{"title":"用于瘘管功能测试的动静脉测压胸动图。","authors":"Veit Busch, Joachim Streis, Sandra Müller, Niklas Mueller, Felix S Seibert, Thomas Felderhoff, Timm H Westhoff","doi":"10.1159/000539885","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device with the purpose of fistula surveillance.</p><p><strong>Methods: </strong>Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analysed. Slope parameters and the areas under the curve of characteristic sections of pulse waves as well as the power spectrum of the pulse waves and their first and second derivatives were computed. Furthermore, the amplitude of volumetric change (AMP) was assessed. Duplex sonography served as a reference method.</p><p><strong>Results: </strong>In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-fistula arm (204 ± 3.4 vs. 162 ± 5.3 ms, p &lt; 0.001) was proven. Unexpectedly, pulse wave velocity apparently did not differ between both arms (7.85 vs. 8.05 m/s at the fistula/non-fistula side, p = 0.942). The inter-arm differences of the slope parameters were more pronounced in forearm than in upper arm fistulas. Finally, we showed that the inter-arm difference of AMP correlated with volume flow (r = 0.326 with p = 0.017).</p><p><strong>Conclusion: </strong>Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and the fistula vein. The analysis of those alterations has the potential to assess fistula function.</p>","PeriodicalId":17813,"journal":{"name":"Kidney & blood pressure research","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Arteriovenous Oscillometric Plethysmography for Fistula Functional Testing.\",\"authors\":\"Veit Busch, Joachim Streis, Sandra Müller, Niklas Mueller, Felix S Seibert, Thomas Felderhoff, Timm H Westhoff\",\"doi\":\"10.1159/000539885\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device with the purpose of fistula surveillance.</p><p><strong>Methods: </strong>Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analysed. Slope parameters and the areas under the curve of characteristic sections of pulse waves as well as the power spectrum of the pulse waves and their first and second derivatives were computed. Furthermore, the amplitude of volumetric change (AMP) was assessed. Duplex sonography served as a reference method.</p><p><strong>Results: </strong>In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-fistula arm (204 ± 3.4 vs. 162 ± 5.3 ms, p &lt; 0.001) was proven. Unexpectedly, pulse wave velocity apparently did not differ between both arms (7.85 vs. 8.05 m/s at the fistula/non-fistula side, p = 0.942). The inter-arm differences of the slope parameters were more pronounced in forearm than in upper arm fistulas. Finally, we showed that the inter-arm difference of AMP correlated with volume flow (r = 0.326 with p = 0.017).</p><p><strong>Conclusion: </strong>Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and the fistula vein. The analysis of those alterations has the potential to assess fistula function.</p>\",\"PeriodicalId\":17813,\"journal\":{\"name\":\"Kidney & blood pressure research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kidney & blood pressure research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000539885\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kidney & blood pressure research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000539885","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/17 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

本前瞻性观察研究的目的是通过示波仪 Vicorder® 设备评估瘘管流量对周围波形态和脉搏波速度的影响,以便对瘘管进行监测:分析了 53 名血液透析患者瘘管臂和非瘘管臂的数字化和归一化曲线。计算了脉搏波特征截面的斜率参数和曲线下面积,以及脉搏波的功率谱及其一阶和二阶导数。此外,还评估了容积变化幅度(AMP)。结果:结果:在一整套新的脉搏波参数中,臂间差异显著,与非瘘管臂相比,瘘管臂收缩期最大值显著延迟(204 ± 3.4 对 162 ± 5.3 毫秒,p<0.001)。出乎意料的是,两臂间的脉搏波速度显然没有差异(瘘管侧/非瘘管侧为 7.85 对 8.05 米/秒,p=0.942)。与上臂瘘管相比,前臂瘘管的斜率参数在两臂间的差异更为明显。最后,我们发现 AMP 的臂间差异与容积-流量相关(r= 0.326,p=0.017):结论:通过示波脉搏波分析评估的脉搏波在瘘管臂和非瘘管臂具有不同的特征。这是因为肱动脉和瘘管静脉的动静脉血流都增强了。对这些变化进行分析可评估瘘管功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Arteriovenous Oscillometric Plethysmography for Fistula Functional Testing.

Introduction: The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device with the purpose of fistula surveillance.

Methods: Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analysed. Slope parameters and the areas under the curve of characteristic sections of pulse waves as well as the power spectrum of the pulse waves and their first and second derivatives were computed. Furthermore, the amplitude of volumetric change (AMP) was assessed. Duplex sonography served as a reference method.

Results: In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-fistula arm (204 ± 3.4 vs. 162 ± 5.3 ms, p < 0.001) was proven. Unexpectedly, pulse wave velocity apparently did not differ between both arms (7.85 vs. 8.05 m/s at the fistula/non-fistula side, p = 0.942). The inter-arm differences of the slope parameters were more pronounced in forearm than in upper arm fistulas. Finally, we showed that the inter-arm difference of AMP correlated with volume flow (r = 0.326 with p = 0.017).

Conclusion: Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and the fistula vein. The analysis of those alterations has the potential to assess fistula function.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Kidney & blood pressure research
Kidney & blood pressure research 医学-泌尿学与肾脏学
CiteScore
4.80
自引率
3.60%
发文量
61
审稿时长
6-12 weeks
期刊介绍: This journal comprises both clinical and basic studies at the interface of nephrology, hypertension and cardiovascular research. The topics to be covered include the structural organization and biochemistry of the normal and diseased kidney, the molecular biology of transporters, the physiology and pathophysiology of glomerular filtration and tubular transport, endothelial and vascular smooth muscle cell function and blood pressure control, as well as water, electrolyte and mineral metabolism. Also discussed are the (patho)physiology and (patho) biochemistry of renal hormones, the molecular biology, genetics and clinical course of renal disease and hypertension, the renal elimination, action and clinical use of drugs, as well as dialysis and transplantation. Featuring peer-reviewed original papers, editorials translating basic science into patient-oriented research and disease, in depth reviews, and regular special topic sections, ''Kidney & Blood Pressure Research'' is an important source of information for researchers in nephrology and cardiovascular medicine.
期刊最新文献
Nutrition and Physical Activity in Older Adults with CKD patients: Two Sides of the Same Coin. Association Between Changes in Preoperative Serum Creatinine and Acute Kidney Injury After Cardiac Surgery: A Retrospective Cohort Study. Bidirectional Impact of Varying Severity of Acute Kidney Injury on Calcium Oxalate Stone Formation. Hypoxia activates FGF-23-ERK / MAPK signaling pathway in ischemia-reperfusion induced acute kidney injury. Nanocarrier-Based Drug Delivery Systems Targeting Kidney Diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1