介绍并验证颅背臀角(∠CDH):妊娠头三个月胎位准确评估方法及未来人工智能应用。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Ultrasound International Open Pub Date : 2024-06-24 eCollection Date: 2024-01-01 DOI:10.1055/a-2337-0078
Ying Tan, Huaxuan Wen, Guiyan Peng, Huiying Wen, Xin Wen, Yao Jiang, Jiaqi Fan, Ying Yuan, Dandan Luo, Shengli Li
{"title":"介绍并验证颅背臀角(∠CDH):妊娠头三个月胎位准确评估方法及未来人工智能应用。","authors":"Ying Tan, Huaxuan Wen, Guiyan Peng, Huiying Wen, Xin Wen, Yao Jiang, Jiaqi Fan, Ying Yuan, Dandan Luo, Shengli Li","doi":"10.1055/a-2337-0078","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose</b>  To introduce the cranial-dorsal-hip angle (∠CDH) as a novel quantitative tool for assessing fetal position in the first trimester and to validate its feasibility for future AI applications. <b>Materials and Methods </b> 2520 first-trimester fetal NT exams with 2582 CRL images (January-August 2022) were analyzed at a tertiary hospital as the pilot group. Additionally, 1418 cases with 1450 fetal CRL images (September-December 2022) were examined for validation. Three expert sonographers defined a standard for fetal positions. ∠CDH measurements, conducted by two ultrasound technicians, were validated for consistency using Bland-Altman plots and the intra-class correlation coefficient (ICC). This method allowed for categorizing fetal positions as hyperflexion, neutral, and hyperextension based on ∠CDH. Comparative accuracy was assessed against Ioannou, Wanyonyi, and Roux methods using the weighted Kappa coefficient (k value). <b>Results </b> The pilot group comprised 2186 fetal CRL images, and the validation group included 1193 images. Measurement consistency was high (ICCs of 0.993; P<0.001). The established 95% reference range for ∠CDH in the neutral fetal position was 118.3° to 137.8°. The ∠CDH method demonstrated superior accuracy over the Ioannou, Wanyonyi, and Roux methods in both groups, with accuracy rates of 94.5% (k values: 0.874, 95%CI: 0.852-0.896) in the pilot group, and 92.6% (k values: 0.838, 95%CI: 0.806-0.871) in the validation group. <b>Conclusion</b>  The ∠CDH method has been validated as a highly reproducible and accurate technique for first-trimester fetal position assessment. This sets the stage for its potential future integration into intelligent assessment models.</p>","PeriodicalId":44852,"journal":{"name":"Ultrasound International Open","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11208982/pdf/","citationCount":"0","resultStr":"{\"title\":\"Introducing and Validating the Cranial-Dorsal-Hip Angle (∠CDH): A Method for Accurate Fetal Position Assessment in the First Trimester and Future AI Applications.\",\"authors\":\"Ying Tan, Huaxuan Wen, Guiyan Peng, Huiying Wen, Xin Wen, Yao Jiang, Jiaqi Fan, Ying Yuan, Dandan Luo, Shengli Li\",\"doi\":\"10.1055/a-2337-0078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Purpose</b>  To introduce the cranial-dorsal-hip angle (∠CDH) as a novel quantitative tool for assessing fetal position in the first trimester and to validate its feasibility for future AI applications. <b>Materials and Methods </b> 2520 first-trimester fetal NT exams with 2582 CRL images (January-August 2022) were analyzed at a tertiary hospital as the pilot group. Additionally, 1418 cases with 1450 fetal CRL images (September-December 2022) were examined for validation. Three expert sonographers defined a standard for fetal positions. ∠CDH measurements, conducted by two ultrasound technicians, were validated for consistency using Bland-Altman plots and the intra-class correlation coefficient (ICC). This method allowed for categorizing fetal positions as hyperflexion, neutral, and hyperextension based on ∠CDH. Comparative accuracy was assessed against Ioannou, Wanyonyi, and Roux methods using the weighted Kappa coefficient (k value). <b>Results </b> The pilot group comprised 2186 fetal CRL images, and the validation group included 1193 images. Measurement consistency was high (ICCs of 0.993; P<0.001). The established 95% reference range for ∠CDH in the neutral fetal position was 118.3° to 137.8°. The ∠CDH method demonstrated superior accuracy over the Ioannou, Wanyonyi, and Roux methods in both groups, with accuracy rates of 94.5% (k values: 0.874, 95%CI: 0.852-0.896) in the pilot group, and 92.6% (k values: 0.838, 95%CI: 0.806-0.871) in the validation group. <b>Conclusion</b>  The ∠CDH method has been validated as a highly reproducible and accurate technique for first-trimester fetal position assessment. This sets the stage for its potential future integration into intelligent assessment models.