>Single surgeon, retrospective case series of surgical technique at major trauma centre in Scotland. A 2.0mm mini-fragment plate was secured to the humeral head to act as an intramedullary strut during fixation in complex proximal humerus fractures. Fracture union and neck-shaft angle were assessed radiologically, whilst range of motion and complication profiles were assessed clinically.</p><p><strong>Results: </strong>Twelve patients were followed up for an average of 10 months post-operatively. All achieved bony union with a mean neck-shaft angle of 128°. Mean range of motion values were 100° forward elevation, 83° abduction, 60° internal rotation and 37° external rotation. Four patients required further surgical intervention- two for hardware prominence, one for adhesive capsulitis and one for subsequent rotator cuff failure. There were no cases of avascular necrosis or infection.</p><p><strong>Conclusion: </strong>This novel technique addresses the established biomechanical propensity of proximal humerus fractures to fail in varus collapse and screw cut-out. This method provides an alternative to arthroplasty in the most severe proximal humerus fractures and is readily adopted via standard orthopaedic kit.</p>","PeriodicalId":46704,"journal":{"name":"Archives of Bone and Joint Surgery-ABJS","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11195036/pdf/","citationCount":"0","resultStr":"{\"title\":\"Intramedullary Plating of Complex Proximal Humerus Fractures: A Case Series.\",\"authors\":\"Stephen Mc Donald, Andrel Yoong, Piotr Skrzypiec, Alan Johnstone\",\"doi\":\"10.22038/ABJS.2024.74258.3437\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To assess fracture union rates using novel intramedullary plate technique. Post-operative humeral neck-shaft angles, patient range of motion and complication profile were secondary outcomes of interest.</p><p><strong>Methods: </strong>Single surgeon, retrospective case series of surgical technique at major trauma centre in Scotland. A 2.0mm mini-fragment plate was secured to the humeral head to act as an intramedullary strut during fixation in complex proximal humerus fractures. Fracture union and neck-shaft angle were assessed radiologically, whilst range of motion and complication profiles were assessed clinically.</p><p><strong>Results: </strong>Twelve patients were followed up for an average of 10 months post-operatively. All achieved bony union with a mean neck-shaft angle of 128°. Mean range of motion values were 100° forward elevation, 83° abduction, 60° internal rotation and 37° external rotation. Four patients required further surgical intervention- two for hardware prominence, one for adhesive capsulitis and one for subsequent rotator cuff failure. There were no cases of avascular necrosis or infection.</p><p><strong>Conclusion: </strong>This novel technique addresses the established biomechanical propensity of proximal humerus fractures to fail in varus collapse and screw cut-out. This method provides an alternative to arthroplasty in the most severe proximal humerus fractures and is readily adopted via standard orthopaedic kit.</p>\",\"PeriodicalId\":46704,\"journal\":{\"name\":\"Archives of Bone and Joint Surgery-ABJS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11195036/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Bone and Joint Surgery-ABJS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22038/ABJS.2024.74258.3437\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Bone and Joint Surgery-ABJS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/ABJS.2024.74258.3437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Intramedullary Plating of Complex Proximal Humerus Fractures: A Case Series.
Objectives: To assess fracture union rates using novel intramedullary plate technique. Post-operative humeral neck-shaft angles, patient range of motion and complication profile were secondary outcomes of interest.
Methods: Single surgeon, retrospective case series of surgical technique at major trauma centre in Scotland. A 2.0mm mini-fragment plate was secured to the humeral head to act as an intramedullary strut during fixation in complex proximal humerus fractures. Fracture union and neck-shaft angle were assessed radiologically, whilst range of motion and complication profiles were assessed clinically.
Results: Twelve patients were followed up for an average of 10 months post-operatively. All achieved bony union with a mean neck-shaft angle of 128°. Mean range of motion values were 100° forward elevation, 83° abduction, 60° internal rotation and 37° external rotation. Four patients required further surgical intervention- two for hardware prominence, one for adhesive capsulitis and one for subsequent rotator cuff failure. There were no cases of avascular necrosis or infection.
Conclusion: This novel technique addresses the established biomechanical propensity of proximal humerus fractures to fail in varus collapse and screw cut-out. This method provides an alternative to arthroplasty in the most severe proximal humerus fractures and is readily adopted via standard orthopaedic kit.
期刊介绍:
The Archives of Bone and Joint Surgery (ABJS) aims to encourage a better understanding of all aspects of Orthopedic Sciences. The journal accepts scientific papers including original research, review article, short communication, case report, and letter to the editor in all fields of bone, joint, musculoskeletal surgery and related researches. The Archives of Bone and Joint Surgery (ABJS) will publish papers in all aspects of today`s modern orthopedic sciences including: Arthroscopy, Arthroplasty, Sport Medicine, Reconstruction, Hand and Upper Extremity, Pediatric Orthopedics, Spine, Trauma, Foot and Ankle, Tumor, Joint Rheumatic Disease, Skeletal Imaging, Orthopedic Physical Therapy, Rehabilitation, Orthopedic Basic Sciences (Biomechanics, Biotechnology, Biomaterial..).