Nicholas Daras, Gerald N. Nurick, Trevor J. Cloete
{"title":"皮质骨因长期储存而导致机械性能退化。","authors":"Nicholas Daras, Gerald N. Nurick, Trevor J. Cloete","doi":"10.1016/j.jmbbm.2024.106632","DOIUrl":null,"url":null,"abstract":"<div><p>Understanding the behaviour and material properties of bone is critical in predicting the failure and fracture of bones in humans. To address this, mechanical tests have traditionally been conducted to characterize bone material and this has resulted in large body of literature. However, there appears to be a lack of complete information regarding the storage protocols used for bone specimens prior to conducting mechanical tests. For example, while storage methods are well described, parameters such as the time between donor death and bone retrieval, as well as time between specimen machining and testing, are seldom reported. As biological materials undergo degradation in storage after being removed from the donor, a clear understanding of this degradation behaviour would identify critical time frames in which previously stored cortical bone specimens should be tested such that they can still be considered representative of an in-vivo condition. In this paper, the results of an investigation to determine the effects of long duration storage on the measured mechanical properties of bovine cortical bone are reported. Three different storage protocols are compared; namely machined-refrigerated, machined-frozen and frozen-machined-frozen. Degradation effects are evident for both refrigerated and frozen specimens and the results demonstrate that testing bone specimens after more than one week in storage may not provide representative in-vivo properties. In addition, specimens exhibit severe degradation after six months in storage regardless of the storage protocol.</p></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1751616124002649/pdfft?md5=0503c261f8a87d303815ce51aa0fe72f&pid=1-s2.0-S1751616124002649-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Degradation of the mechanical properties of cortical bone due to long duration storage\",\"authors\":\"Nicholas Daras, Gerald N. Nurick, Trevor J. Cloete\",\"doi\":\"10.1016/j.jmbbm.2024.106632\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Understanding the behaviour and material properties of bone is critical in predicting the failure and fracture of bones in humans. To address this, mechanical tests have traditionally been conducted to characterize bone material and this has resulted in large body of literature. However, there appears to be a lack of complete information regarding the storage protocols used for bone specimens prior to conducting mechanical tests. For example, while storage methods are well described, parameters such as the time between donor death and bone retrieval, as well as time between specimen machining and testing, are seldom reported. As biological materials undergo degradation in storage after being removed from the donor, a clear understanding of this degradation behaviour would identify critical time frames in which previously stored cortical bone specimens should be tested such that they can still be considered representative of an in-vivo condition. In this paper, the results of an investigation to determine the effects of long duration storage on the measured mechanical properties of bovine cortical bone are reported. Three different storage protocols are compared; namely machined-refrigerated, machined-frozen and frozen-machined-frozen. Degradation effects are evident for both refrigerated and frozen specimens and the results demonstrate that testing bone specimens after more than one week in storage may not provide representative in-vivo properties. In addition, specimens exhibit severe degradation after six months in storage regardless of the storage protocol.</p></div>\",\"PeriodicalId\":380,\"journal\":{\"name\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1751616124002649/pdfft?md5=0503c261f8a87d303815ce51aa0fe72f&pid=1-s2.0-S1751616124002649-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1751616124002649\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124002649","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Degradation of the mechanical properties of cortical bone due to long duration storage
Understanding the behaviour and material properties of bone is critical in predicting the failure and fracture of bones in humans. To address this, mechanical tests have traditionally been conducted to characterize bone material and this has resulted in large body of literature. However, there appears to be a lack of complete information regarding the storage protocols used for bone specimens prior to conducting mechanical tests. For example, while storage methods are well described, parameters such as the time between donor death and bone retrieval, as well as time between specimen machining and testing, are seldom reported. As biological materials undergo degradation in storage after being removed from the donor, a clear understanding of this degradation behaviour would identify critical time frames in which previously stored cortical bone specimens should be tested such that they can still be considered representative of an in-vivo condition. In this paper, the results of an investigation to determine the effects of long duration storage on the measured mechanical properties of bovine cortical bone are reported. Three different storage protocols are compared; namely machined-refrigerated, machined-frozen and frozen-machined-frozen. Degradation effects are evident for both refrigerated and frozen specimens and the results demonstrate that testing bone specimens after more than one week in storage may not provide representative in-vivo properties. In addition, specimens exhibit severe degradation after six months in storage regardless of the storage protocol.
期刊介绍:
The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials.
The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.