</p>\",\"PeriodicalId\":44852,\"journal\":{\"name\":\"Ultrasound International Open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11208982/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound International Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2337-0078\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2337-0078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的 将颅背臀角(∠CDH)作为评估头三个月胎位的新型定量工具,并验证其在未来人工智能应用中的可行性。材料与方法 以一家三甲医院为试验组,分析了 2520 例初产妇胎儿 NT 检查和 2582 张 CRL 图像(2022 年 1 月至 8 月)。此外,还对 1418 个病例的 1450 张胎儿 CRL 图像(2022 年 9 月至 12 月)进行了验证。三位专业超声技师确定了胎位的标准。由两名超声技术人员进行的∠CDH测量使用布兰-阿尔特曼图和类内相关系数(ICC)验证其一致性。这种方法可根据∠CDH 将胎位分为过屈、中立和过伸。使用加权卡帕系数(k 值)评估了与 Ioannou、Wanyonyi 和 Roux 方法的比较准确性。结果 试验组包括 2186 张胎儿 CRL 图像,验证组包括 1193 张图像。测量的一致性很高(ICCs 为 0.993;PConclusion ∠CDH 方法已被验证为一种用于初产妇胎位评估的高度可重复性和准确性的技术。这为将来将其纳入智能评估模型奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Introducing and Validating the Cranial-Dorsal-Hip Angle (∠CDH): A Method for Accurate Fetal Position Assessment in the First Trimester and Future AI Applications.

Purpose  To introduce the cranial-dorsal-hip angle (∠CDH) as a novel quantitative tool for assessing fetal position in the first trimester and to validate its feasibility for future AI applications. Materials and Methods  2520 first-trimester fetal NT exams with 2582 CRL images (January-August 2022) were analyzed at a tertiary hospital as the pilot group. Additionally, 1418 cases with 1450 fetal CRL images (September-December 2022) were examined for validation. Three expert sonographers defined a standard for fetal positions. ∠CDH measurements, conducted by two ultrasound technicians, were validated for consistency using Bland-Altman plots and the intra-class correlation coefficient (ICC). This method allowed for categorizing fetal positions as hyperflexion, neutral, and hyperextension based on ∠CDH. Comparative accuracy was assessed against Ioannou, Wanyonyi, and Roux methods using the weighted Kappa coefficient (k value). Results  The pilot group comprised 2186 fetal CRL images, and the validation group included 1193 images. Measurement consistency was high (ICCs of 0.993; P<0.001). The established 95% reference range for ∠CDH in the neutral fetal position was 118.3° to 137.8°. The ∠CDH method demonstrated superior accuracy over the Ioannou, Wanyonyi, and Roux methods in both groups, with accuracy rates of 94.5% (k values: 0.874, 95%CI: 0.852-0.896) in the pilot group, and 92.6% (k values: 0.838, 95%CI: 0.806-0.871) in the validation group. Conclusion  The ∠CDH method has been validated as a highly reproducible and accurate technique for first-trimester fetal position assessment. This sets the stage for its potential future integration into intelligent assessment models.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound International Open
Ultrasound International Open RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
0.00%
发文量
7
审稿时长
12 weeks
期刊最新文献
Congenital coarctation of the aorta: Role of peripheral vascular ultrasound in young hypertensive patients. Lung ultrasound score for the assessment of lung aeration in ARDS patients: comparison of two approaches. Pancreatic ultrasound: An update of measurements, reference values, and variations of the pancreas. Insights Into Modern Undergraduate Ultrasound Education: Prospective Comparison of Digital and Analog Teaching Resources in a Flipped Classroom Concept - The DIvAN Study. Ultrasound elastography: a brief clinical history of an evolving technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1