使用超高分辨率同位素比质谱仪高精度测量 36SF5 + 信号。

IF 1.8 3区 化学 Q4 BIOCHEMICAL RESEARCH METHODS Rapid Communications in Mass Spectrometry Pub Date : 2024-06-24 DOI:10.1002/rcm.9845
Xiang Sun, Fengtai Tong, Yongbo Peng, Huiming Bao
{"title":"使用超高分辨率同位素比质谱仪高精度测量 36SF5 + 信号。","authors":"Xiang Sun,&nbsp;Fengtai Tong,&nbsp;Yongbo Peng,&nbsp;Huiming Bao","doi":"10.1002/rcm.9845","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <h3> Rationale</h3>\n \n <p>The Δ<sup>36</sup>S standard deviation measured in a conventional isotope ratio mass spectrometer such as MAT 253 is <i>ca</i> 0.1‰ to 0.3‰. At this precision, it is difficult to resolve the origin of non-mass-dependent sulfur isotope fractionation in tropospheric sulfate aerosol and in Martian meteorites or small deviations from the canonical mass-dependent fractionation laws. Interfering ions with <i>m</i>/<i>z</i> at 131 of <sup>36</sup>SF<sub>5</sub><sup>+</sup> are suggested by the community as the cause of the poor precision, but the exact ion species has not been identified or confirmed.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Here we examined the potential interfering ions by using a Thermo Scientific ultrahigh-resolution isotope ratio mass spectrometer to measure SF<sub>6</sub> working gas and SF<sub>6</sub> gases converted from IAEA-S1/2/3 Ag<sub>2</sub>S reference materials.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>We found that there are two resolvable peaks to the right of the <sup>36</sup>SF<sub>5</sub><sup>+</sup> peak when a new filament was installed, which are <sup>186</sup>WF<sub>4</sub><sup>2+</sup> followed by <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup>. However, only the <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup> interference peak was observed after more than three days of filament use. <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup> is generated inside the instrument during the ionization process. Avoiding the interfering signals, we were able to achieve a Δ<sup>36</sup>S standard deviation of 0.046‰ (<i>n</i> = 8) for SF<sub>6</sub> zero-enrichment and 0.069‰ (<i>n</i> = 8) for overall measurement start from silver sulfide IAEA-S1.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Aging the filament with SF<sub>6</sub> gas can avoid the interference of <sup>186</sup>WF<sub>4</sub><sup>2+</sup>. Minimizing the presence of carbon-bearing compounds and avoiding the interfering signals of <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup> from <sup>36</sup>SF<sub>5</sub><sup>+</sup>, we can improve Δ<sup>36</sup>S measurement accuracy and precision, which helps to open new territories for research using quadruple sulfur isotope composition.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"38 17","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-accuracy measurement of 36SF5+ signal using an ultrahigh-resolution isotope ratio mass spectrometer\",\"authors\":\"Xiang Sun,&nbsp;Fengtai Tong,&nbsp;Yongbo Peng,&nbsp;Huiming Bao\",\"doi\":\"10.1002/rcm.9845\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <section>\\n \\n <h3> Rationale</h3>\\n \\n <p>The Δ<sup>36</sup>S standard deviation measured in a conventional isotope ratio mass spectrometer such as MAT 253 is <i>ca</i> 0.1‰ to 0.3‰. At this precision, it is difficult to resolve the origin of non-mass-dependent sulfur isotope fractionation in tropospheric sulfate aerosol and in Martian meteorites or small deviations from the canonical mass-dependent fractionation laws. Interfering ions with <i>m</i>/<i>z</i> at 131 of <sup>36</sup>SF<sub>5</sub><sup>+</sup> are suggested by the community as the cause of the poor precision, but the exact ion species has not been identified or confirmed.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Here we examined the potential interfering ions by using a Thermo Scientific ultrahigh-resolution isotope ratio mass spectrometer to measure SF<sub>6</sub> working gas and SF<sub>6</sub> gases converted from IAEA-S1/2/3 Ag<sub>2</sub>S reference materials.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>We found that there are two resolvable peaks to the right of the <sup>36</sup>SF<sub>5</sub><sup>+</sup> peak when a new filament was installed, which are <sup>186</sup>WF<sub>4</sub><sup>2+</sup> followed by <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup>. However, only the <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup> interference peak was observed after more than three days of filament use. <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup> is generated inside the instrument during the ionization process. Avoiding the interfering signals, we were able to achieve a Δ<sup>36</sup>S standard deviation of 0.046‰ (<i>n</i> = 8) for SF<sub>6</sub> zero-enrichment and 0.069‰ (<i>n</i> = 8) for overall measurement start from silver sulfide IAEA-S1.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Aging the filament with SF<sub>6</sub> gas can avoid the interference of <sup>186</sup>WF<sub>4</sub><sup>2+</sup>. Minimizing the presence of carbon-bearing compounds and avoiding the interfering signals of <sup>12</sup>C<sub>3</sub>F<sub>5</sub><sup>+</sup> from <sup>36</sup>SF<sub>5</sub><sup>+</sup>, we can improve Δ<sup>36</sup>S measurement accuracy and precision, which helps to open new territories for research using quadruple sulfur isotope composition.</p>\\n </section>\\n </div>\",\"PeriodicalId\":225,\"journal\":{\"name\":\"Rapid Communications in Mass Spectrometry\",\"volume\":\"38 17\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rapid Communications in Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9845\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9845","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

