揭开隐形的面纱:高密度导管在肺静脉隔离中识别分段信号的作用。

Q3 Medicine Journal of Innovations in Cardiac Rhythm Management Pub Date : 2024-06-15 eCollection Date: 2024-06-01 DOI:10.19102/icrm.2024.15063
Harini Lakshman, Ammar Ahmed, Steven Coutteau, Dipak Shah
{"title":"揭开隐形的面纱:高密度导管在肺静脉隔离中识别分段信号的作用。","authors":"Harini Lakshman, Ammar Ahmed, Steven Coutteau, Dipak Shah","doi":"10.19102/icrm.2024.15063","DOIUrl":null,"url":null,"abstract":"<p><p>The HD Grid multipolar mapping catheter has emerged as an invaluable tool for greater effectiveness of pulmonary vein isolation (PVI). In the cases described here, fractionated signals seen with the HD Grid catheter at the left atrial appendage (LAA) and left superior pulmonary vein (LSPV) junction were ablated. These signals are not likely to be visualized with conventional catheters and may cause recurrences due to incomplete PVI. The directional sensitivity limitations of bipolar electrogram recordings and the unique anatomy of the LAA-LSPV ridge further contribute to the challenge of evaluating PVI. The HD Grid catheter's ability to record bipoles parallel and perpendicular to the catheter splines and its high-density mapping capabilities provide a superior means for identifying gaps in ablation and detecting the low-voltage isthmus. Furthermore, factors such as ablation quality, catheter stability, and thickness of the LAA-LSPV ridge influence the presence of fractionated signals and the success of PVI. Incorporating preprocedural imaging modalities, such as computed tomography or magnetic resonance imaging, and real-time intracardiac echocardiography could enhance the tailored approach to address these challenges. Future developments in the HD Grid technology, including the option for contact force measurement during mapping, may offer additional insights into the nature of these signals. This case series highlights the significance of using the HD Grid catheter for a detailed interrogation of the LAA-LSPV ridge, ultimately leading to more effective PVI and improved outcomes in patients with atrial fibrillation.</p>","PeriodicalId":36299,"journal":{"name":"Journal of Innovations in Cardiac Rhythm Management","volume":"15 6","pages":"5889-5892"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11210676/pdf/","citationCount":"0","resultStr":"{\"title\":\"Uncovering the Invisible: The Role of High-density Catheters in Recognizing Fractionated Signals in Pulmonary Vein Isolation.\",\"authors\":\"Harini Lakshman, Ammar Ahmed, Steven Coutteau, Dipak Shah\",\"doi\":\"10.19102/icrm.2024.15063\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The HD Grid multipolar mapping catheter has emerged as an invaluable tool for greater effectiveness of pulmonary vein isolation (PVI). In the cases described here, fractionated signals seen with the HD Grid catheter at the left atrial appendage (LAA) and left superior pulmonary vein (LSPV) junction were ablated. These signals are not likely to be visualized with conventional catheters and may cause recurrences due to incomplete PVI. The directional sensitivity limitations of bipolar electrogram recordings and the unique anatomy of the LAA-LSPV ridge further contribute to the challenge of evaluating PVI. The HD Grid catheter's ability to record bipoles parallel and perpendicular to the catheter splines and its high-density mapping capabilities provide a superior means for identifying gaps in ablation and detecting the low-voltage isthmus. Furthermore, factors such as ablation quality, catheter stability, and thickness of the LAA-LSPV ridge influence the presence of fractionated signals and the success of PVI. Incorporating preprocedural imaging modalities, such as computed tomography or magnetic resonance imaging, and real-time intracardiac echocardiography could enhance the tailored approach to address these challenges. Future developments in the HD Grid technology, including the option for contact force measurement during mapping, may offer additional insights into the nature of these signals. This case series highlights the significance of using the HD Grid catheter for a detailed interrogation of the LAA-LSPV ridge, ultimately leading to more effective PVI and improved outcomes in patients with atrial fibrillation.</p>\",\"PeriodicalId\":36299,\"journal\":{\"name\":\"Journal of Innovations in Cardiac Rhythm Management\",\"volume\":\"15 6\",\"pages\":\"5889-5892\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11210676/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Innovations in Cardiac Rhythm Management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19102/icrm.2024.15063\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Innovations in Cardiac Rhythm Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19102/icrm.2024.15063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

HD Grid 多极绘图导管已成为提高肺静脉隔离术(PVI)有效性的重要工具。在本文描述的病例中,使用 HD Grid 导管消融了左心房阑尾(LAA)和左上肺静脉(LSPV)交界处的分化信号。传统导管不可能观察到这些信号,而且可能会因 PVI 不完整而导致复发。双极电图记录的方向灵敏度限制和 LAA-LSPV 脊的独特解剖结构进一步增加了评估 PVI 的难度。HD Grid 导管能够记录平行于和垂直于导管夹板的双极电图,其高密度绘图功能为识别消融间隙和检测低电压峡部提供了一种卓越的方法。此外,消融质量、导管稳定性和 LAA-LSPV 脊厚度等因素也会影响分馏信号的存在和 PVI 的成功。将计算机断层扫描或磁共振成像等术前成像模式和实时心内超声心动图结合起来,可以加强量身定制的方法来应对这些挑战。HD Grid 技术的未来发展,包括在绘图过程中进行接触力测量的选项,可能会让人们对这些信号的性质有更多的了解。本系列病例强调了使用 HD Grid 导管详细检查 LAA-LSPV 脊的重要性,最终可为心房颤动患者带来更有效的 PVI 和更好的治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Uncovering the Invisible: The Role of High-density Catheters in Recognizing Fractionated Signals in Pulmonary Vein Isolation.

The HD Grid multipolar mapping catheter has emerged as an invaluable tool for greater effectiveness of pulmonary vein isolation (PVI). In the cases described here, fractionated signals seen with the HD Grid catheter at the left atrial appendage (LAA) and left superior pulmonary vein (LSPV) junction were ablated. These signals are not likely to be visualized with conventional catheters and may cause recurrences due to incomplete PVI. The directional sensitivity limitations of bipolar electrogram recordings and the unique anatomy of the LAA-LSPV ridge further contribute to the challenge of evaluating PVI. The HD Grid catheter's ability to record bipoles parallel and perpendicular to the catheter splines and its high-density mapping capabilities provide a superior means for identifying gaps in ablation and detecting the low-voltage isthmus. Furthermore, factors such as ablation quality, catheter stability, and thickness of the LAA-LSPV ridge influence the presence of fractionated signals and the success of PVI. Incorporating preprocedural imaging modalities, such as computed tomography or magnetic resonance imaging, and real-time intracardiac echocardiography could enhance the tailored approach to address these challenges. Future developments in the HD Grid technology, including the option for contact force measurement during mapping, may offer additional insights into the nature of these signals. This case series highlights the significance of using the HD Grid catheter for a detailed interrogation of the LAA-LSPV ridge, ultimately leading to more effective PVI and improved outcomes in patients with atrial fibrillation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Innovations in Cardiac Rhythm Management
Journal of Innovations in Cardiac Rhythm Management Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.50
自引率
0.00%
发文量
70
期刊最新文献
Carotid Sinus Massage During Head-up Tilt Testing Can Predict the Test Outcome: Implications for Its Use as a Screening Tool in Patients with Unexplained Syncope. Challenges to Contemporary Wide Complex Tachycardia Criteria: A Single-center Case Series of 1:1 Atrial Flutter. Comparative Efficacy and Safety of Direct Oral Anticoagulants Versus Warfarin in Atrial Fibrillation Patients with Chronic Liver Disease: A Systematic Review and Meta-analysis. Implantation of an Extravascular Implantable Defibrillator Using a Substernal Lead in a Patient with Previous Cardiac Surgery. Letter from the Editor in Chief.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1