理由:在传统的同位素比质谱仪(如 MAT 253)上测量到的Δ36S 标准偏差约为 0.1‰至 0.3‰。在这种精度下,很难确定对流层硫酸盐气溶胶和火星陨石中与质量无关的硫同位素分馏的起源,或与质量有关的典型分馏定律的微小偏差。方法:在此,我们使用 Thermo Scientific 超高分辨率同位素比质谱仪测量 SF6 工作气体和从 IAEA-S1/2/3 Ag2S 参考材料转换而来的 SF6 气体,研究了潜在的干扰离子:我们发现,安装新灯丝后,在 36SF5 + 峰右侧有两个可分辨的峰,即 186WF4 2+ 峰和 12C3F5 + 峰。然而,在使用灯丝超过三天后,只观察到 12C3F5 + 干扰峰。12C3F5 + 是在电离过程中在仪器内部产生的。在避免干扰信号的情况下,SF6 零富集的 Δ36S 标准偏差为 0.046‰(n = 8),从硫化银 IAEA-S1 开始的总体测量标准偏差为 0.069‰(n = 8):用 SF6 气体老化灯丝可以避免 186WF4 2+ 的干扰。尽量减少含碳化合物的存在,避免 36SF5 + 对 12C3F5 + 信号的干扰,可以提高 Δ36S 的测量精度和准确度,有助于为利用四重硫同位素组成的研究开辟新的领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-accuracy measurement of 36SF5+ signal using an ultrahigh-resolution isotope ratio mass spectrometer

Rationale

The Δ36S standard deviation measured in a conventional isotope ratio mass spectrometer such as MAT 253 is ca 0.1‰ to 0.3‰. At this precision, it is difficult to resolve the origin of non-mass-dependent sulfur isotope fractionation in tropospheric sulfate aerosol and in Martian meteorites or small deviations from the canonical mass-dependent fractionation laws. Interfering ions with m/z at 131 of 36SF5+ are suggested by the community as the cause of the poor precision, but the exact ion species has not been identified or confirmed.

Methods

Here we examined the potential interfering ions by using a Thermo Scientific ultrahigh-resolution isotope ratio mass spectrometer to measure SF6 working gas and SF6 gases converted from IAEA-S1/2/3 Ag2S reference materials.

Results

We found that there are two resolvable peaks to the right of the 36SF5+ peak when a new filament was installed, which are 186WF42+ followed by 12C3F5+. However, only the 12C3F5+ interference peak was observed after more than three days of filament use. 12C3F5+ is generated inside the instrument during the ionization process. Avoiding the interfering signals, we were able to achieve a Δ36S standard deviation of 0.046‰ (n = 8) for SF6 zero-enrichment and 0.069‰ (n = 8) for overall measurement start from silver sulfide IAEA-S1.

Conclusions

Aging the filament with SF6 gas can avoid the interference of 186WF42+. Minimizing the presence of carbon-bearing compounds and avoiding the interfering signals of 12C3F5+ from 36SF5+, we can improve Δ36S measurement accuracy and precision, which helps to open new territories for research using quadruple sulfur isotope composition.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
5.00%
发文量
219
审稿时长
2.6 months
期刊介绍: Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.
期刊最新文献
Identification of the chemical constituents in the leaves and twigs of Nerium oleander by ultrahigh-performance liquid chromatography coupled to quadrupole Orbitrap high-resolution mass spectrometry. Investigation of the mechanism of [M–H]+ ion formation in photoionized N-alkyl-substituted thieno[3,4-c]-pyrrole-4,6-dione derivatives during higher order MSn high-resolution mass spectrometry Development and validation of a rapid HPLC-MS/MS method for simultaneous determination of cyclosporine A and tacrolimus in whole blood for routine therapeutic drug monitoring in organ transplantation The environmental and health protection commitments of Jean-François Muller: Academic and societal endeavor. A fragmentation study of disaccharide flavonoid C-glycosides using triple quadrupole mass spectrometry and its application for identification of flavonoid C-glycosides in Odontosoria chinensis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1